85288 (P1109012W) Amana Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Douglas from Simsbury, CT
- Parts Used:
- WP10442411
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers
The upper refrigerator section was warm, but not the freezer
The refrig seemed warm so I checked the temp of some liquid with a thermometer. Readings were above 60 degrees and I knew food would spoil soon. I vacuumed the dog fur off the cooling coils underneath the machine to see if that would help. Nope. I realized cold air from the freezer was not reaching the refrig. The fan was working but no cold air was coming out. I figured a blockage either in the air duct from the refrig or in the return duct to the freezer. I didn’t see any blockage in the refrig section. I took everything out of the freezer and removed the back wall. The cooling coils were completely frozen solid with frost. Being a frost free machine, I knew there were heaters that were controlled by a timer that melted this frost away periodically and that this cycle was no longer working. I found a schematic on the web, maybe your site, and educated myself on the heater circuit. The circuit consisted of a timer, thermostat near the coils, and a cal rod heater all wired in series. The timer was easy to get to and being a mechanical device I figured it must be the culprit. I ordered one online. I checked its operation and it worked fine. Realizing time was short, I hot wired the cal rod around the thermostat and rotated the timer to its heat position. The frost melted quickly and I put the freezer back together and ordered a thermostat. I canceled the timer order. When it arrived, I installed the new thermostat and it has worked fine for the past month. A little colder than usual as I don’t yet have the settings back to where they were. I have checked the operation of the old thermostat. It’s supposed to close at 30 degrees and open at 45. I have done a continuity check on it by putting it in the freezer, letting it cool down, take it out, let it warm up and it seems to work fine. So I have doubts if I really solved the problem. Wire connections were tight and not corroded. Maybe the timer was hung up on debris that I freed by cycling it. I don’t think this is the end of the story.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- THOMAS from WILLARD, OH
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
defective light switch
inserted a knife between the switch and the plastic interior in order to pop the switch out.
then took off the 2 wires on the old switch put them on the new switch and reinserted the switch into the plastic interior.
then took off the 2 wires on the old switch put them on the new switch and reinserted the switch into the plastic interior.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- anthony from HAVELOCK, NC
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
changed the light bulb still would not work so I figured it was the switch sure enough.
I took a chance and ordered a switch that is next to the top of the door. looked for how to remove it easily done in ten minutes works fine last long time.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Hemet, CA
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Light switch wasn't working.. As I would close the door I would notice our frig light wasn't going off...
I simply removed the old switch by gently pulling down on the old switch with a screwdriver. When it was about half way out I just gently pulled down on the old switch and it popped out... I removed the two connectors attached to the old switch by pulling on the connectors with a pliers...I tried using my fingers but wasn't able to pull the connectors off so I used pliers. It worked perfectly.. When pulling off the old connectors, make sure you attach the new switch to the same tabs on the new switch... It was very easy to do and took under 5 mins.....The light switch works perfect....P.S. You should unplug the frig while making the connection just in case....Safety first....!!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ross from Sun Lakes, AZ
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Ice cubes in bin frozen into big lumps due to water leaking into bin from icemaker. Lining of icemaker cube tray worn and damaged allowing leak.
Pull refrigerator out from wall to shut off water and power. Remove ice bin, pulling front down then out. Remove screw at bottom of icemaker, then pull down to release two clips, Pull out a couple inches to get hand behind icemaker to release wiring harness connector. (squeeze top and bottom to release clips). Remove unit. Remove wiring harness and wire bail from old unit and install on new unit. Reverse steps to install new unit. Make sure ice bin is fully inserted, or unit will not function.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Holden, MA
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Divider front of fridge hot to touch Condenser fan not working
removed back cover, removed fan motor and replaced with new one. connected new power wires. worked right away
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tonya from Grand Prairie, TX
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
Refrigerator quit cooling and the freezer wasn't freezing anything
Order the part from the Internet on Sunday, it mailed out on Monday and I received it on Tuesday. I unplugged the fan then undone 3 screws that held the fan bracket to the refrigerator pulled it out unscrewed 3 more nuts and replaced the fan on the bracket and I cut the old wire plug off the old fan and with 2 wire nuts put it on my new fan. Replaced the fan and bracket back on the refrigerator plugged it in and it works like a new refrigerator.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Raymond from Panama City Beach, FL
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Ice maker stopped working
After checking the water valves ordered new ice maker. received the part three days after ordering! Clearing out food, removing the old one and installing the new unit took under 15 minutes. Everything went fine.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gregory from GARNER, KY
- Parts Used:
- D7824706Q
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
I went by the video but my removal and installation were different than shown.
Instead of the ice maker unclipping from the wall after one 1/4" screw being removed from the bracket, I had to remove three of the 4 Phillips head screws from the ice bucket slider below the ice maker and swivel it down to allow the ice maker bracket to clear. The two 1/4" screws holding the ice maker to the wall at the top had to be removed and then the ice maker could be pulled away from the freezer wall. The rest of the instructions went according to the video and went well.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas from Roseville, CA
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Door light switch disintegrated
Very simple fix, remove 3 screws, two connectors to the old switch
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jeffery from vero beach, FL
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
water overflow,coating on tray peeling off
remove 3 screws,rotate assembly,depress lock on wire harnass connector,un plug harnass.remove old assembly,remove and transfer side cover and steel wire at front of assembly,connect harnass to new assembly,rotate into place,aling screw holes and install 3 screws.flip front steel wire down and wait for about 1 hour,first tray of ice will fall..all done.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- stu from richmond, VA
- Parts Used:
- W11384469
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Socket set
fridge door switch did not work
I removed the switch housing (4 screws), replacing the switch in the housing was a snap. It took 5 minutes, cost $8 and light works like new!
Why didn't I order this part and do the repair earlier? Very simple.
Why didn't I order this part and do the repair earlier? Very simple.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- robert from COLDSPRING, TX
- Parts Used:
- D7824706Q
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice tray filled up with water. Stopped making ice.
As per instructions. Removed parts from old ice maker, and installed them on new one, Then installed it in the freezer. Works good.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mike from Clemson, SC
- Parts Used:
- D7824706Q
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Ice maker stalled out, made excessive noise trying to evacuate completed ice cubes
There are basically three screws that hold the unit in place on the inside of the freezer. Removing them is relatively easy, and the unit is replaced with the same three screws. You do have to use the formed metal wire from your old unit, so don't throw it out! You also have to use the wiring harness from your old unit.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Raymond from Northglenn, CO
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Not making ice, and water leaking in freezer
Unplugged the power, removed old icemaker by removing 3 screws and unplugging a small wire harness
Then i moved the wire harness off the old one to the new one, moved the end cover over to new one and plugged the harness back in and screwed it back in and turned it on
ALL FIXED!
Then i moved the wire harness off the old one to the new one, moved the end cover over to new one and plugged the harness back in and screwed it back in and turned it on
ALL FIXED!
Was this instruction helpful to you?
Thank you for voting!