- Customer:
- Richard from North Easton, MA
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Wrench set
Condenser fan making noise
I removed 7 screws hold the heavy cardboard cover on the rear of the fridge. The dificult part was taking the screws that hold the 3 fan motor braces on the fan out. After that it was a matter of making the wire conections and putting it back in. I did not have enough room to laydown to do the work, If i had it would have been a lot easier to see the screws that had to be removed. All in all an easy job, and the part was a perfect fit.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Cathy from HOPATCONG, NJ
- Parts Used:
- W11384469
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Light rocker switch broke and refrigerator light couldn't go on.
I just popped out the old switch with a flat head screwdriver. Removed the connections and then installed new switch by reversing steps. Popped in back in and the light went on.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Daniel from ZIMMERMAN, MN
- Parts Used:
- WP61002112
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
missing shelf retainer bar end cap
put end cap on retainer bar, then align with mounting hole and snap into place. approx. time to install, about 90 seconds
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lon from OLNEY, MD
- Parts Used:
- WP61002112
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
Tabs on the end caps on the door's bottom shelf Retainer bar broke off.
I pressed the end caps onto the retaining bar. Lined up the tabs and pressed the retaining bar back in place. The first side went in very easy. The second side was a little harder due to the tension of the bar and getting the plastic tabs lined up correctly and snapping them in place. Less than 15 minutes and the shelf retaining bar was fixed.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lynette from LOS ANGELES, CA
- Parts Used:
- WP10097204
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Replaced a broken starter relay that was clicking
Our refrigerator was no longer emitting cold air and clicking every 5 minutes in what sounded like a "starter" click and then a few minutes later an ending/"shutoff" click. Nothing else would happen between the clicks and we could still hear the freezer fan running in the freezer.
Frequent clicks meant that the starter relay was broken and that the condenser was not failing to start thus failing to cool.
I found very useful videos showing this process on Youtube but here are instructions:
Unplug the refrigerator and open up the back panel on the bottom. The condenser is a black round metal sphere in the center. To the right is the condenser coil which is a flat coil. Attached on the left side of the condenser is a plastic casing with wires coming out from the bottom, that is the relay housing.
Pull the plastic casing off, it is held by a metal clamp. Underneath the plastic casing is the relay. it is attached to the condenser with a straight long pin.
Pull the relay straight out, away from the condenser. You may use a flathead for leverage but I used some elbow grease and slowly wiggled it out.
Look at the relay. For my Admiral, the relay has a little headpiece that sits on the relay and connects to the pin. Otherwise you will have pulled out the relay piece and there will be wires connecting to terminals on the relay.
Remove the wires connecting to the terminals, noting which wires connect to which terminals. Take a picture on your phone if you need to. You may want to use pliers to maintain the terminal connectors on the wires and it may take some elbow grease.
Once all the wires are disconnected from the old relay, discard the old relay. You will know if it's faulty if you shake it and it sounds like it's full of broken glass. A new relay will not make that sound.
Connect the wire connectors to the new relay in the correct terminals.
Reconnect the new relay to the condenser by pushing it back onto the pin all the way.
Replace the plastic cover with the metal clamp.
Clean the dust off the condenser coils while you have the chance.
Replace the back panel and plug in the refrigerator. You should not hear any more clicking and you should feel the air from the freezer become cooler pretty quickly.
Frequent clicks meant that the starter relay was broken and that the condenser was not failing to start thus failing to cool.
I found very useful videos showing this process on Youtube but here are instructions:
Unplug the refrigerator and open up the back panel on the bottom. The condenser is a black round metal sphere in the center. To the right is the condenser coil which is a flat coil. Attached on the left side of the condenser is a plastic casing with wires coming out from the bottom, that is the relay housing.
Pull the plastic casing off, it is held by a metal clamp. Underneath the plastic casing is the relay. it is attached to the condenser with a straight long pin.
Pull the relay straight out, away from the condenser. You may use a flathead for leverage but I used some elbow grease and slowly wiggled it out.
