- Customer:
- Bill from KINGSPORT, TN
- Parts Used:
- W10613606
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Both compartments of the refrigerator were warm.
We came home from a long vacation to discover a warm refrigerator with its contents in various stages of decay.
Turning the freezer thermostat to its warmest setting then back to cold generated clicks, and after a few tries the compressor started and cooled the refrigerator to its normal cold temperatures. But… later the compressor again failed to start, and everything warmed back up again. With persistence and turning the thermostat up and down several times a day, we could keep the fridge cold.
It was time to order parts. We needed a new start relay and capacitor for the compressor. For our Amana ARB2214CW a start relay (WP12555902) and capacitor (WP65889-4) were listed on the first page of the Partselect parts list for my refrigerator. I ordered them, received them, removed the old capacitor and start relay (which rattled when shaken). and prepared to install my new parts. The new start relay did not match the old. The old start relay fit my wiring which had a single plug with two small female spade connectors in the plug. The new start relay required wiring with two separate female spade connectors; one the normal size and one larger. Phone calls to Partselect and to Westinghouse shed no light on the discrepancy. On the second page of the Partselect parts list was a combination of a start relay and a capacitor (W10613606) that matched my electrical connector. I could see the connection in the photograph. I ordered it and it fit. Easy peazy. That fixed the compressor start problem. Every time the freezer thermostat clicked on, the compressor started. Success.
But… from our troubleshooting we now had a thermometer the freezer, and it was obvious that the temperature difference between the cold point where the thermostat turned the compressor off and the warm point where the thermostat restarted the compressor was much too wide. In addition, the knob was hard to turn and was sticky as it turned. Oiling it fixed the sticky knob problem but not the wide temperature difference problem. I ordered a new freezer thermostat (WP67003000), received it, installed it, and all is now fine with my refrigerator. The new thermostat was physically a little different from the original, but it fit and worked.
I returned the first compressor start relay and capacitor and received a refund including the shipping charge.
Turning the freezer thermostat to its warmest setting then back to cold generated clicks, and after a few tries the compressor started and cooled the refrigerator to its normal cold temperatures. But… later the compressor again failed to start, and everything warmed back up again. With persistence and turning the thermostat up and down several times a day, we could keep the fridge cold.
It was time to order parts. We needed a new start relay and capacitor for the compressor. For our Amana ARB2214CW a start relay (WP12555902) and capacitor (WP65889-4) were listed on the first page of the Partselect parts list for my refrigerator. I ordered them, received them, removed the old capacitor and start relay (which rattled when shaken). and prepared to install my new parts. The new start relay did not match the old. The old start relay fit my wiring which had a single plug with two small female spade connectors in the plug. The new start relay required wiring with two separate female spade connectors; one the normal size and one larger. Phone calls to Partselect and to Westinghouse shed no light on the discrepancy. On the second page of the Partselect parts list was a combination of a start relay and a capacitor (W10613606) that matched my electrical connector. I could see the connection in the photograph. I ordered it and it fit. Easy peazy. That fixed the compressor start problem. Every time the freezer thermostat clicked on, the compressor started. Success.
But… from our troubleshooting we now had a thermometer the freezer, and it was obvious that the temperature difference between the cold point where the thermostat turned the compressor off and the warm point where the thermostat restarted the compressor was much too wide. In addition, the knob was hard to turn and was sticky as it turned. Oiling it fixed the sticky knob problem but not the wide temperature difference problem. I ordered a new freezer thermostat (WP67003000), received it, installed it, and all is now fine with my refrigerator. The new thermostat was physically a little different from the original, but it fit and worked.
I returned the first compressor start relay and capacitor and received a refund including the shipping charge.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- WADE from PILOT MTN, NC
- Parts Used:
- WP67003426
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers, Screw drivers, Socket set
COILS WAS ICING ON REFRIGRATOR SOLID ICED FOUND ENTIRE COILS
CHECK DEFROST THERMOSTAT WITH VOLT OHM METER AND FOUND THERMOSTAT BAD ALSO OHMED OUT HEATER AND HEATER CHECKED OK INSTALLED HEAT SRINK CONNECTORS ON NEW DEFROST THERMOSTAT PUT SYSTEM BACK INTO O
PRATION ALSO CHANGED WATER FILTER ON REFERGRATOR
SYSTEM WORKING OK AND NO ICING OF COILS THANKS WADE BOYLES
PRATION ALSO CHANGED WATER FILTER ON REFERGRATOR
SYSTEM WORKING OK AND NO ICING OF COILS THANKS WADE BOYLES
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Carl from EAST LYME, CT
- Parts Used:
- WP67003426
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Refrigerator would not cool, while the freezer kept food frozen and the ice maker worked fine. Also, noticed frost build up at the rear of the freezer compartment
First, turned off the circuit breaker. Then: 1. Removed all food, , wire sliding baskets, and the ice bin.
2. Removed ice maker by removing the electrical connector from the socket in the rear panel, removed the single bottom screw with a 1/4” nut driver, loosened the 2 top screws with a 1/4” nut driver, and lifting the unit up and off the 2 loosened screws.
