ESRF14B (P6030382W) Amana Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Janet from Ada, MI
- Parts Used:
- 8009
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
light bulb went out in my oven
My husband took the plastic cover off and took out old bulb and screwed in the new one. Then put the cover back on.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Shirley from Las Vegas, NV
- Parts Used:
- 8009
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Light burned out in upper oven
Screwed in light bulb and glass protector
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- peggy ann from forest city, NC
- Parts Used:
- 8009
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
replaced oven lightbulb
very easy
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Christopher from Carpinteria, CA
- Parts Used:
- R0131577
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
My Refrigerator got warm, stopped making ice and I could see the coils were frozen over
This is the easiest repair to perform, figuring out what was wrong took a little longer. I have the bottom freezer Amana refrigerator and the defrost timer is just behind the bottom front grill, removing four screws and plugging in the new timer took maybe 15 minutes. To find out what was not working correctly I removed the panel covering the coils in the freezer and it was totally frozen up, this is why it stopped making ice and wasn't keeping things cold. I defrosted the coils and checked the resistance of the heater to make sure it was working, it was fine so it was the defrost timer.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bruce from Fort Wayne, IN
- Parts Used:
- WP67001255
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Ice bin had been lost
1. Removed part from packaging. 2. Cleaned part with foodsafe cleaners. 3. Rinsed thoroughly. 4. Dried thoroughly to prevent frost. 5. Placed bin in freezer. 6. Turned on ice maker. 7. Waited. 8. Discarded first batch to clear supply line. 9. Waited. 10. Enjoyed ice. 11. Provided these inductions.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- William from Schwenksville, PA
- Parts Used:
- 8009
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
oven light burnt out
1. Unscrewed glass cover on bulb
2. Removed old bulb
3. Screwed in new bulb
4. Replaced glass cover
5. Mixed drink & baked cupcakes
2. Removed old bulb
3. Screwed in new bulb
4. Replaced glass cover
5. Mixed drink & baked cupcakes
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Judith from Phoenix, AZ
- Parts Used:
- 8009
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Bulb Replacement
I pulled down the wire around the glass cover. . . Released on end of the wire from its holder being careful to not let the glass cover drop. Unscrewed the bulb and replaced with replacement. Easy, easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lee from Sherman, ME
- Parts Used:
- R0131577
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Freezer was 40 degrees
Past experiences told me it was the defrost timer. Turned the timer wheel, the compressor came on and that told me the timer wasn't working correctly. I ordered the timer and put it in.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from Port Lavaca, TX
- Parts Used:
- R0131577
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
elderly neighbor"s refridgerator would not defrost
I ordered the defrost timer and then read a couple of repair history stories. The timer was fairly easy to install. Then I advanced the small knob until I felt a "click". The covers were reinstalled inside the freezer. And the appliance is normal. Plug and Play. I learned that the timer is for the activation of a heater in or under the freezer"s aluminum fin assembly. Alot of folks don"t know that a refrigerator gets it"s supply of cold air from the freezing compartment. Everybody is happy. Thanks
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- thomas from north huntingdon, PA
- Parts Used:
- R0131577
- Difficulty Level:
- Very Difficult
- Total Repair Time:
- More than 2 hours
- Tools:
- Nutdriver
ice melts
still does
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- BOB from LAKE HAVASU CITY, AZ
- Parts Used:
- 4318047
- Difficulty Level:
- Difficult
- Total Repair Time:
- More than 2 hours
- Tools:
- Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
Soleniod Valve Failed
The refrig. Is about 30 years old. The new solenoid looked and mounted nothing like the original. I driled holes in the frig and attach the solenoid with sheet metel screws. There were not enough fittings and hoses so I bought a braded metal hose to attach the ro line and the valve inlet. I used the parts in the kit to attach the water feed line. To the ice maker I did not try to stuff all the hoses and lines back into the cramped cavity in the frig. W ell how does it look? The solenoid sticks out a little and there are a lot of hoses behind the frig. I do not spend much time behind the frig so who cares. The ice maker is making ice!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Metuchen, NJ
- Parts Used:
- 4318047
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers
New Part Was Different From Previous Part
First attempt was difficult. Part was different and instructions applied to previous part that did not have quick connect. Not clear where quick connect was to be used. Result no ice!second attempt used quick connect in reverse connections and now have plenty of ice. Combination of change in part appearence from previous one ,and different from instructions included with new part, resulted in confusion in installation. In the long run, it worked out well.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lawrence from Pottstown, PA
- Parts Used:
- 4318047
- Difficulty Level:
- Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
part not like old part
The part could not be installed without home made angles which were attached to unit so that it would only protrude from back of refrigerator about 2" instead of 6".
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Julio from Sun Prairie, WI
- Parts Used:
- R0131577
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
The refrigerator was working intermittently. The ice cubes in the ice container start to melt and there was no cool air coming to the fridge side.
I removed the back cover on the freezer cabinet and discover that the evaporator coil was cover with froze and ice. I then though that one of the three component of the automatic defrost system: timer, thermostat or heater coil has stopped working. I measure the resistance off the heater coil and obtained a 54 ohms reading so that was good. I did not did a very good job with troubleshooting the timer and thermostat since I conclude that the timer was bad. I ordered and changed the timer but turned out that the faulty component was the thermostat which I replaced and the refrigerator started to work like a charm :)! The harness was not exactly the same so, I has to cut and strip two wires and reconnect; beside that everything was fairly easy to do. Thank you!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- JOHN from TWINSBURG, OH
- Parts Used:
- 4318047
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers, Wrench (Adjustable)
Water Was Not Reaching The I Ce Maker
Disconnect ac power line, disconnect power line going to the water valve. Turn water off atthe cockvalve. Disconnect water line to valve. Disconnect plastic tubing going in the valve. If plastic is old you may have to replace it to keep from leaking at the quick connect coupling. Connect water line and plastic tubling to new valve, connect power clips to new valve. Plug in the refrigertor and turn on water at the cock valve and your good to go
Was this instruction helpful to you?
Thank you for voting!