TR18QBL-P1111304WL Amana Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- John from Holden, MA
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Divider front of fridge hot to touch Condenser fan not working
removed back cover, removed fan motor and replaced with new one. connected new power wires. worked right away
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Douglas from Simsbury, CT
- Parts Used:
- WP10442411
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers
The upper refrigerator section was warm, but not the freezer
The refrig seemed warm so I checked the temp of some liquid with a thermometer. Readings were above 60 degrees and I knew food would spoil soon. I vacuumed the dog fur off the cooling coils underneath the machine to see if that would help. Nope. I realized cold air from the freezer was not reaching the refrig. The fan was working but no cold air was coming out. I figured a blockage either in the air duct from the refrig or in the return duct to the freezer. I didn’t see any blockage in the refrig section. I took everything out of the freezer and removed the back wall. The cooling coils were completely frozen solid with frost. Being a frost free machine, I knew there were heaters that were controlled by a timer that melted this frost away periodically and that this cycle was no longer working. I found a schematic on the web, maybe your site, and educated myself on the heater circuit. The circuit consisted of a timer, thermostat near the coils, and a cal rod heater all wired in series. The timer was easy to get to and being a mechanical device I figured it must be the culprit. I ordered one online. I checked its operation and it worked fine. Realizing time was short, I hot wired the cal rod around the thermostat and rotated the timer to its heat position. The frost melted quickly and I put the freezer back together and ordered a thermostat. I canceled the timer order. When it arrived, I installed the new thermostat and it has worked fine for the past month. A little colder than usual as I don’t yet have the settings back to where they were. I have checked the operation of the old thermostat. It’s supposed to close at 30 degrees and open at 45. I have done a continuity check on it by putting it in the freezer, letting it cool down, take it out, let it warm up and it seems to work fine. So I have doubts if I really solved the problem. Wire connections were tight and not corroded. Maybe the timer was hung up on debris that I freed by cycling it. I don’t think this is the end of the story.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Westfield, MA
- Parts Used:
- WP10442411
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
Abnormally warm temperatures in freezer/fresh food section
After unplugging the appliance I needed to thaw a large ice buildup off the evaporator cover panel before I could even remove the panel. The freezer being on the lower part of the appliance has the evaporator mounted vertically and it was 100% encapsulated in rock hard ice. It took over an hour to thaw the ice and collect all the water with a shop vacuum, since the condensate pan began to overflow.
One thawed, I checked all wiring for good connection, checked heater, defrost thermostat, timer unit with multimeter. The defrost thermostat checked out fine after putting it into another freezer for a 15 minute cooldown, but I noticed a crack in the seal and suspected internal moisture and decided to replace that part. A simple plug in of two leads to the new part after clipping it to the evaporator, replacement of the panel, and the appliance was up and running problem free.
A workbench disection of the old part confirmed my assessment, it had internal rust and water and had failed causing the defrost cycle failure.
One thawed, I checked all wiring for good connection, checked heater, defrost thermostat, timer unit with multimeter. The defrost thermostat checked out fine after putting it into another freezer for a 15 minute cooldown, but I noticed a crack in the seal and suspected internal moisture and decided to replace that part. A simple plug in of two leads to the new part after clipping it to the evaporator, replacement of the panel, and the appliance was up and running problem free.
A workbench disection of the old part confirmed my assessment, it had internal rust and water and had failed causing the defrost cycle failure.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Karl from Wellesley, MA
- Parts Used:
- 833697
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Fan was noisy - bearing had failed
It's self-explanatory. The procedure is obvious; it's just a little difficult. The only hard part is attaching the mounting brackets to the fan. If you can't tighten the mounting bolts, loosen them and reposition the brackets. You might end up mispositioning them at first, because they are hard to reach.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from Farmington Hills, MI
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Bad fan motor
Pop off six mounting screws and the ground screw. Remove the fan blade and reattach. Reinstall. Save yourself big bucks.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas from Roseville, CA
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Door light switch disintegrated
Very simple fix, remove 3 screws, two connectors to the old switch
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- dorotea from staten island, NY
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Light didnt go on
The light rocker switch wasnt working. I found the part on the web site. It was so easy. I used a screw driver to pop out the old one and pop the new one in. It took 5 min. Thanks!!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Yafa (and David) from Bothell, WA
- Parts Used:
- 8009
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Replacing the bulb in the freezer side
Removed the ice brucket,
Removed the light shield by releasing one screw using a nutdriver.
Replacing the bulb and reinstalled the light shield.
Your web site is one of the best and most helpfull service sites I ever used. Just wish that in the future you will ship parts overseas.
Removed the light shield by releasing one screw using a nutdriver.
Replacing the bulb and reinstalled the light shield.
Your web site is one of the best and most helpfull service sites I ever used. Just wish that in the future you will ship parts overseas.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- stu from richmond, VA
- Parts Used:
- W11384469
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Socket set
fridge door switch did not work
I removed the switch housing (4 screws), replacing the switch in the housing was a snap. It took 5 minutes, cost $8 and light works like new!
