Models > ABB2222FED10 > Instructions

ABB2222FED10 Amana Refrigerator - Instructions

Jump to:

All Instructions for the ABB2222FED10
16 - 30 of 479
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
alvin from irmo, SC
Parts Used:
EDR4RXD1
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
easy and quick
unscrewed to removed old and screwed in new
88 of 165 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kevin from Beckley, WV
Parts Used:
W11396033
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
while closing the door, the light switch fouled, resulting in the switch breaking
I used a flat screwdriver and released the lock tab on the bottom of the light switch, and pried the switch out, being careful to not damage the plastic around the mounting place of the switch, unplugged wiring from old switch, plugged in the new one and pushed the new switch into place. Job finished light switch now working.
64 of 113 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
albert from quakertown, PA
Parts Used:
WPW10671238
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
crisper drawers were off center rail due to c.r fracture
removed old rail,lifted glass panel above and inserted new rail-voila!!done.
42 of 47 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James Richard from St. Cloud, MN
Parts Used:
W11384469
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Socket set
Light Switch broke
An easy job for smaller hands. Removed the two bolts holding the light cover. Removed two electrical connections from the old switch by pinching the retaining clip,removed the switch, snapped in the new one and re-attached the connectors. Your online illustrations helped me to know that the plastic housing for the light switch would only swing down so far and was not intended to be removed. Saved me from breaking that plastic cover's tabs. This home repair saved me more than 5 times the cost of hiring a professional to do it. Very happy homeowner.
48 of 76 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jason from Austin, TX
Parts Used:
WP628356
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Icemaker arm was broken
The tiny piece of plastic that holds the wire that shuts off the icemaker, broke early on with our fridge (after just a few months.) We superglued it, but last week it bit the dust for good.

Once I got this part, I removed the freezer door and trays, and pulled the icemaker out by removing 3 flathead screws and unplugging the cables. Laying in the freezer on the floor was a bit unconfortable, but not too bad.

Then I inspected the icemaker. There was no obvious way to remove the part without disassembling the front of the unit (where the motor is) to release the spindle and free the part, so I did that - 3 or 4 nuts was all that held it together. Once that was out, I removed the spindle, swapped out the part, and put it all back together and back in the freezer. Plugged it in and waited.

It took a while to start making ice. Like 5 hours. Now it's going pretty slow (much slower than before.) Haven't had time to look into it, but my suspicion is the rubber hose that feeds water into the icemaker is blocked with ice or kinked. In any case, we have ice now (but not a lot), and the unit shuts itself off properly. However, we went from having too much ice (thing never shut off) to too little (thing makes ice too slow), so I need to shoot for somewhere in the middle ;)
33 of 45 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Albany, OR
Parts Used:
W11384469
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
The light switch on the refridgerator broke - no light.
Once I saw the replacement part I understood how to pry out the switch with a small screwdriver. Then just unplug the old one, plug in the new one and pop it into place.

The PartSelect site made it easy to correctly identify the correct part, it was inexpensive, and the shipping was fast.

I'm very pleased!
36 of 56 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
michael from MARION, IL
Parts Used:
12002355
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
The refrigerator was freezing most products
Remove the light cover. Use a flat head screw driver to push in the tabs on the back of the program mount and pull down to expose the computer board. The Thermistor is clipped on under the vent holes on the right side. Cut both wires to remove the old thermistor strip a 1/4 inch off the remaning wires and the new thermistor wires twist both ends together crimp on the wire caps snap in the new thermistor reinstall the program board until the retainer clips snap into place, slide the light cover back on.
27 of 30 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Flagstaff, AZ
Parts Used:
WPW10128551
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
The evap motor failed (no air movement inside of refrierater
Removed screws from cover tested for power to motor found power was on to motor but motor did not work. I went to your web site was able to locate part in about 5 minutes . Even with over night shipping the part came to about $50,00, far cheaper tha a service call would have been.

Thanks John Paulsell
29 of 36 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Eric from Brooklyn, NY
Parts Used:
WPW10671238, WPW10568041
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Crisper frame and rail were damaged
I removed the glass top and then rail and frame.
I had to remove the gaskets from the old frame and put them on the new one.
The steel support and the slide mechanisms were difficult to remove. I needed a screwdriver to do this.
Some directions would have helped here.
It was easier to snap them back into the new frame.
I set the frame and then rail back into the refrigerator,
replaced the glass.
32 of 46 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Marilynn from Holland, MI
Parts Used:
EDR4RXD1
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
needed to replace filter
Turned old one until it snapped out. Replaced it with a turn.
30 of 41 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Linda from Turner, MT
Parts Used:
WPW10671238
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Broken Crisper Rail
Removed the drawers and shelf unit above the shelves. Installed the new rail and put the shelf unit and drawers back in. Less than 5 minute repair. Very fast delivery of part and reasonable pricing.
24 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Brian from Easton, PA
Parts Used:
WP67006531
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Water leaking from Water Inlet Valve
Ok, pretty easy repair when the parts are correct (first part was faulty, parts select quickly sent me a new one)

First is removal, these tubes are in there very tight, they can be pulled out but weaken the lines and it is not likely to work without severly stretching the line to the point of breakage, if you have to cut them do so carefully and take off as little tubing as possible as you need the length to feed from top to bottom.

Once you have cut all the lines, or pulled them out (I was able to get 2 out without cutting) then make sure the edges are smooth, attach the inlet valve to the plate and just push them tightly into the new valve making sure you route the lines correctly.

Turn everything on and run the water line to see if it works. If no leaks, screw it back to the refrigerator and you are good to go. Takes maybe 20 minutes at most.
24 of 29 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Oconomowoc, WI
Parts Used:
WPW10196393
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Periodic loud buzzing noise from frig damper unit
Unsnap damper louver cover using only your fingernails at bottom. Remove two phillips screws from damper cover. Remove styrofoam molded insulation. Squeeze electrical connector to release latch; unplug connector. Release latches on both sides of damper control while gently pulling on damper control unit to remove it. Install new unit by doing above steps in reverse. Damper door may move when electrics connected; keep fingers clear.
Amana would not honor our extended warranty that we paid $65 for, saying that noises are not covered. Im glad that Partselect supplied the part quick and and a great price. The frig is quiet for the first time in 2 years!
24 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Nicholas from Agawam, MA
Parts Used:
WPW10196393
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Noisy Control
Remove cover inside frig at rearwall top with screw driver. Remove phillips screws holding unit in place. Unclip connectors ,and replace in reverse order.
20 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
robert from oak forest, IL
Parts Used:
12580304
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Socket set
replace plastic wheels on refridgerator
I used board levers to do one side at a time.Kinda tricky, but you can hoist up fridge high enough to replace wheels. take your time think it out and be safe . Make sure you use saftey boards to support load to protect yourself==good luck A small mirror may help to see how the rollers alien in the supports.
24 of 36 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the ABB2222FED10
16 - 30 of 479