59671862100 Amana Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- brandon from Cedar Rapids, IA
- Parts Used:
- WP67004028, WP628356
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
shut off arm was broke and so was bracket
i just took the prts apart and replaced with new part really easy and saved $185.00 easy as pie
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- anthony from HAVELOCK, NC
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
changed the light bulb still would not work so I figured it was the switch sure enough.
I took a chance and ordered a switch that is next to the top of the door. looked for how to remove it easily done in ten minutes works fine last long time.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ross from Sun Lakes, AZ
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Ice cubes in bin frozen into big lumps due to water leaking into bin from icemaker. Lining of icemaker cube tray worn and damaged allowing leak.
Pull refrigerator out from wall to shut off water and power. Remove ice bin, pulling front down then out. Remove screw at bottom of icemaker, then pull down to release two clips, Pull out a couple inches to get hand behind icemaker to release wiring harness connector. (squeeze top and bottom to release clips). Remove unit. Remove wiring harness and wire bail from old unit and install on new unit. Reverse steps to install new unit. Make sure ice bin is fully inserted, or unit will not function.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- JOHN from WESTMINSTER, CO
- Parts Used:
- R0131577, WP10442411
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
poor cooling
removed cover in back of freezer and observed that defrost cycle seemed to happen too often. In comparing the existing part # with the factory part, I determined that possibly the wrong part was installed previously. (it had a 6 hr cooling cycle with a 45 min defrost...spec said I should be 8 hr cool & 20 min defrost) I did research on applianceguru.com... well worth the 5 bucks! I ordered a timer & thermostat & purchased a special refrigerator brush to clean the coils on the bottom. Cleaned the coils, replaced the parts in about 15 minutes and WA-LA! the freezer started getting really cold, but the fridge wouldn't get below 55. but it FELT cold! I swapped thermometers with the freezer & found out the thermometer was faulty!!! I now have the cool control backed down to 5/7 & freezer to 6/7. temps are freeze 0 and cool 40. works better than since we bought home 5 yrs ago! research & troubleshooting took a bit of time, but by the time I ordered parts I felt very comfortable I had the right parts. All said, cost me about 40 bucks instead of probably $200 from tech... schematics from partselect.com were very helpful as well!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tonya from Grand Prairie, TX
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
Refrigerator quit cooling and the freezer wasn't freezing anything
Order the part from the Internet on Sunday, it mailed out on Monday and I received it on Tuesday. I unplugged the fan then undone 3 screws that held the fan bracket to the refrigerator pulled it out unscrewed 3 more nuts and replaced the fan on the bracket and I cut the old wire plug off the old fan and with 2 wire nuts put it on my new fan. Replaced the fan and bracket back on the refrigerator plugged it in and it works like a new refrigerator.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- IRMA from SAN DIMAS, CA
- Parts Used:
- WP67005140
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
broken freezer door handle
unscrewed old handle and screwed in new one, whalaa. thank you.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Norma from Wells, MN
- Parts Used:
- WP67005141
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
freezer door handle was cracked.
replaced the handle with a new one. Very simple. Very easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- THOMAS from WILLARD, OH
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
defective light switch
inserted a knife between the switch and the plastic interior in order to pop the switch out.
then took off the 2 wires on the old switch put them on the new switch and reinserted the switch into the plastic interior.
