AB2225PEKS5 Amana Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Arthur from WYNNEWOOD, PA
- Parts Used:
- WPW10671238
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Rail snapped
Followed video
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from PORT JERVIS, NY
- Parts Used:
- W11396033
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
No problems
Just plugged it in
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dan from WATERVILLE, MN
- Parts Used:
- WP67006878
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
Clean the glass and asked my wife to install the glass. She is less likely to brake the glass
Removed the plastic frame, washed the frame and fridge, set new glass into the frame.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Brian from Bismarck, ND
- Parts Used:
- WPW10655367
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
drip pan was cracked
Removed rear cover, removed fan and than drip tray. install new tray and reassemblied
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from McKinney, TX
- Parts Used:
- W10619951
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver
Water pooling on the floor.
This problem is caused by a "Duckbill" rubber grommet attached to the bottom drain tube of the freezer. This duckbill opens up during the defrost cycle and allows water to drain down the "water slide" to the evaporator pan. It doesn't take much to gum the Duckbill. Once gummed up the defrost water is trapped. The Defrost Cycle eventually makes the water flow out of the coil area to the bottom of the freezer then eventually to the floor. The repair involves unplugging the unit, removing the bottom back cover with a 1/4 nut driver, pop the power clip out to give you room, reach in and pull the duckbill grommet and the water slide, then installing this replacement drain kit. This is a p trap replacement that actually fixes the root cause of this problem. A tricky part is removing the water slide, you can see the white snap that holds the slide in place. Using a small flat blade from the top releases the snap and the unit is pulled upward rather easily. This replacement drain clip snaps in the same place. If I had to do this again it wouldn't take more than two minutes to replace. Oh, one major thing, you need to manually defrost the unit. I pulled the front door off, it is held with 4 screws ... don't remove them just loosen them and it pops off easily. I pulled the bottom tray out an it gave me room to squirt hot water with a baster into the back freezer area. Eventually everything thawed out. If I had it to do over I would have waited on connecting the tube to the evaporator pan and placed the bottom of the tube into a small sauce pan or something to collect the drain water and easily dump it into the sink. I used a sponge and that took forever. BTW, just to reiterate, use this item and not that Duck Bill for replacement, this actually fixes the root cause of this problem!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gerald from COLORADO SPGS, CO
- Parts Used:
- W10121318
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
ICE BUILD UP AT BOTTOM OF FREEZER
DEFROSTED REFRIGERATOR COILS, BUT DIDN'T REPLACE THE GROMMET.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Neil from WILMINGTON, MA
- Parts Used:
- WPW10671238
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Broken center crisper rail
Lift off glass shelf and insert tabs of rail on each end , replace shelf.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Cathy from HOPATCONG, NJ
- Parts Used:
- W11384469
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Light rocker switch broke and refrigerator light couldn't go on.
I just popped out the old switch with a flat head screwdriver. Removed the connections and then installed new switch by reversing steps. Popped in back in and the light went on.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jim from Alliance, NE
- Parts Used:
- WPW10568041
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Crisper frame broke
Watched the video that was attached with part invoice. Video made it easy to perform since I’ve never done this task before.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from AUBURN, CA
- Parts Used:
- W11396033
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Refer lights not working, there are two lights and neither worked. Decided the switch was the problem.
The switch fix but did not fix the problem. I assumed the wires go on the same way as on the old switch. Is it possible if one light Burns out, the other will not work either?
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Carlton from CHICAGO, IL
- Parts Used:
- W11396033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Light out.
Popped out the old switch and replaced it with the one dying
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ronald from HUNTINGTN BCH, CA
- Parts Used:
- W11396033
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Difficulty removing old switch.
Everything went as planned except the cold temperature (freezer door switch located inside freezer) made deflection of the switch locking tab difficult to remove. Letting the switch warm up was not an option.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from NEWTON, NJ
- Parts Used:
- W10619951
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
Fridge was leaking water because of bad drain
Switched the drain out using the video tutorial
Fixed the problem
Have had no more drain issues
Fixed the problem
Have had no more drain issues
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Carolee from Spokane Valley, WA
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Light switch broke
Pried out old part with screwdriver. Unplugged. When new part came, just plugged it in and pushed the part into place.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- RALPH from PARAMUS, NJ
- Parts Used:
- W11396033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Refrigerator lamp not functioning
Had to push the light switch to get lamp to light up.
Removed power from refrig. and removed old light switch
and replaced with the one I got from Partselect. Turned power back on and was done.
Removed power from refrig. and removed old light switch
and replaced with the one I got from Partselect. Turned power back on and was done.
Was this instruction helpful to you?
Thank you for voting!