After years of wear the toe grill to our refrigerator cracked
Pulled the old grill out of its two pressure clamps and inserted the new grill in the emptied retainers
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Yafa (and David) from Bothell, WA
- Parts Used:
- 8009
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Replacing the bulb in the freezer side
Removed the ice brucket,
Removed the light shield by releasing one screw using a nutdriver.
Replacing the bulb and reinstalled the light shield.
Your web site is one of the best and most helpfull service sites I ever used. Just wish that in the future you will ship parts overseas.
Removed the light shield by releasing one screw using a nutdriver.
Replacing the bulb and reinstalled the light shield.
Your web site is one of the best and most helpfull service sites I ever used. Just wish that in the future you will ship parts overseas.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- THOMAS from WILLARD, OH
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
defective light switch
inserted a knife between the switch and the plastic interior in order to pop the switch out.
then took off the 2 wires on the old switch put them on the new switch and reinserted the switch into the plastic interior.
then took off the 2 wires on the old switch put them on the new switch and reinserted the switch into the plastic interior.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Douglas from Simsbury, CT
- Parts Used:
- WP10442411
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers
The upper refrigerator section was warm, but not the freezer
The refrig seemed warm so I checked the temp of some liquid with a thermometer. Readings were above 60 degrees and I knew food would spoil soon. I vacuumed the dog fur off the cooling coils underneath the machine to see if that would help. Nope. I realized cold air from the freezer was not reaching the refrig. The fan was working but no cold air was coming out. I figured a blockage either in the air duct from the refrig or in the return duct to the freezer. I didn’t see any blockage in the refrig section. I took everything out of the freezer and removed the back wall. The cooling coils were completely frozen solid with frost. Being a frost free machine, I knew there were heaters that were controlled by a timer that melted this frost away periodically and that this cycle was no longer working. I found a schematic on the web, maybe your site, and educated myself on the heater circuit. The circuit consisted of a timer, thermostat near the coils, and a cal rod heater all wired in series. The timer was easy to get to and being a mechanical device I figured it must be the culprit. I ordered one online. I checked its operation and it worked fine. Realizing time was short, I hot wired the cal rod around the thermostat and rotated the timer to its heat position. The frost melted quickly and I put the freezer back together and ordered a thermostat. I canceled the timer order. When it arrived, I installed the new thermostat and it has worked fine for the past month. A little colder than usual as I don’t yet have the settings back to where they were. I have checked the operation of the old thermostat. It’s supposed to close at 30 degrees and open at 45. I have done a continuity check on it by putting it in the freezer, letting it cool down, take it out, let it warm up and it seems to work fine. So I have doubts if I really solved the problem. Wire connections were tight and not corroded. Maybe the timer was hung up on debris that I freed by cycling it. I don’t think this is the end of the story.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Westfield, MA
- Parts Used:
- WP10442411
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
Abnormally warm temperatures in freezer/fresh food section
After unplugging the appliance I needed to thaw a large ice buildup off the evaporator cover panel before I could even remove the panel. The freezer being on the lower part of the appliance has the evaporator mounted vertically and it was 100% encapsulated in rock hard ice. It took over an hour to thaw the ice and collect all the water with a shop vacuum, since the condensate pan began to overflow.
One thawed, I checked all wiring for good connection, checked heater, defrost thermostat, timer unit with multimeter. The defrost thermostat checked out fine after putting it into another freezer for a 15 minute cooldown, but I noticed a crack in the seal and suspected internal moisture and decided to replace that part. A simple plug in of two leads to the new part after clipping it to the evaporator, replacement of the panel, and the appliance was up and running problem free.
A workbench disection of the old part confirmed my assessment, it had internal rust and water and had failed causing the defrost cycle failure.
One thawed, I checked all wiring for good connection, checked heater, defrost thermostat, timer unit with multimeter. The defrost thermostat checked out fine after putting it into another freezer for a 15 minute cooldown, but I noticed a crack in the seal and suspected internal moisture and decided to replace that part. A simple plug in of two leads to the new part after clipping it to the evaporator, replacement of the panel, and the appliance was up and running problem free.