then took off the 2 wires on the old switch put them on the new switch and reinserted the switch into the plastic interior.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Barbara H. from South Hill, VA
- Parts Used:
- WP65889-4
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers
The refrigerator stopped running
I was told to order the run capacitor and the technician thought it would repair the refrigerator; but it did not. The appliance technician had to take the run capacitor off and install what he called a "hard start" and the refrigerator is operating right now.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Douglas from Simsbury, CT
- Parts Used:
- WP10442411
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers
The upper refrigerator section was warm, but not the freezer
The refrig seemed warm so I checked the temp of some liquid with a thermometer. Readings were above 60 degrees and I knew food would spoil soon. I vacuumed the dog fur off the cooling coils underneath the machine to see if that would help. Nope. I realized cold air from the freezer was not reaching the refrig. The fan was working but no cold air was coming out. I figured a blockage either in the air duct from the refrig or in the return duct to the freezer. I didn’t see any blockage in the refrig section. I took everything out of the freezer and removed the back wall. The cooling coils were completely frozen solid with frost. Being a frost free machine, I knew there were heaters that were controlled by a timer that melted this frost away periodically and that this cycle was no longer working. I found a schematic on the web, maybe your site, and educated myself on the heater circuit. The circuit consisted of a timer, thermostat near the coils, and a cal rod heater all wired in series. The timer was easy to get to and being a mechanical device I figured it must be the culprit. I ordered one online. I checked its operation and it worked fine. Realizing time was short, I hot wired the cal rod around the thermostat and rotated the timer to its heat position. The frost melted quickly and I put the freezer back together and ordered a thermostat. I canceled the timer order. When it arrived, I installed the new thermostat and it has worked fine for the past month. A little colder than usual as I don’t yet have the settings back to where they were. I have checked the operation of the old thermostat. It’s supposed to close at 30 degrees and open at 45. I have done a continuity check on it by putting it in the freezer, letting it cool down, take it out, let it warm up and it seems to work fine. So I have doubts if I really solved the problem. Wire connections were tight and not corroded. Maybe the timer was hung up on debris that I freed by cycling it. I don’t think this is the end of the story.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- richard from colorado springs, CO
- Parts Used:
- D7824706Q
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers, Socket set
Ice maker stopped functioning
Part received was what I needed. There was one issue--the 'feed' opening to receive water and direct it into the ice tray was a side feed and what I needed was a back feed. That means I had to do some exchanging of parts to make it work. That exercise took more time that the actual installation.
Was this instruction helpful to you?
Thank you for voting!
leaky ice maker - non-stick coating had failed
replaced the entire ice make - 3 screws and a squeeze -off connector and it's out. Reverse to re-install... except that the fill tube had iced up. To thaw the fill tube: unload freezer section (leave food in fridge, but keep door closed), remove ice maker. Boil water, dip drill bit (dull end) into hot water, swirl around, insert (dull end) into to fill tube. Depending on how hot you got it, maybe a tablespoon of ice will melt. Repeat many times - fill tube is about 14" long! Do not use anything sharp - you will nick the tube and ice will form causing you to repeat this procedure. Do not try to break the ice - let the heat work. It took me about 30 minutes to thaw the whole thing - it made a nive gasping noise when the final plug opened up. Re-install ice maker.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Westfield, MA
- Parts Used:
- WP10442411
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
Abnormally warm temperatures in freezer/fresh food section
After unplugging the appliance I needed to thaw a large ice buildup off the evaporator cover panel before I could even remove the panel. The freezer being on the lower part of the appliance has the evaporator mounted vertically and it was 100% encapsulated in rock hard ice. It took over an hour to thaw the ice and collect all the water with a shop vacuum, since the condensate pan began to overflow.
One thawed, I checked all wiring for good connection, checked heater, defrost thermostat, timer unit with multimeter. The defrost thermostat checked out fine after putting it into another freezer for a 15 minute cooldown, but I noticed a crack in the seal and suspected internal moisture and decided to replace that part. A simple plug in of two leads to the new part after clipping it to the evaporator, replacement of the panel, and the appliance was up and running problem free.
A workbench disection of the old part confirmed my assessment, it had internal rust and water and had failed causing the defrost cycle failure.
One thawed, I checked all wiring for good connection, checked heater, defrost thermostat, timer unit with multimeter. The defrost thermostat checked out fine after putting it into another freezer for a 15 minute cooldown, but I noticed a crack in the seal and suspected internal moisture and decided to replace that part. A simple plug in of two leads to the new part after clipping it to the evaporator, replacement of the panel, and the appliance was up and running problem free.
A workbench disection of the old part confirmed my assessment, it had internal rust and water and had failed causing the defrost cycle failure.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Peter from Lancaster, PA
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
water leak and frezes ice in bin
to easy to describe, remove 3 screws and a wire plug then install new unite.
Works great
Thanks
Works great
Thanks
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas from Roseville, CA
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Door light switch disintegrated
Very simple fix, remove 3 screws, two connectors to the old switch
Was this instruction helpful to you?
Thank you for voting!