Why didn't I order this part and do the repair earlier? Very simple.
Why didn't I order this part and do the repair earlier? Very simple.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gail from Golden, CO
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Broke light switch while cleaning
use kitchen knife to pry out. replaced switch assemble and pressed back into place. Could not have done this with out help from previous customers. Thanks
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- craig from maple grove, MN
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
noisy fridge, perimeter of door heating up
figured out the condenser fan was kaput. Tried WD, worked for several days then gave out completely. Took off back of fridge and trained small fan on compressor while I ordered new condenser fan. The swap was easy, undid the housing bolts, stripped off the connector, reconnected and voila! works perfect.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Granada Hills, CA
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
refrigerator was overheating, condensor fan dead.
First I removed all the screws from the back cover.
2nd removed fan nut and fan blade
3rd removed fan bracket
4th I traced wire to the condenser and disconnected wires from wire nuts.
Installed existing fan brackets to new motor kit
then reconnected wire nuts to new motor cord
Reinstalled fan nut and blade,
reinstalled cover, plugged it in and BAM .WORKS PERF!
2nd removed fan nut and fan blade
3rd removed fan bracket
4th I traced wire to the condenser and disconnected wires from wire nuts.
Installed existing fan brackets to new motor kit
then reconnected wire nuts to new motor cord
Reinstalled fan nut and blade,
reinstalled cover, plugged it in and BAM .WORKS PERF!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Greensboro, NC
- Parts Used:
- 833697
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Outer case of freezer was heating up, not making ice (sometimes) turned up thermostat several times (especially freezer)
I got the product very quickly. (thank you) Looked at online instructions that were quite vague. Pulled plug.Removed the holder for the fan motor slid it out to see what I had. Removed the mounting screws (3) and slid the motor an fan blade out. I made a cut between the wires and marked the "top" wire to motor to be sure to spin in right direction. Removing fan blade hold down clamp was NOT explained at all but I noted that the shaft on the motor was threaded, so I used pliars and held the shaft white un-screwing clamp. I cleaned the fan blades with degreaser and scraped edges of opening on holder opening. Make sure to use ALL the NEW parts included with this kit when re-installing. They send them for a reason. When slpicing and connecting wires it is a 50/50 shot if you don't mark before cutting. You can connect and try plugging fridge back for moment and make sure it is blowing OUT. Put everything back together and after turning DOWN the thermostats twice, fridge is back to usual. Ice maker is cranking out ice and outside case is cool to the touch.
Note: This can be a DIRTY job especially with 4 dogs in house. Fir and grease don't mix well
Note: This can be a DIRTY job especially with 4 dogs in house. Fir and grease don't mix well
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jeff from Annandale, NJ
- Parts Used:
- WP10442411
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Frost build up in freezer
1- Remove food from freezer and store in ice chest
2- Turn off refrigerator
3- Remove freezer drawers, 2 drawers, no fastener
4- Remove freezer slide out drawer front , 2 screws
5- Remove ice cube tray holder, 2 screws
6- De-ice back panel with hair dryer / blower
7- Remove back panel in freezer, 8 screws
8- Defrost refrig coil with hair dryer / blower
9- Unplug Bimetal Thermostat, 2 wires, orang / brn
10- Remove Bimetal Thermostat from coil, 1 clip
11- Install new Bimetal Thermostat
12- Re-assemble, reverse order
2- Turn off refrigerator
3- Remove freezer drawers, 2 drawers, no fastener
4- Remove freezer slide out drawer front , 2 screws
5- Remove ice cube tray holder, 2 screws
6- De-ice back panel with hair dryer / blower
7- Remove back panel in freezer, 8 screws
8- Defrost refrig coil with hair dryer / blower
9- Unplug Bimetal Thermostat, 2 wires, orang / brn
10- Remove Bimetal Thermostat from coil, 1 clip
11- Install new Bimetal Thermostat
12- Re-assemble, reverse order
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from WILMINGTON, OH
- Parts Used:
- WPD7605106Q
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
The old seal was broken and leaking causing the freezer to ice up.
The repair was straight forward and was not hard. You do almost need 3 hands as the reinstallation of the inner door panel can be awkward. The only issue that I have is that the new seal has a poor fit. While it was received folded over on itself, this was not the problem. The seal does not expand enough on one side to fully seal the door. It also has a very weak magnet. If the magnet was stronger, then maybe it would seal better. It does still leak to some extent. The seal that was removed had a stronger magnet that the new one does. I would include a photo, but this system does not allow me to add attachments. Overall, I'm pleased with the time that it took to get the gasket, and the ease of replacement, but am not satisfied with the quality of the sealing or the strength of the magnet that holds the door closed. I would rate replace as 8 out of 10, and part quality and how it works as a 2 on a scale of 10.
Was this instruction helpful to you?
Thank you for voting!