Models > CSDI25C-P73320-52W > Instructions

CSDI25C-P73320-52W Amana Refrigerator - Instructions

Jump to:

All Instructions for the CSDI25C-P73320-52W
46 - 60 of 142
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
John from Greensboro, NC
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Outer case of freezer was heating up, not making ice (sometimes) turned up thermostat several times (especially freezer)
I got the product very quickly. (thank you) Looked at online instructions that were quite vague. Pulled plug.Removed the holder for the fan motor slid it out to see what I had. Removed the mounting screws (3) and slid the motor an fan blade out. I made a cut between the wires and marked the "top" wire to motor to be sure to spin in right direction. Removing fan blade hold down clamp was NOT explained at all but I noted that the shaft on the motor was threaded, so I used pliars and held the shaft white un-screwing clamp. I cleaned the fan blades with degreaser and scraped edges of opening on holder opening. Make sure to use ALL the NEW parts included with this kit when re-installing. They send them for a reason. When slpicing and connecting wires it is a 50/50 shot if you don't mark before cutting. You can connect and try plugging fridge back for moment and make sure it is blowing OUT. Put everything back together and after turning DOWN the thermostats twice, fridge is back to usual. Ice maker is cranking out ice and outside case is cool to the touch.

Note: This can be a DIRTY job especially with 4 dogs in house. Fir and grease don't mix well
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Samuel from ALEXANDRIA, VA
Parts Used:
WPB5705307
Difficulty Level:
Difficult
Total Repair Time:
More than 2 hours
Ice from icemaker taste metallic; new ice maker directly from box
I did not do the repair yet, there is no schematic on how to route the hose; also no description of how to do the routing/connections.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Paul from Lowell, MI
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Socket set
original motor stopped
removed old and instaslled new. biggest problem was getting to one of the screws.
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ruff from SELMA, NC
Parts Used:
4318046
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers
Water not entering icemaker
Initial problem was water not entering the icemaker. Replacing the valve assembly did not solve the problem. Further investigation revealed the inflow tube to he icemaker had frozen water in it. Cleaned the ice our and water flowed a bit but not enough to fill the tray. Still investigating the problem.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from West Linn, OR
Parts Used:
4318046
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Wrench set
Water dispenser drip when not being used.
Unplug, turn off water supply, carefully remove lower back cardboard cover, unscrew old valve mount, lay towel down, disconnect the three water lines, modify provided “L” bracket by drilling a hole outboard of one of the slots to match/fit the wider original mount holes on the refrigerator’s bottom pan, screw top/short end of bracket to valve, cut back the two clear lines about 1/2” for a “fresh” end, connect all three lines, position valve and secure with original screws (access is tight, used small 1/4” wrench), turn on water/check for leaks, install back lower cardboard, plug in and verify function.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Douglas from Mesa, AZ
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Condenser fan motor froze up
Unplug fridge, unpluged fan motor from plug socket, removed bracket screws, removed fan retainer clip from shaft. removed screws holding fan to bracket
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Keith from Cherryville, NC
Parts Used:
R0131577
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Worked like a charm. Thanks
First I removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires... Put a thermometer in a glass of water & now runs at 38 degrees.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from North Easton, MA
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Wrench set
Condenser fan making noise
I removed 7 screws hold the heavy cardboard cover on the rear of the fridge. The dificult part was taking the screws that hold the 3 fan motor braces on the fan out. After that it was a matter of making the wire conections and putting it back in. I did not have enough room to laydown to do the work, If i had it would have been a lot easier to see the screws that had to be removed. All in all an easy job, and the part was a perfect fit.
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Doug from BRANDON, MS
Parts Used:
R0131577
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Fridge would warm above acceptable levels.
Talked to a bud who does this kind of work and he walked me thru the simple job. Also watched a you tube segment. Very easy job. Took off the front kick vent panel. Unscrewed the metal holder and unplugged old part, plugged new part in and put panel back on. Turned on unit and it is working like a charm. Got my fingers crossed just in case.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Daniel from SAINT ALBANS, VT
Parts Used:
WPA3223101
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Socket set
Water line feeding ice maker was not producing ice
Take out the elbow fill tube and check to see if ice build up inside tube. Clean tube of ice build up. Replace tube back in. In my case that corrected my problem.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from Plantation, FL