3. Removed the freezer door by loosening the 4 screws( 2 on each side) with a 1/4” nut driver and then lifting the door face off the loosened screws.
4. The next task is to remove the panel at the rear of the freezer compartment: use a flat blade screw driver to compress the side clips that hold the ice maker electrical socket, pushing it into the space behind the rear panel, then removing the rear plastic cover in the center of the rear panel, and finally removing the thermistor cover on the right rear upper corner of the rear panel( separate the thermistor from this piece, threading it through the slot in the top of the plastic cover.
Now, the rear panel can be removed by removing the 4 1/4”” hex head screws with the nut driver and gently easing the panel from its position.
5. Now comes the hard part: the defrost thermostat and most of the surrounding “plumbing” was encased in ice. I used a hair dryer to melt the ice, which created an overflow of water drawing into the collection pan; get ready to mop up this water.
6. With ALL the ice melted( this took over an hour), I simply cut the 2 wires, stripped the feed ends, removed the defective unit, clipped the new thermostat to the copper tube where the old unit was clipped, cut excess wire/stripped the new wires and used 2 orange wire nuts to connect each wire.
Now all the parts and pieces can be reinstalled in the reverse order
2. Removed ice maker by removing the electrical connector from the socket in the rear panel, removed the single bottom screw with a 1/4” nut driver, loosened the 2 top screws with a 1/4” nut driver, and lifting the unit up and off the 2 loosened screws.
3. Removed the freezer door by loosening the 4 screws( 2 on each side) with a 1/4” nut driver and then lifting the door face off the loosened screws.
4. The next task is to remove the panel at the rear of the freezer compartment: use a flat blade screw driver to compress the side clips that hold the ice maker electrical socket, pushing it into the space behind the rear panel, then removing the rear plastic cover in the center of the rear panel, and finally removing the thermistor cover on the right rear upper corner of the rear panel( separate the thermistor from this piece, threading it through the slot in the top of the plastic cover.
Now, the rear panel can be removed by removing the 4 1/4”” hex head screws with the nut driver and gently easing the panel from its position.
5. Now comes the hard part: the defrost thermostat and most of the surrounding “plumbing” was encased in ice. I used a hair dryer to melt the ice, which created an overflow of water drawing into the collection pan; get ready to mop up this water.
6. With ALL the ice melted( this took over an hour), I simply cut the 2 wires, stripped the feed ends, removed the defective unit, clipped the new thermostat to the copper tube where the old unit was clipped, cut excess wire/stripped the new wires and used 2 orange wire nuts to connect each wire.
Now all the parts and pieces can be reinstalled in the reverse order
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Monica from EDMOND, OK
- Parts Used:
- W10823511
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
water leaked when the paddel was pushed
Followed the video on parts page. I was worried I would brake the cover but learned from the video the right way to remove the front plate. I found the video very informing. Thank you for saving me a service call and the part cost was minimal compared to a new refrigerator .
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- SCOTT from ELECTRIC CITY, WA
- Parts Used:
- WP67003426
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
Freezer would not defrost, refrigerator was warm, no airflow into fridge
Info on your site allowed me to determine the most likely cause of the problem, defrost thermostat, and that fixed it. Good installation instructions on the site too. Part was super easy to install. Hardest part was removing the snap-in/screwed-in plastic parts that held the sliding baskets and back panel in place. Didn't break any.....Thank You!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ronald from WESTERVILLE, OH
- Parts Used:
- W11658402
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Broken black plastic spring mechanism inside freezer rail
Remove rail and removed broken black plastic spring mechanism with new one and then replace rail.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Capac, MI
- Parts Used:
- M1205302, WP10450603
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
broken roller
proped up frig, loosened screws, cut pin, installed rooler w/ new pin, rounded pin end, reistalled, lowered frig...everyone happy, thanks again partselect.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- J. Bradley from Wellsville, NY
- Parts Used:
- D7824706Q
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Ice maker eitehr wouldn't make ice, or made odd shaped cubes
First, I shut off the water going to the refrigerator, then removed the ice bin. Then I loosened the two screws on the top of the ice maker (the one toward the front was a little tricky, since you can't see it at all), then removed the screw that fastens the lower bracket to the side of the frig. Then I lifted up on it slightly to remove it from the two upper screws, then unplugged the wiring harness from the side of the refrigerator and lifted the whole unit out of the frig.
I then removed the plastic cover on the front of the ice maker, pressed on the tab to remove the wiring harness from the old ice maker, and installed it on the new ice maker. I then removed the metal arm from the old ice maker and installed it on the new unit as well. The last part that I moved from the old ice maker to the new one was the lower bracket, as the bracket on the new ice maker was bent during shipping.
Once those parts were swapped, I put the plastic cover on the new ice maker, plugged the wiring harness back into the side of the frig, routed the fill tube into the back on the ice maker assembly, and set the unit back on the two upper screws. I then put the screw back in the lower bracket, tightened the two upper screws, and then put the ice bin back in and turned the water back on. After a couple of hours, I threw out the first couple of batches of ice and it is now working as it had in the past.
