ASB2623HRW Amana Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Robert from Lake Mary, FL
- Parts Used:
- WP67004188
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
fridge to warm, icing up every three days
Wrong part, found the problem. Start with the thermostat, controls both when to start and stop the defrost cycle. Not the defrost heater or the timer.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- ronald from San Diego, CA
- Parts Used:
- W10613606
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Refrigerator compressor not run
Replaced the relay and capacitor it runs.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lanny from LYNN HAVEN, FL
- Parts Used:
- WP67004757
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Socket set
Amana Side by Side - refrigerator side began to not cool, freezer side froze up
Problem led to 3 possible problem parts, defrost thermostat, defrost heater or defrost control board. Defrost heater ohmed out to 31 ohms, so seemed good. Defrost thermostat was open when warm but was open after running refrigerator to get freezer side cold enough for thermostat to close, it did not I thought. So I ordered thermostat. Once part came in, I cut up a couple inches on orange and brown wires, stripped off enough to work with. I soldered new one in and heat shrunk the wires. I turned on and it seem to work and all night. Working fine right now.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- paula from julian, CA
- Parts Used:
- R0181181
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
door would not self close tightly
Remove two screws from top door hinge.
Remove door from unit
Remove old broken plastic cam 1 screw
Replace new door cam tighten 1 screw
Reinstall door and top hinge screws.
Remove door from unit
Remove old broken plastic cam 1 screw
Replace new door cam tighten 1 screw
Reinstall door and top hinge screws.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Eastland, TX
- Parts Used:
- WP67001036
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Frost inside freezer and not cooling refgr.
I replaced the timer defroster 2/13 and until today,2/18 the refgr was cooling properly. now there is frost in the freezer and the refgr is not cooling. I will defrost it manually. If anyone has had this problem I would appreciate your help. My email is [email protected]. Thank you.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from VESTAL, NY
- Parts Used:
- W11176463
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers
Old fill tube was blocked
Cut old fill tube into pieces, removed and replaced with new tube. Extremely easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- riley from CAVE CREEK, AZ
- Parts Used:
- WP65889-4
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Socket set
Refrig began to trip the GFI circuit in the garage. When plugged into a house interior circuit the lights and fan ran but no cooling in either the freezer or frig.
First of all I want to thank Michael from Carlisle,PA and this site for publishing Michael's info on the wiring specifics on the new 3 connector Start Relay ( WP2262185 ). The original relay only has 2 connectors The 2 orange wires which are combined to one female connector need to be clipped and separated each to its own connector. Refer to Michael's blog as to which wire goes to which connector on the Start Relay. I replaced the Run Capacitor, Start Relay and Overload just to be safe. The Start Relay was the actual culprit.Thank you for an excellent website!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- frank from NORTHRIDGE, CA
- Parts Used:
- WPD7813010
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Ice maker not producing ice
The parts were very easy to replace, however I am still without ice and cannot figure out why. I have ohm tested the contol unit and everything works fine, I am able to jump it and turn on the motor and water fill valve. Any suggestions?...
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sung-Su from BISMARCK, ND
- Parts Used:
- W11396033
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Broke the Rocker Switch in Fridge side
Popped out with butter knife and unplugged 3 prong connector and reversed with anew switch.
But, unfortunately it got broken again exactly same way as before.
So, I ordered same switch again for 2nd time.
Maytag should recall that Rocker Switch and build with better materials.
But, unfortunately it got broken again exactly same way as before.
So, I ordered same switch again for 2nd time.
Maytag should recall that Rocker Switch and build with better materials.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Daniel from DAVISBURG, MI
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Ice maker stopped making ice
Remove 1 screw under ice maker. Gently pull downwards to unhook ice maker. Disconnected 4 pin wire connector. Remove and set aside the cover and wire loop you will need on new ice maker. Reverse the steps to install new maker. Once new ice maker is installed you will have to wait 2-4 hours for ice. There is a thermostat that will need to reach 10 degrees F to operate.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mason from Tallahassee, FL
- Parts Used:
- R0181181
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Cam snapped in half on bottom of door
Super easy - emptied door of all food, unscrewed bracket from top of door, lifted door off and set aside. Broken cam removed, new one screwed in, and lubed with some Vaseline. Set door back in new cam, screwed bracket into the top, and good to go. I was kinda worried about shopping from PartSelect since I had never heard about them, but the part was here in less than 2 days. Pretty awesome little company.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dennis from Kerrville, TX
- Parts Used:
- R0181181
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
The door made a loud noise on opening and closing.
Emptied the door.
Removed the door, top bolts first.
Lifted out the door.
Installed new cam at the bottom.
Set the door back in place.
Bolted the top hinge back on.
Smooth!
The part came quickly and was the right one. You can't imagine how many outfits lose it here. Well done and thanks.
Removed the door, top bolts first.
Lifted out the door.
Installed new cam at the bottom.
Set the door back in place.
Bolted the top hinge back on.
Smooth!
The part came quickly and was the right one. You can't imagine how many outfits lose it here. Well done and thanks.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Barbara H. from South Hill, VA
- Parts Used:
- WP65889-4
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers
The refrigerator stopped running
I was told to order the run capacitor and the technician thought it would repair the refrigerator; but it did not. The appliance technician had to take the run capacitor off and install what he called a "hard start" and the refrigerator is operating right now.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- richard from colorado springs, CO
- Parts Used:
- D7824706Q
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers, Socket set
Ice maker stopped functioning
Part received was what I needed. There was one issue--the 'feed' opening to receive water and direct it into the ice tray was a side feed and what I needed was a back feed. That means I had to do some exchanging of parts to make it work. That exercise took more time that the actual installation.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Raymond from Panama City Beach, FL
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Ice maker stopped working
After checking the water valves ordered new ice maker. received the part three days after ordering! Clearing out food, removing the old one and installing the new unit took under 15 minutes. Everything went fine.
Was this instruction helpful to you?
Thank you for voting!