Models > AS2324GEKB > Instructions

AS2324GEKB Amana Refrigerator - Instructions

Jump to:

All Instructions for the AS2324GEKB
76 - 90 of 686
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Robert from Severn, MD
Parts Used:
D7824706Q
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers, Socket set
Ice Maker was leaking
Used socket set to remove screws. Removed the wire harness, then removed lift arm from old ice maker and then put lift arm on the new ice maker. Reinstall wire harness then installed back in freeze with the screws. Video was very helpful. I will do business with Partselect in the future. Shipping was very fast. Thanks Partselect
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Edward from Florance, MT
Parts Used:
WPD7749401
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Auger in the ice tray not turning
Removed ice container, replaced end cap that holds Auger shaft that connects to shaft that turns the Auger. End cap plastic nubs wear where it makes contact to the turning stub. Removing a few screws on the front of ice container allows the Auger shaft to slide forward and away from the end cap. Maneuver end cap from shaft, replace using same maneuver and that is it.
Pretty easy, even for a novice like me. A $6.00 end cap verses the whole assembly at around $70.00
I'm pleased.......
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sam from Las Vegas, NV
Parts Used:
WP628356
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Water Fill Cup Broke
The Ice maker unit had to be removed and the shaft had to also be removed, which required dis-assembling the motor drive. The thickness of the shaft and the bearing fill cup prevents it from simply pushing it in place. Other than that I have Ice.
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
SHARON from CEDAR RAPIDS, IA
Parts Used:
WP67005716, R0181181
Difficulty Level:
Very Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Socket set
Uneven doors, freezer door had to be pushed to be sure it was shut
Followed video and used vaseline to lube as suggested by other review.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Timothy from BELTSVILLE, MD
Parts Used:
WPW10503278
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Freezer box frosting up. Refrigerator not cold.
My son (who does HVAC, but not appliance repair) did some investigating by taking front and back panels off and determined that the evaporator coil was freezing over because the defrost wire was not heating up. He and his girlfriend did some real-time internet searching for diagnostic info because NO control diagram was included with the refrigerator. He determined the problem was most likely the electronic control board. Ordered and installed a new board and the refrigerator is back to working fine. Took about 2 hours to diagnose the problem and 1/4 hour to actually install the control board. Kind of disappointing that this control board failed when the refrigerator was less that 4 years old.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Denver, NC
Parts Used:
D7824706Q
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Water overflowing ice maker
Removed the 3 screws that hold the ice maker in place and remove the cover and level wire. Put the cover and wire on new part and install the 3 screws. Had ice within 1 hour. A very easy job for the do it yourselfer. Suspect the heat coil that melts the cubes was not working in the old unit and cubes stayed in the tray.
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Terry from WARMINSTER, PA
Parts Used:
W11396033
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Broken light switch
Watched video. Unplugged refrigerator and popped out switch. In plugged connector and pushed switch in place. Plugged in refrigerator and the light worked
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Orlando from Bayonne, NJ
Parts Used:
WP2300868
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Old one leaks on one side
Simply cut the water tube on both sides of connector and push in the new one.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
JEFF from SEATTLE, WA
Parts Used:
12002355
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
FREEZER WOULD NOT DEFROST.
I initially tested the heating element and defrost thermostat using an ohm meter. the defrost thermostat was incased in ice, so I replaced it first. The refridgerator worked for about a week and then froze up again. I then replaced the thermistor and the unit is working as designed.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from WASHINGTON, DC
Parts Used:
W11291138
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Light switch that causes light to turn on when door is open was nroken.
Truth is, this took a couple hours of cursing, but that was due to poor information and no prior experience. I imagine the next one would take 20 minutes. The issues are these: videos tell you to use a putty knife to pry the old switch out. That is harder than it seems because each switch has a plastic spring that pops open to hold the switch on, and you can't access the spring when the switch is installed. So it is important to use the knife on the side of the switch (left or right of spring -- look at the new switch), and back and forth until the switch is worked out. Then it can get worse. The new switch has to plug in electrically before it can be installed mechanically. In my case, with the switch on the fridge wall rather than the top, the outlet for the plug was encased in foam insullation. That gives the appearance that the plug was fixed, immovable, which makes it impossible to plug it in electrically before the switch is in place, and of course once it is in place you can't then plug it in. The problem here was poor instructions. Just scrape out a lot of the foam around the plug and you find that the plug is really not fixed, but attached to reasonably long wires that allow you to plug it in with the switch a couple inches from the wall, and then insert the switch. None of the online instructions tell you this about the wires.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from Valencia, PA
Parts Used:
D7824706Q
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver
Ice maker just stopped making ice
This was the third icemaker replaced since January 1999. Improvement need to be made in the design of the icemaker so that more than 2-3 years of life is available.
The most difficult part was disconnecting the power plug in the back of the icemaker. You must squeeze the upper and lower tabs together and pull out at the same time to disconnect. Once this is done, take out one nut head screw, lift up on the icemaker and remove from the hanger. Be careful that you don't break the plastic tabs on the hangers. Replace new icemaker in reverse, feed water supply where it must go in the back, resnap onto hangers, replace the nut head screw and snap in the power plug. It took about 2 hours before the icemaker began making ice. It has been working fine ever since. PS. I saved about $200.00 over having a repairman come in and replace the unit.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Linda from Johnson City, NY
Parts Used:
D7824706Q
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
leaking ice maker,big chunks ot ice were forming and had to remove them 2-3 times a day
removed old ice maker by taking out a couple of screws in the back of freezer,when new ice maker arrived i saw that it didn't have the same hose apparatus as old one so I easily took apart old one then took apart new one and switched them out-very-- easily done for a 61 yr old lady I might add-- also had to reinstall ice maker arm off old ice maker as new one does not come with one Then installed new ice maker in freezer I am very very pleased,sure saved a lot of money doing it my self
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sung-Su from BISMARCK, ND
Parts Used:
W11396033
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Broke the Rocker Switch in Fridge side
Popped out with butter knife and unplugged 3 prong connector and reversed with anew switch.

But, unfortunately it got broken again exactly same way as before.
So, I ordered same switch again for 2nd time.

Maytag should recall that Rocker Switch and build with better materials.
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Daniel from DAVISBURG, MI
Parts Used:
D7824706Q
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Ice maker stopped making ice
Remove 1 screw under ice maker. Gently pull downwards to unhook ice maker. Disconnected 4 pin wire connector. Remove and set aside the cover and wire loop you will need on new ice maker. Reverse the steps to install new maker. Once new ice maker is installed you will have to wait 2-4 hours for ice. There is a thermostat that will need to reach 10 degrees F to operate.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
George from Tunnel Hill, GA
Parts Used:
WP12562701
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Ice forming around ice chute
I had to order three times before I got the right part. This was due to my rush to fix the problem and not studing the diagram carefully (black and white diagrams are not that clear). The repair was very simple. Just remove the rubber from the plastic door and slip on the new one.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the AS2324GEKB