I also noticed, when looking at the old ice maker, that the black plastic coating was coming off the ice cube tray, so it was a good time to be replacing it anyway. Overall, a very easy job (I was prepared for swearing, parts being slightly off, etc.) and it would have been a shame to have paid someone to do it.
I then removed the plastic cover on the front of the ice maker, pressed on the tab to remove the wiring harness from the old ice maker, and installed it on the new ice maker. I then removed the metal arm from the old ice maker and installed it on the new unit as well. The last part that I moved from the old ice maker to the new one was the lower bracket, as the bracket on the new ice maker was bent during shipping.
Once those parts were swapped, I put the plastic cover on the new ice maker, plugged the wiring harness back into the side of the frig, routed the fill tube into the back on the ice maker assembly, and set the unit back on the two upper screws. I then put the screw back in the lower bracket, tightened the two upper screws, and then put the ice bin back in and turned the water back on. After a couple of hours, I threw out the first couple of batches of ice and it is now working as it had in the past.
I also noticed, when looking at the old ice maker, that the black plastic coating was coming off the ice cube tray, so it was a good time to be replacing it anyway. Overall, a very easy job (I was prepared for swearing, parts being slightly off, etc.) and it would have been a shame to have paid someone to do it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Severn, MD
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers, Socket set
Ice Maker was leaking
Used socket set to remove screws. Removed the wire harness, then removed lift arm from old ice maker and then put lift arm on the new ice maker. Reinstall wire harness then installed back in freeze with the screws. Video was very helpful. I will do business with Partselect in the future. Shipping was very fast. Thanks Partselect
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Keith from OLYMPIA, WA
- Parts Used:
- WPW10196393
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Noisy damper
Easy fix, it's right in the back of the fridge under a cover that just clips in, a piece of foam, and two screws. The hardest part is getting the clips free without breaking them. After replacement it's silent instead of making a grinding noise regularly.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from EVERETT, WA
- Parts Used:
- W10436252
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Frost on the edges of the freezer and all around the freezer door
I was getting small sections of ice and a snow like build - up around the freezer door. I thought that the door was not sealing tight enough and that the cold air was leaking out. The original door gasket appeared to not have any flexibility anymore and was getting hard. I ordered a new door gasket from PartsSelect. When the gasket arrived it was in a large enough box and that saved me some time as the gasket was not "crushed" to the point where there were a lot of kinks in the gasket. I used a hair dryer on low to warm the gasket and stretch it out some. The freezer door required me loosening four small screws and lifting the door off. I placed the door on an old blanket so not to scratch the finish. It was easy to remove the old gasket and after doing so I cleaned the track where the new gasket was to go with isopropyl alcohol, Once cleaned, I placed the gasket over the channel in the door where the old gasket had been and started installing the new gasket. I started at the corners and you can feel the gasket snap into place. Once the four corners were done I started at the top and installed the gasket the rest of the way. You can feel it snap into place. as you work your way around the gasket channel. Once the gasket was in place I placed the door on the four small grooves where the door had been and tightened up the screws. I made sure that no white from the inside of the freezer door was showing after the gasket was in place and that the gasket had some "spring" to it. The door was back on, the gasket was tight and it appeared to be a good seal. Around 12 hours later I checked the freezer and there was no more ice or "snow" on the edges of the freezer. While the gasket was not inexpensive, it is a genuine OEM piece, and the gasket is a lot cheaper than a new refrigerator!
I hope this was helpful...
I hope this was helpful...
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dave from Manchester Center, VT
- Parts Used:
- W11384469
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Socket set
Refrigerator light would not stay on
Removed the 2 screws holding the light bulb shield, then the 4 uolding the metal panel. Unplugged the olw door switch and replaced.
reassembled the pieces.
reassembled the pieces.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sam from Las Vegas, NV
- Parts Used:
- WP628356
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Water Fill Cup Broke
The Ice maker unit had to be removed and the shaft had to also be removed, which required dis-assembling the motor drive. The thickness of the shaft and the bearing fill cup prevents it from simply pushing it in place. Other than that I have Ice.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Wayne from PENNINGTON, NJ
- Parts Used:
- WPW10128551
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
Thought motor was bad freezer cold fridge hot
Ordered new fan motor
Got part took fridge apart
Result was the motor was running
The fan blade had come off the motor
Replaced the motor anyway and reinstalled the fan, working well
Got part took fridge apart
Result was the motor was running
The fan blade had come off the motor
Replaced the motor anyway and reinstalled the fan, working well
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sung-Su from BISMARCK, ND
- Parts Used:
- W11396033
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Broke the Rocker Switch in Fridge side
Popped out with butter knife and unplugged 3 prong connector and reversed with anew switch.
But, unfortunately it got broken again exactly same way as before.
So, I ordered same switch again for 2nd time.
Maytag should recall that Rocker Switch and build with better materials.
But, unfortunately it got broken again exactly same way as before.
So, I ordered same switch again for 2nd time.
Maytag should recall that Rocker Switch and build with better materials.