Parts Used:
4318046
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Socket set, Wrench (Adjustable)
Replacement Part Looked Very Different from Original
The wire plugs on the replacement part were in different orientations and the tubing connections were push-in versus the original threaded compression type. The repair kit did come with numerous additional tubes and brackets, but there were no instructions for their use. The slots on what looked like a mounting bracket adapter were not on the same centers as my original mount so I could only use one of the mounting holes - which should be OK since it is not under a lot of load after installation. I cut 3/4" off each of the outlet hoses to get a fresh, round hose end and installed the appropriate metal hose supports in the hose ends before shoving them into the push-in fittings. The size differences in the small, sheet metal internal hose supports are subtle, so be sure to double check them before installation. Be sure to press the hoses in fully or you will have a mess on your hands when you turn on the water (ask me how I know). I had to do some small re-routing of the wires to connect to the new wire connector locations (the wires were long enough). The inlet water connection was the same as original (screw on compression). I had no issues with that. After installation I actuated door water several times to make sure the press-in fittings would not work loose. I also monitored ice machine to make sure no leaks after several actuations. The differences in the original and replacement part were a little intimidating at first, but it can be made to work. 4 weeks so far and no issues, Very happy that a replacement part was available for my 21 year old fridge.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Garry from DOWNERS GROVE, IL
Parts Used:
4318046
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Wrench (Adjustable), Wrench set
Ice maker fill tube freezing solid / no ice
Watched instructional video, read all printed instructions and repair related posts
It's all there. Works great! Thank you!
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Cave Creek, AZ
Parts Used:
R0131577
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Evap Fan Stopped Blowing..
My fridge / freezer started getting very warm. But, the compressor and condenser fan were operating. I chose the defrost timer from the parts select suggested list. I took it apart and noticed the contacts were in bad shape. I validated this with my dvm meter. By checking continuity across the contacts while turning the timer knob. I also used my meter to check for 115 vac across the 2, 1 connections. . As you turn the timer knob, you'll hear a click. This should close the contacts and connections 4,3 should power up the evap fan. I also pulled the evap fan and powered it up on my test bench. I did this just to validate the timer was the problem. So, if you have a running compressor and condenser fan. Check the contacts on the defrost timer located under the front grill of your unit with a dvm. There is a small gear motor that runs the timer. Don't be fooled by the fact it's running. If the contacts are toast, replace the timer unit. Total time to fix the problem should be 15 mins. Tops.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Santos from Boca Raton, AL
Parts Used:
R0131577
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
The fridge started leaking water and stop cooling!
I used the process of elimination. The freezer was cold but the fridge side was warm. The motor was runing but the fan was not working. I unplugged the power cord and pulled everything out of the freezer. Then I took the coil cover out. The unit was frozen solid. I used my wifes hair dryer to melt the ice on the coil and spray water with a bottle to speed up the process. It took about 15 minutes to melt the ice and plug the power cord again. The motor kicked on and the fan started blowing right away so I know it's not the fan. The following morning it was frozen again. I repeated the process of taking everything out and tested the heater element with a multimeter. It wasn't working allowing the ice to build over the coil so I replaced it. It took about 30 minutes to replace but two days later it froze again. I read a little to learn about the timer and the thermostat function in a refrigerator. The timer rotates to turn off the motor and turn on the heater element to melt the ice on the coil. I tried to rotate it but it felt too hard to turn and it smelled burnt out so I replaced it at once. It took me less than 10 minutes to replace. I also learn that the thermostat reaches certain temperature and activates the fan which blows the cold air out of the coil and throughout the fridge compartments. Because the coil and the thermostat were getting covered in ice, it was not activating the fan to blow the air out keeping the freezer side cold and the fridge side warm. By replacing them both, the thermostat and the timer I solved the problem. It took about 30 minutes to replace the thermostat but now it's working like a brand new one again.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kevin from COVINGTON, LA
Parts Used:
833697
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Pliers
refrigerator stopped cooling due to condenser over-heating
Pull refrigerator out to access back, unplug unit and remove the 3 .25" screws cut the power leads to motor and install new with easy to understand instructions provided with new motor. Plug refrigerator back in and enjoy your cold beverages once more. EASIEST REPAIR EVER.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the CSDI25C-P73320-52W