Models > TXI21RL-P1168002WL > Instructions

TXI21RL-P1168002WL Amana Refrigerator - Instructions

Jump to:

All Instructions for the TXI21RL-P1168002WL
91 - 105 of 192
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
George from Belhaven, NC
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
cooling fan quit
Ordered new fan motor on line took out old motor and replaced with new one
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Philip from Chicopee, MA
Parts Used:
D7714408
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Burned out socket, right side of refrigerator compartment.
I was changing a defective bulb and somehow the hot lead for the socket got grounded, and arched. This made the socket defective. I simply took out the defective socket and replaced it with the new one I ordered. Working fine now. PCH
2 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Al from Tonka Bay, MN
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Socket set
Condenser Fan Failure
Partition between Freezer and Fridge was running very hot. (Warm is normal). Oiling fan did not work. The only problems encountered in the replacement were getting fan out and in through coolant lines, cut plug off to accomodate generic fan wiring, getting the screws back in without cooking your hand on a hot compressor. Unit works great!
2 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Daniel from Linthicum, MD
Parts Used:
R0151005
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Frig wasn't as cold as it should be; even with gauges cranked all the way down
Noticed fan wasn't running, remo ved, verified that it wasn't a sensor, ordered new part, installed new part...works like new. Everything is cold again!
1 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ivanka from Atlantra, GA
Parts Used:
8009
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
burned oven bulb
The hardest part was taking out original light bulb because screws on shield where hard to unscrew after all this years . The old bulb vent out leaving neck in socket. It took narrow electrical pliers to get neck out .The generic appliance bulb did not fit and had aluminum neck ,not recommended for brass sockets in ovens.Putting new light bulb in was not the problem.
3 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jeremy from State College, PA
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers, Wrench set
Refrigerator would not stay cold
Removed rear cover to see non-operating fan - removed three mounting screws on the motor that were a challenge to access. Swapped fan from old motor onto new motor - one threaded nut on the motor shaft. Spliced new fan wires into fan wires of the wiring harness and mounted with three self-tapping screws supplied with new fan motor. Replaced rear cover and plugged it in! Now the refrigerator cools like new (1981 model side-by-side Admiral)
2 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Howell, MI
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
The door gasket was very hot which is caused by an overheated expansion line that runs along the area of the door gasket. This was caused by a failed cooling fan motor.
Pulled out the refrigerator and removed the two panels from the rear of the refrigerator. Removed the fan held in by four screws and unplugged the connector. Soldered on the original connector, installed the fan to the motor and re-installed the unit into the refrigerator. Then blew out and vaccumed the condenser coils.
2 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Cherilyn from CARROLLTON, TX
Parts Used:
W11384469, 8009
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Did not work light does not come on when the door opens. Would try the light socket. It not sure how good the switch got plugged in.
By watching a video.
1 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Cecelia from Beaver Dam, WI
Parts Used:
W11384469
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
light staying on
A very cold and brittle switch in a 17 year old fridge. Used screwdrivers to pry out with some resistance Had to cut the molded plug in half and split wires, because replacement contacts were farther apart than the original. End result, works great.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William from Schwenksville, PA
Parts Used:
8009
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
oven light burnt out
1. Unscrewed glass cover on bulb
2. Removed old bulb
3. Screwed in new bulb
4. Replaced glass cover
5. Mixed drink & baked cupcakes
3 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gary from Jenkintown, PA
Parts Used:
W11384469
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Lights didn't always come on when was opened
Used a screwdriver to pry loose the old switch, swapped wires to the new switch and pushed it into the opening. Took about 2 minutes.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gregory from middle island, NY
Parts Used:
W11384469
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
light would work intermitently
removed the 2 screws that held the panel in place, had to reach up and push on locking tabs to lower trhe front of the panel. was able to then push on the locking tab of the switch to release it. removed the wires, replaced them onto the new switch, and snapped the switch into place. the rest was reverse of the uninstall process.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Fred from Watertown, NY
Parts Used:
W11384469
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
19 year old light switch broke
Great service. Unpluged old switch and pluged in new one. Works great
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
carlos from haverstraw, NY
Parts Used:
W11384469
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Replace Bad Switch
Pry old switch and pull out. Disconect two wires. Put two wires on new switch, must be inserted right and connections not loose. Put switch in, making shure wies do not come off and snap in place
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
JONATHAN from ELKINS PARK, PA
Parts Used:
W11384469
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
old switch left freezer bulb always-on
Unplug appliance. Socket wrench to unscrew two screws. Module drops down. disconnected two press-on wires by prying off with screwdriver. Removed old switch. Press-fit new switch. Reconnected two wires (color coded). Screwed module back in place. Plug in appliance.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the TXI21RL-P1168002WL