A workbench disection of the old part confirmed my assessment, it had internal rust and water and had failed causing the defrost cycle failure.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tonya from Grand Prairie, TX
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
Refrigerator quit cooling and the freezer wasn't freezing anything
Order the part from the Internet on Sunday, it mailed out on Monday and I received it on Tuesday. I unplugged the fan then undone 3 screws that held the fan bracket to the refrigerator pulled it out unscrewed 3 more nuts and replaced the fan on the bracket and I cut the old wire plug off the old fan and with 2 wire nuts put it on my new fan. Replaced the fan and bracket back on the refrigerator plugged it in and it works like a new refrigerator.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Hemet, CA
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Light switch wasn't working.. As I would close the door I would notice our frig light wasn't going off...
I simply removed the old switch by gently pulling down on the old switch with a screwdriver. When it was about half way out I just gently pulled down on the old switch and it popped out... I removed the two connectors attached to the old switch by pulling on the connectors with a pliers...I tried using my fingers but wasn't able to pull the connectors off so I used pliers. It worked perfectly.. When pulling off the old connectors, make sure you attach the new switch to the same tabs on the new switch... It was very easy to do and took under 5 mins.....The light switch works perfect....P.S. You should unplug the frig while making the connection just in case....Safety first....!!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Holden, MA
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Divider front of fridge hot to touch Condenser fan not working
removed back cover, removed fan motor and replaced with new one. connected new power wires. worked right away
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- dorotea from staten island, NY
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Light didnt go on
The light rocker switch wasnt working. I found the part on the web site. It was so easy. I used a screw driver to pop out the old one and pop the new one in. It took 5 min. Thanks!!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- stu from richmond, VA
- Parts Used:
- W11384469
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Socket set
fridge door switch did not work
I removed the switch housing (4 screws), replacing the switch in the housing was a snap. It took 5 minutes, cost $8 and light works like new!
Why didn't I order this part and do the repair earlier? Very simple.
Why didn't I order this part and do the repair earlier? Very simple.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from Farmington Hills, MI
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Bad fan motor
Pop off six mounting screws and the ground screw. Remove the fan blade and reattach. Reinstall. Save yourself big bucks.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas from Roseville, CA
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Door light switch disintegrated
Very simple fix, remove 3 screws, two connectors to the old switch
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Karl from Wellesley, MA
- Parts Used:
- 833697
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Fan was noisy - bearing had failed
It's self-explanatory. The procedure is obvious; it's just a little difficult. The only hard part is attaching the mounting brackets to the fan. If you can't tighten the mounting bolts, loosen them and reposition the brackets. You might end up mispositioning them at first, because they are hard to reach.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- anthony from HAVELOCK, NC
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
changed the light bulb still would not work so I figured it was the switch sure enough.
I took a chance and ordered a switch that is next to the top of the door. looked for how to remove it easily done in ten minutes works fine last long time.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jeff from Annandale, NJ
- Parts Used:
- WP10442411
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Frost build up in freezer
1- Remove food from freezer and store in ice chest
2- Turn off refrigerator
3- Remove freezer drawers, 2 drawers, no fastener
4- Remove freezer slide out drawer front , 2 screws
5- Remove ice cube tray holder, 2 screws
6- De-ice back panel with hair dryer / blower
7- Remove back panel in freezer, 8 screws
8- Defrost refrig coil with hair dryer / blower
9- Unplug Bimetal Thermostat, 2 wires, orang / brn
10- Remove Bimetal Thermostat from coil, 1 clip
11- Install new Bimetal Thermostat
12- Re-assemble, reverse order
2- Turn off refrigerator
3- Remove freezer drawers, 2 drawers, no fastener
4- Remove freezer slide out drawer front , 2 screws
5- Remove ice cube tray holder, 2 screws
6- De-ice back panel with hair dryer / blower
7- Remove back panel in freezer, 8 screws
8- Defrost refrig coil with hair dryer / blower
9- Unplug Bimetal Thermostat, 2 wires, orang / brn
10- Remove Bimetal Thermostat from coil, 1 clip
11- Install new Bimetal Thermostat
12- Re-assemble, reverse order