Refrigerator suddenly not staying cold. Freezer icing up about 1 month before.
Noticed the evaporator fan not spinning but would spin with a finger jump start. After looking up the part on the PartSelect liner parts diagram I found the installation video that really helped. After installing the fan it tested out fantastic. The fan was blowing air 10 times more than the old one. Refrigerator works great on the original econo setting.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas from Roseville, CA
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Door light switch disintegrated
Very simple fix, remove 3 screws, two connectors to the old switch
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Denise from OKLAHOMA CITY, OK
- Parts Used:
- WP2192515
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Refrigerator Shelf replacement, good fit.
The rental house I live in did not come with the original shelves for the Refrigerator. Had to strategically stack stuff on top of one another with locker shelves. Entered the model number on the site, order the best matching item, and the part that came was a perfect fit. I'll be getting another.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Samantha from JUNCTION CITY, KS
- Parts Used:
- WP2192009
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Original crisper drawer broke
Since the original drawer sides had broken off the repair was very easy. I threw the old one in the trash and inserted the new drawer in its place. The fit was perfect and I have had no issues at all. The delivery was rather speedy also. Very happy!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- stu from richmond, VA
- Parts Used:
- W11384469
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Socket set
fridge door switch did not work
I removed the switch housing (4 screws), replacing the switch in the housing was a snap. It took 5 minutes, cost $8 and light works like new!
Why didn't I order this part and do the repair earlier? Very simple.
Why didn't I order this part and do the repair earlier? Very simple.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- dorotea from staten island, NY
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Light didnt go on
The light rocker switch wasnt working. I found the part on the web site. It was so easy. I used a screw driver to pop out the old one and pop the new one in. It took 5 min. Thanks!!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gail from Golden, CO
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Broke light switch while cleaning
use kitchen knife to pry out. replaced switch assemble and pressed back into place. Could not have done this with out help from previous customers. Thanks
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from MARYLAND HTS, MO
- Parts Used:
- WPW10662129
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
freezer (later fridge too) wouldn't stay cold~
****Make are you order Capacitor & Starter relay too (we ordered separtely so had to pay shipping twice)**** Super easy just open access panel on back near compressor and remove retention clip with fingers, remove & replace both capacitor & starter, put clip and access panel back on, plug in and allow 8 hours to cool! Works like new again! Hope it goes another 10 years
Was this instruction helpful to you?
Thank you for voting!
no airflow to fresh food compartment or to freezer compartment....eveporator fan not working
Remove screws on the rear wall of the freezer. Pull the rear wall out and this gives you access to the evaporator fan assembley. Remove wires to the fan and to the defrost element to be able to move the rear wall to a position where you can work on the evaporator fan motor. The fan motor is held into place by a plastic bracket that clips onto the reverse side of the freezer rear wall. Careful not to break the plastic clips that hold the fan in place as they are brittle. The fan blade friction fits on to the fan motor shaft and is a little difficult to remove. Assemble in reverse order.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Yakov from BROOKLYN, NY
- Parts Used:
- WP2315539
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
freezer became frosty but refrigerator's camera didn'thave any coll at all.
After describing my problem PartSelect consultant emmidiately diagnost the problem and I ordered Evaporator Fan Motor. Along with purches order confirmation I got video how to install a new motor.
The hardest part was to connectthe ground wire becase space in that area was verylimited. Otherwise it was just like a walk in the park.
As soon as I installed motor and turned on the refrigirator, everything start working properly.
Thank you PartSelect, you sved me hundreds of dollars.
The hardest part was to connectthe ground wire becase space in that area was verylimited. Otherwise it was just like a walk in the park.
As soon as I installed motor and turned on the refrigirator, everything start working properly.
Thank you PartSelect, you sved me hundreds of dollars.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from HELENDALE, CA
- Parts Used:
- WPW10662129
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
freezer would not freeze
inst said,"50 pct of the time this calls for new capacitor," so we changed the capacitor. Same prob. It also said,"25 pct of the time it's the bi-metal thermostat" So we ordered it. We removed the plastic rear panel from inside the freezer comp. using small nut driver. Here we found much ICE surrounding the defrost unit, three inches thick. We thawed the whole mess. and the freezer has worked fine ever since. I think my habit of getting ice cubes from the inside container rather than from the ice cube dispenser, had kep t the freezer door open too much, interfering with the normal defrost cycle and allowing ice to build up over time so that it finally defeated the system. My new rule, "get ice cubes only from the front."
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Chad from RIDGEFIELD, NJ
- Parts Used:
- WP2315539
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers, Socket set
Bottom part of refrigerator wasn't getting cold
$80 part motor fan replaced saved me $1000 or more on new fridge.
Called in and you guys helped out
You guys are the best.
Called in and you guys helped out
You guys are the best.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- RICHARD from VENICE, FL
- Parts Used:
- WP2315539
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
Not enough cold air in refrigerator
Remove food from freezer shelf and ice maker back panel4 screws remove old motor replace with new motor reinstall all removed parts. Plug in and fan instantly came on refrigerator working great since
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Brian from BURTON, MI
- Parts Used:
- WP2315539
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Warm fridge and freezer but compressor was running. No air distribution inside fridge
I turned breaker off to fridge, it was easier than pulling fridge out in camper. I took 4 screws out of back panel that revealed the evap fan, took 2 more screws out to take fan bracket off. Unplugged fan plug. Took fan blade off the non working evap motor and put it on the new evap motor. Put all the screws back in the reverse order and flipped the breaker and air started circulating.