top freezer thawing water despencer not working
replaced the bimetal defrost thermostat & defrost timer and that seem to cure the problem found repair easy and parts were here n lest than two days very satisfied with prompt sening of parts an explanation how to repair. Thank-you!!!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mathew from Ioah City, IA
- Parts Used:
- R0161088
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Unit quit cooling -
removed the back panel inside the freezer (several small screws) with a nutdriver. used a hair dryer to melt the built up ice. replaced the thermostat and replaced the panel. very simple repair.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas from Cupertino, CA
- Parts Used:
- D7824706Q
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
The ice maker stopped making ice.
I did a few tests with the old ice maker and determined that it was the ice maker itself that was faulty. The replacement part I ordered exceeded my expectations in the time it took to get the part. I reused the arm, wire harness and clamps from the old icemaker. Then it was a simple install into the bottom freezer compartment, turning on the water supply and bingo...lots of ice cubes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Duncan from Metairie, LA
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
The Switch Broke...Absolutely Fell Apart.
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas from Ruth, MI
- Parts Used:
- D7824706Q
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
My old icemaker lost some of the nonstick surface and the ice didn't want to come out
I unhooked the wire harness from the ref. and took out three screws and pulled the old unit out. I than changed a few parts from the old icemaker to the new and reattached the new ice maker to the ref. and plugged the wire back in. everything is working fine. No problems. Also I was very happy with the ordering process. Thank you!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Linford from Cedarville, NJ
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Icemaker would not fill with water.
Removed screw under ice maker. Tilted ice maker up to remove unit from upper two screws. Disconnected plug at rear of freezer. Attached wiring harness, baler arm and cover from old to new ice maker. Reinstalled in reverse order. Had ice within one hour. Very easy fix.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joe from Rockwall, TX
- Parts Used:
- R0131577
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Not Defrosting
Disconnected power cord, Removed lower front face plate, removed one screw that helt cover over defrost timer, removed two screws that held timer, unpluged timer and removed it. Replaced old timer with new timer. Replaced timer installed two screws and replaced cover.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Kingston Springs, TN
- Parts Used:
- WPW10245167
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers, Wrench (Adjustable)
No ice from ice maker
valved water off
removed back panels from refrigerator
disconnected water supply line from solenoid
disconneceted outlet to ice maker
disconneceted outlet to water for the door
removed solenoid valve
replaced water line to the ice maker
installed new solenoid and reconnected water lines. Valved water on and pressure tested and put back panels back on. This is a very easy job and if you live in Tennessee your valve will eventually stop up. The first sign will be smaller ice cubes and then no ice cubes.
removed back panels from refrigerator
disconnected water supply line from solenoid
disconneceted outlet to ice maker
disconneceted outlet to water for the door
removed solenoid valve
replaced water line to the ice maker
installed new solenoid and reconnected water lines. Valved water on and pressure tested and put back panels back on. This is a very easy job and if you live in Tennessee your valve will eventually stop up. The first sign will be smaller ice cubes and then no ice cubes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Roxanna from Albuquerque, NM
- Parts Used:
- WP10359709Q
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Freezer gasket had tear
Loosened all retaining screws around gasket - removed old gasket - inserted new gasket and tightened screws. Little tedious (lots of screws) but very simple.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bill from KINGSPORT, TN
- Parts Used:
- W10613606
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Both compartments of the refrigerator were warm.
We came home from a long vacation to discover a warm refrigerator with its contents in various stages of decay.
Turning the freezer thermostat to its warmest setting then back to cold generated clicks, and after a few tries the compressor started and cooled the refrigerator to its normal cold temperatures. But… later the compressor again failed to start, and everything warmed back up again. With persistence and turning the thermostat up and down several times a day, we could keep the fridge cold.
It was time to order parts. We needed a new start relay and capacitor for the compressor. For our Amana ARB2214CW a start relay (WP12555902) and capacitor (WP65889-4) were listed on the first page of the Partselect parts list for my refrigerator. I ordered them, received them, removed the old capacitor and start relay (which rattled when shaken). and prepared to install my new parts. The new start relay did not match the old. The old start relay fit my wiring which had a single plug with two small female spade connectors in the plug. The new start relay required wiring with two separate female spade connectors; one the normal size and one larger. Phone calls to Partselect and to Westinghouse shed no light on the discrepancy. On the second page of the Partselect parts list was a combination of a start relay and a capacitor (W10613606) that matched my electrical connector. I could see the connection in the photograph. I ordered it and it fit. Easy peazy. That fixed the compressor start problem. Every time the freezer thermostat clicked on, the compressor started. Success.
