CSDI25C-P73900-8W Amana Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Norma from Unionville, MO
- Parts Used:
- WPA3073101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Needed a new bulb under the microwave.
After unplugging the microwave and removing the screw, I removed the old bulb and put in the new one!! I made sure it was in securely and the difference in the light was awesome! I use this light when I bake bread and let it rise inside the microwave, but DO NOT turn it on. The heat from this light helps the bread to rise properly!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- JEFFREY from SHAWNEE, KS
- Parts Used:
- 4318046
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
The ice maker was leaking water into the freezer.
I watched the video to get up the courage to try the repair myself. I figured out the refrigerator model umber and ordered the parts on line from Parts Select. Parts showed up in a few days. Pretty easy so far. Under close scrutiny of the wife, I unplugged the refrigerator. I used a nut driver on my cordless screw gun to remove the back cover and valve. I removed the plastic water lines and electrical connectors from the old valve and attached them to the new part. Everything matched perfectly. I replaced the valve and back cover. I pluged the refrigerator back in. It might have taken 20 minutes total. The wife has her icemaker back online and I'm a hero! Thanks Parts Select!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dale from bothell, WA
- Parts Used:
- 4318046
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
no water in door, no ice.
I replaced the dual solenoid valve and made sure the ice cube tube was clear of any ice. Sure enough, it works and the nice old neighbor lady is happy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mary E. from Chicago, IL
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
Frozen Lettuce In Crisper
My husband put in in, no problem and all is well. My husband is a mechanic for large machinery/motors so installation was no problem. Thanks, better than buying a new fridge!!!
Was this instruction helpful to you?
Thank you for voting!
Refrigerator stopped running
We described the problem of the freezer and refrig not keeping cold and with the suggested parts to order and the amazing videos to follow my husband repaired it. We have one part we ordered for temperature control (RO16088) and are waiting to see if it needs to be installed. What a joy it was to hear the sound of ice cubes being made. The refrigerator went out during very hot weather. Thank you again for your wonderful help and videos. Paul and Mary Jo
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Nancy from Gallatin, TN
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
condenser fan wore out
The kit I recieved was perfect. All parts fit and where a perfect match. I will give you an A+ in handling my order and shocked by speed of your delivery.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ray from Fargo, ND
- Parts Used:
- 4318046
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Wrench (Adjustable)
Ice Maker not getting water
Replaced the intake water valve on the back side of the ref. The dual-valve water valve kit instructions were very good and the new replacement valve fixed the problem and the ice maker is working once again. The extra parts received were not needed as all the existing water lines connected without a problem to the new valve. It took a few hours for the Ref. and the ice maker to recycle and start to work properly. Pleasantly surprised that the parts were available for a 27 yr.old fridge.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Honz from Tucson, AZ
- Parts Used:
- 833697
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Socket set
intermittent loud whirring noise
Moved fridge out from wall, unplugged power cord. Laid on floor, removed 6 screws from cover. Removed one threaded bolt to allow assembly to slide out. Removed special nut, and took fan off. Removed 3 motor mounting bolts. Unscrewed 2 wire nuts, and untwisted wires. (option 1, no ground) Vacuumed entire area around motor. Used 3 bolts to mount motor to holder assembly, and special nut to install fan. Stripped wires back about 3/4 inch. Twisted two wires together CW, and installed new wire nuts. Slid motor assembly back into slot,(keep wires away from blades) and used one threaded bolt to secure assembly. Reinstalled cover plate with 6 screws. Plugged power cord in to test air flow (out through cover vents). Moved fridge back into place. The loud whirring noise did not stop for a day; then quiet!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Salem, WI
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Freezer was not getting cold enough
Mine was alittle different than the online instructions. 1. I removed the motor. 2. I took the fan off the old motor and cut the wires about 3" back from old motor. 3. Mounted the new fan on bracket and put the fan on the new motor. 4.connected wires that were cut and used wire nuts to connect. 5. Mounted bracket and motor/fan to unit and it works like its brand new. Thank you PartSelect!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- ted from old hickory, TN
- Parts Used:
- R0131577
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
freezing up & ran too long
followed repair help directions
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Myrna from Decatur, IL
- Parts Used:
- 833697
- Difficulty Level:
- Difficult
- Total Repair Time:
- 1- 2 hours
Fan motor worn out
My Son who is not an appliance repairman did it for me. He had some difficulty getting the nuts and bolts loose mainly. Sorry I'm not much help other than that! I would like to compliment you on your fast service, first time ordering from you and it was for an older model refrigerator that my repairman said he couldn't find. It's working fine now and I'm a satisfied customer!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dik from Quincy, MA
- Parts Used:
- 833697
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers
Fan was making noise, Freezer temperature was erratic
First, watched video on Part Select Website. Very good. Pulled Appliance out from wall, Pulled the power plug, and removed the back shield covering the working parts of the unit. Found the fan and it was almost the same setup as on the video except that I could not get to one of the screws holding the motor in place so had to remove the entire bracket with the fan. Not too hard. Cleaned away dust and gunk around the site and noticed that the fan pulled air through a tunnel-like condenser coil that was packed with gunky lint...this is what probably killed the motor. I cleaned out the tunnel with the bottle brushes and vacuum and installed the new motor / bracket assembly. Then replaced the shielding around the fan and the back cover .panel. This is important because these form the channel that guides air flow throughout the condenser coils. This particular refrigerator has a barrier underneath which guides air flow from the front left to the condenser, through the fan, over the evaporator drip pan and out the right front. I cleaned all the lint and gunk from this area as well. I also made an air filter (cut from a furnace filter) and wedged it in front of the air entry section. This should keep the condenser coil cleaner over time but you have to remember to change the filter once a year. Probably should clean the condenser coil every 5 years as well. This unit has been very reliable over 20 years and may well go for another 20. Good luck with your repair.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dale from Sterling, AK
- Parts Used:
- 833697
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Socket set
wouldn't make ice, door seal was hot to touch, warm in fridge.
I folded in half twice! and took the back off the fridge(cardboard) and took one brace off and just took the screws off the fan from the other two braces. Turned the fan enough to get at the wires for the fan and cut them off an inch from the old fan, stripped the insulation and wire nutted them to new fan. Make sure they don't interfere with the new fan and put the new fan in place put the screws in and we're making ice and cold fridge again.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Donald from Strafford, NH
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Socket set
Refrig ran and ran with a lot of hot air coming from the back. Temps in freezer and refrig areas would fluctuate with the unit running almost constantly. Discovered the fan was intermittently running, mostly not.
Removed the old fan; cut the wire and spliced in the new fan and reassembled. A little over one hour. Refrig is working perfectly now with lower settings. It is definitely off much more than on now.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Batavia, OH
- Parts Used:
- 833697
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Pliers, Screw drivers
blower motor was going out
just had to remove the fan motor the hard thing is getting down to it
Was this instruction helpful to you?
Thank you for voting!