- Customer:
- richard from colorado springs, CO
- Parts Used:
- D7824706Q
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers, Socket set
Ice maker stopped functioning
Part received was what I needed. There was one issue--the 'feed' opening to receive water and direct it into the ice tray was a side feed and what I needed was a back feed. That means I had to do some exchanging of parts to make it work. That exercise took more time that the actual installation.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Westfield, MA
- Parts Used:
- WP10442411
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
Abnormally warm temperatures in freezer/fresh food section
After unplugging the appliance I needed to thaw a large ice buildup off the evaporator cover panel before I could even remove the panel. The freezer being on the lower part of the appliance has the evaporator mounted vertically and it was 100% encapsulated in rock hard ice. It took over an hour to thaw the ice and collect all the water with a shop vacuum, since the condensate pan began to overflow.
One thawed, I checked all wiring for good connection, checked heater, defrost thermostat, timer unit with multimeter. The defrost thermostat checked out fine after putting it into another freezer for a 15 minute cooldown, but I noticed a crack in the seal and suspected internal moisture and decided to replace that part. A simple plug in of two leads to the new part after clipping it to the evaporator, replacement of the panel, and the appliance was up and running problem free.
A workbench disection of the old part confirmed my assessment, it had internal rust and water and had failed causing the defrost cycle failure.
One thawed, I checked all wiring for good connection, checked heater, defrost thermostat, timer unit with multimeter. The defrost thermostat checked out fine after putting it into another freezer for a 15 minute cooldown, but I noticed a crack in the seal and suspected internal moisture and decided to replace that part. A simple plug in of two leads to the new part after clipping it to the evaporator, replacement of the panel, and the appliance was up and running problem free.
A workbench disection of the old part confirmed my assessment, it had internal rust and water and had failed causing the defrost cycle failure.
Was this instruction helpful to you?
Thank you for voting!
leaky ice maker - non-stick coating had failed
replaced the entire ice make - 3 screws and a squeeze -off connector and it's out. Reverse to re-install... except that the fill tube had iced up. To thaw the fill tube: unload freezer section (leave food in fridge, but keep door closed), remove ice maker. Boil water, dip drill bit (dull end) into hot water, swirl around, insert (dull end) into to fill tube. Depending on how hot you got it, maybe a tablespoon of ice will melt. Repeat many times - fill tube is about 14" long! Do not use anything sharp - you will nick the tube and ice will form causing you to repeat this procedure. Do not try to break the ice - let the heat work. It took me about 30 minutes to thaw the whole thing - it made a nive gasping noise when the final plug opened up. Re-install ice maker.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- JOHN from WESTMINSTER, CO
- Parts Used:
- R0131577, WP10442411
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
poor cooling
removed cover in back of freezer and observed that defrost cycle seemed to happen too often. In comparing the existing part # with the factory part, I determined that possibly the wrong part was installed previously. (it had a 6 hr cooling cycle with a 45 min defrost...spec said I should be 8 hr cool & 20 min defrost) I did research on applianceguru.com... well worth the 5 bucks! I ordered a timer & thermostat & purchased a special refrigerator brush to clean the coils on the bottom. Cleaned the coils, replaced the parts in about 15 minutes and WA-LA! the freezer started getting really cold, but the fridge wouldn't get below 55. but it FELT cold! I swapped thermometers with the freezer & found out the thermometer was faulty!!! I now have the cool control backed down to 5/7 & freezer to 6/7. temps are freeze 0 and cool 40. works better than since we bought home 5 yrs ago! research & troubleshooting took a bit of time, but by the time I ordered parts I felt very comfortable I had the right parts. All said, cost me about 40 bucks instead of probably $200 from tech... schematics from partselect.com were very helpful as well!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Peter from Lancaster, PA
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
water leak and frezes ice in bin
to easy to describe, remove 3 screws and a wire plug then install new unite.
Works great
Thanks
Works great
Thanks
Was this instruction helpful to you?
Thank you for voting!
The left side crisper frame and support post (plastic pieces) were broken.
I emptied the refrigerator, pulled out the crisper drawers, removed the left side crisper frame and support post, slid in the new frame and post (no tools required), reinstalled the crisper drawers, reloaded all the food back into the refrigerator. I was done in less than 15 minutes. One of the easiest repairs I have ever had to do.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Shannon from Portland, OR
- Parts Used:
- 10897102
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Left side glide broken on the meat/deli drawer
I had to remember how the original broken part of the drawer glide was placed in relation to the other parts of the drawer. I removed the screws for the moving parts and took the broken glide off. I crossed my fingers that the new plastic glide didn't break as there were a couple of places where the glide had to snap into place. It worked perfectly.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Yafa (and David) from Bothell, WA
- Parts Used:
- 8009
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Replacing the bulb in the freezer side
Removed the ice brucket,
Removed the light shield by releasing one screw using a nutdriver.
Replacing the bulb and reinstalled the light shield.
Your web site is one of the best and most helpfull service sites I ever used. Just wish that in the future you will ship parts overseas.
Removed the light shield by releasing one screw using a nutdriver.
Replacing the bulb and reinstalled the light shield.
Your web site is one of the best and most helpfull service sites I ever used. Just wish that in the future you will ship parts overseas.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas from Roseville, CA
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Door light switch disintegrated
Very simple fix, remove 3 screws, two connectors to the old switch
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jeffery from vero beach, FL
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
water overflow,coating on tray peeling off
remove 3 screws,rotate assembly,depress lock on wire harnass connector,un plug harnass.remove old assembly,remove and transfer side cover and steel wire at front of assembly,connect harnass to new assembly,rotate into place,aling screw holes and install 3 screws.flip front steel wire down and wait for about 1 hour,first tray of ice will fall..all done.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- stu from richmond, VA
- Parts Used:
- W11384469
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Socket set
fridge door switch did not work
I removed the switch housing (4 screws), replacing the switch in the housing was a snap. It took 5 minutes, cost $8 and light works like new!
Why didn't I order this part and do the repair earlier? Very simple.
Why didn't I order this part and do the repair earlier? Very simple.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Curtis from Barrington, IL
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Old ice maker started leaking
Took under 5 minutes. Removed two screws and unplugged the wire bundle from refrigerator. Removed old unit. Put old wire bundle on new unit. Plugged wire bundle back into refrigerator and remounted the new ice maker. Could not have been easier. Watched the video first, it was very helpful.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kathleen from Long Beach, CA
- Parts Used:
- 10370035
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Broken glass shelf
I was heartbroken when I shattered the 27 inch long glass shelf while cleaning the refrigerator. It slipped out of the frame when I was sliding it back in. Part Select came to the rescue. Not only did they have the replacement glass for only $20, but it arrived practically the next day! I just slid the glass right in. No tools necessary.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Raymond from Northglenn, CO
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Not making ice, and water leaking in freezer
Unplugged the power, removed old icemaker by removing 3 screws and unplugging a small wire harness
Then i moved the wire harness off the old one to the new one, moved the end cover over to new one and plugged the harness back in and screwed it back in and turned it on
ALL FIXED!
Then i moved the wire harness off the old one to the new one, moved the end cover over to new one and plugged the harness back in and screwed it back in and turned it on
ALL FIXED!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- dorotea from staten island, NY
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Light didnt go on
The light rocker switch wasnt working. I found the part on the web site. It was so easy. I used a screw driver to pop out the old one and pop the new one in. It took 5 min. Thanks!!!
Was this instruction helpful to you?