But… from our troubleshooting we now had a thermometer the freezer, and it was obvious that the temperature difference between the cold point where the thermostat turned the compressor off and the warm point where the thermostat restarted the compressor was much too wide. In addition, the knob was hard to turn and was sticky as it turned. Oiling it fixed the sticky knob problem but not the wide temperature difference problem. I ordered a new freezer thermostat (WP67003000), received it, installed it, and all is now fine with my refrigerator. The new thermostat was physically a little different from the original, but it fit and worked.
I returned the first compressor start relay and capacitor and received a refund including the shipping charge.
Turning the freezer thermostat to its warmest setting then back to cold generated clicks, and after a few tries the compressor started and cooled the refrigerator to its normal cold temperatures. But… later the compressor again failed to start, and everything warmed back up again. With persistence and turning the thermostat up and down several times a day, we could keep the fridge cold.
It was time to order parts. We needed a new start relay and capacitor for the compressor. For our Amana ARB2214CW a start relay (WP12555902) and capacitor (WP65889-4) were listed on the first page of the Partselect parts list for my refrigerator. I ordered them, received them, removed the old capacitor and start relay (which rattled when shaken). and prepared to install my new parts. The new start relay did not match the old. The old start relay fit my wiring which had a single plug with two small female spade connectors in the plug. The new start relay required wiring with two separate female spade connectors; one the normal size and one larger. Phone calls to Partselect and to Westinghouse shed no light on the discrepancy. On the second page of the Partselect parts list was a combination of a start relay and a capacitor (W10613606) that matched my electrical connector. I could see the connection in the photograph. I ordered it and it fit. Easy peazy. That fixed the compressor start problem. Every time the freezer thermostat clicked on, the compressor started. Success.
But… from our troubleshooting we now had a thermometer the freezer, and it was obvious that the temperature difference between the cold point where the thermostat turned the compressor off and the warm point where the thermostat restarted the compressor was much too wide. In addition, the knob was hard to turn and was sticky as it turned. Oiling it fixed the sticky knob problem but not the wide temperature difference problem. I ordered a new freezer thermostat (WP67003000), received it, installed it, and all is now fine with my refrigerator. The new thermostat was physically a little different from the original, but it fit and worked.
I returned the first compressor start relay and capacitor and received a refund including the shipping charge.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ernie from Windsor, CA
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 1- 2 hours
refrigerator not cooling properly
Replaced refrigerator cooling control. No luck. Replaced freezer cooling control. No luck. Coils were icing up. Unplugged frig and allowed coils to defrost. After more poking around, found that condenser fan was not spinning. Touch it and it'd start. That was definitely in need of replacement. Replacement was easy. Refrigerator is now running as it should.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Carl from RIVERSIDE, CA
- Parts Used:
- 8009
- Difficulty Level:
- Very Difficult
- Total Repair Time:
- More than 2 hours
- Tools:
- Screw drivers
light bulb in water ice freezer door went bad
I didn't. Don't know how to get to light bulb to change it for this specific model
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Edward from Florance, MT
- Parts Used:
- WPD7749401
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Auger in the ice tray not turning
Removed ice container, replaced end cap that holds Auger shaft that connects to shaft that turns the Auger. End cap plastic nubs wear where it makes contact to the turning stub. Removing a few screws on the front of ice container allows the Auger shaft to slide forward and away from the end cap. Maneuver end cap from shaft, replace using same maneuver and that is it.
Pretty easy, even for a novice like me. A $6.00 end cap verses the whole assembly at around $70.00
I'm pleased.......
Pretty easy, even for a novice like me. A $6.00 end cap verses the whole assembly at around $70.00
I'm pleased.......
Was this instruction helpful to you?
Thank you for voting!
Would Not Cool
I removed the panel to gain access to the condenser and found it to be a solid block of ice. I ordered the 2 parts, I suspected and they arrived in 3 days. I replaced the parts and let it run for 48 hours. All is well and the frige gets colder than before.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dave from Manchester Center, VT
- Parts Used:
- W11384469
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Socket set
Refrigerator light would not stay on
Removed the 2 screws holding the light bulb shield, then the 4 uolding the metal panel. Unplugged the olw door switch and replaced.
reassembled the pieces.
reassembled the pieces.
Was this instruction helpful to you?
Thank you for voting!