Look at the relay. For my Admiral, the relay has a little headpiece that sits on the relay and connects to the pin. Otherwise you will have pulled out the relay piece and there will be wires connecting to terminals on the relay.
Remove the wires connecting to the terminals, noting which wires connect to which terminals. Take a picture on your phone if you need to. You may want to use pliers to maintain the terminal connectors on the wires and it may take some elbow grease.
Once all the wires are disconnected from the old relay, discard the old relay. You will know if it's faulty if you shake it and it sounds like it's full of broken glass. A new relay will not make that sound.
Connect the wire connectors to the new relay in the correct terminals.
Reconnect the new relay to the condenser by pushing it back onto the pin all the way.
Replace the plastic cover with the metal clamp.
Clean the dust off the condenser coils while you have the chance.
Replace the back panel and plug in the refrigerator. You should not hear any more clicking and you should feel the air from the freezer become cooler pretty quickly.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Douglas from Mesa, AZ
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Condenser fan motor froze up
Unplug fridge, unpluged fan motor from plug socket, removed bracket screws, removed fan retainer clip from shaft. removed screws holding fan to bracket
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Carolee from Spokane Valley, WA
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Light switch broke
Pried out old part with screwdriver. Unplugged. When new part came, just plugged it in and pushed the part into place.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- WILLIAM from TAMPA, FL
- Parts Used:
- WP61002112
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Retainer clip was broken and as a result the retaining bar could not do its job
I just snapped the new clip in place.
I would like to thank you for your fast service. The part arrived the day after I placed the order. This is almost unheard of.
Thank You
I would like to thank you for your fast service. The part arrived the day after I placed the order. This is almost unheard of.
Thank You
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Paul from Lowell, MI
- Parts Used:
- 833697
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Socket set
original motor stopped
removed old and instaslled new. biggest problem was getting to one of the screws.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from Belhaven, NC
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
cooling fan quit
Ordered new fan motor on line took out old motor and replaced with new one
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Al from Tonka Bay, MN
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
Condenser Fan Failure
Partition between Freezer and Fridge was running very hot. (Warm is normal). Oiling fan did not work. The only problems encountered in the replacement were getting fan out and in through coolant lines, cut plug off to accomodate generic fan wiring, getting the screws back in without cooking your hand on a hot compressor. Unit works great!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Anna from Long Island City, NY
- Parts Used:
- WP61002112
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
The clips on the part had broken off. As a result the bar was not held in place.
Removed the old cap from the metal bar. Slipped the new cap on the bar. Fit the bar back into the slots in the frig door.
It was perfect. The part arrived on time. The fix was quick. And simple.
It was perfect. The part arrived on time. The fix was quick. And simple.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from GROVESPRING, MO
- Parts Used:
- W11384469
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
light did not work on the refrigerator side
bulbs were not burnt out. received the new switch in a few days. watch the short video, was good to see how it comes out. used a putty knife to release the defective switch, removed wires put them on the new one and posed the new switch back in. Not bad Part cost $11.00 7 dollars shipping so for 17 bucks it works great. nice to see what is inside the refer!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Althea from Vancouver, WA
- Parts Used:
- WP61002112
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
The end caps broke on several of the retainer bars. The retainer bars kept falling out and so did my food.
I replaced the broken end caps by inserting the new ones into the ends of the retaining bar and then inserted the entire piece into the slots of the refrigerator where the bars were missing because the end caps weren't holding the retaining bar and I had to place them in a safe place outside of the refrigerator. Too easy. I'm just glad it was such an easy fix. I'm thankful for this site, the value was great, service quick and my life is now a little easier.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kevin from COVINGTON, LA
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Pliers
refrigerator stopped cooling due to condenser over-heating
Pull refrigerator out to access back, unplug unit and remove the 3 .25" screws cut the power leads to motor and install new with easy to understand instructions provided with new motor. Plug refrigerator back in and enjoy your cold beverages once more. EASIEST REPAIR EVER.
Was this instruction helpful to you?
Thank you for voting!