Customer:
Rodolfo from South San Francisco, CA
Parts Used:
W10613606, WP65889-4
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Refrigerator stopped cooling
Problem: My Maytag side by side door refrigerator just stopped cooling and has to discard all frozen items after I discovered being away for 3 days. First, I went to my computer and read some of the repair stories at Part Select “Need help with your repair?” and installation video guide.
1. I ordered the Refrigerator Adaptive Defrost Board (ADP) - followed the procedures how to disconnect and installed the new part. Unfortunately, it did not correct the problem and only warm is coming out.
2. I ordered the Defrost Heater Thermostat Assembly - removed the old and replaced with new assembly. Again, warm air coming out. Meanwhile, I kept on hearing “clicking sound every few second” not knowing where this coming from. Again, at Part Select, I read the story about it and I ordered the
Run Capacitor and the Overload/Relay with Capacitor. Soon as I opened the parts and tried to match it from the part at the back of the refrigerator and to the part from the compressor, I have discovered that they are not in compatible with the original parts from my Maytag Refrigerator and cannot be installed. And so I contacted (Email) Part Select customer service (Jeanette) if I could return the unused parts and had provided me the “Return address and the Reference Number”. This time, I gave Jeanette the Maytag Model and Serial numbers and asked where I could find this on my refrigerator and make the necessary repair and came back with the diagram and located #4 to the compressor. Ordered the correct part# PS2004058.
3. Upon receipt of the part above, I was puzzled, in the plastic container are four parts, included a plastic cover. I have not given up, I removed the original part encased in white plastic container pulled straight off the compressor and examined it closely. Before detaching all the wiring, I also noted before disconnecting from wire harness and read the Diagram/Instruction Sheet provided.
4. From the four new parts provided, installed the Overload Terminal, bottom part on Compressor with one terminal to the Blue wire. Connected White Jumper to the old harness. Lastly, I plugged the PTC Start Device (two terminals) above the Overload Terminal on the Compressor with the proper wiring as I previously noted and installed the electrical cover. “Plugged in the refrigerator to the power outlet”. To test the result, I left a glass of water inside the freezer and a bottle of wine into the refrigerator. The result - I checked after 2 hours, the water was frozen and a cool wine. “Little frustration included here, as I am not an electrician.” But now, I could say, I fixed it, and very proud of this accomplishment.
Thank You, PartSelect and to a great Customer Support!
Safety Note: Always make sure to unplugged the refrigerator (power off) prior doing the necessary repairs.
Rodolfo Julao/S. San Francisco, CA
39 of 45 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
robert from nashotah, WI
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Socket set
noisy fan motor
rmv panel (5min) rmv fan/motor 3 screws (10 m) cut wire 2in from motor, re route remainder of wire to front so can strip for wire nuts. ( 10m) attach old fan to new motor, place in old opening ,3 screws, a little fussy to align, ( 15m ) route and strip wire from new motor , zip ties work well, wire nuts , plug in fridge vola, no noise, close up, reverse panel. ( 20m). i also took time to clean grilles with small vac and damp rag, ( looks and sounds like new) bob Wi.
37 of 45 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Fred from Oceanport, NJ
Parts Used:
W11291138
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
Door switch module wore out
Pull out old module...
Remove 2 wires...
Tape to inside wall [don't want them to fall down into side panel]..

Order new switch..

Fed Ex pkg came on 2nd day..

Install wires on switch...
Press into opening...
Check door light on..[OK]
.. Done
40 of 55 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
ANTOINETTE from BALTIMORE, MD
Parts Used:
WP67004757, WP67004188
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Freezer gets ice on coils and Refrigerator gets warm!!
I defrosted the ice from the freezer coils with a blow dryer and then removed the back panel from the freezer and I change the defrost heater and the defrost thermostat, I believe that being I am a woman and not really knowing what I was doing, (only what I read on PartSelect) that it took me as long as it did...Once I realize what I had to do, it was over in a jiffy....So far the Refrig and Freezer seem to be working fine..
30 of 34 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Leo from Salem, SC
Parts Used:
WP2300868
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Had to replace a hose connector at the base of my refrig/frreezer
Perhaps a helpful hint:

When aI received the hose adapter/connector, I inserted the 2 hose ends only to have water drip from the connection.
I used a utility knife to remove an inch from each side, then reinserted the hoses. That made the differnce. Dry as a bone.

LG
43 of 76 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
william from avon, OH
Parts Used:
R0181181
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Socket set
Door cam worn out
remove top plastic cover / phillips screw driver
remove top door bracket / 5/15" socket
lift off door
remove pieces of old cam / phillips screw driver
replace cam/ phillips screw driver
replace door
replace top bracket / 5/16" socket
check alignment
27 of 29 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Flagstaff, AZ
Parts Used:
WPW10128551
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
The evap motor failed (no air movement inside of refrierater
Removed screws from cover tested for power to motor found power was on to motor but motor did not work. I went to your web site was able to locate part in about 5 minutes . Even with over night shipping the part came to about $50,00, far cheaper tha a service call would have been.

Thanks John Paulsell
28 of 35 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dave from dunwoody, GA
Parts Used:
W11176463, WPM0114003, WPA3223101
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
No ice in ice maker
Turn water and refrigerator off, use hair to thaw the ice maker filler tube, then remove the filler tube inside the freezer. Next remove the water supply line cover plate in back of the refrigerator. Now remove the speed clip at the white pvc elbow and pull out the supply line. Next, grasp the pvc elbow with pliers and pull hard to remove. The new filler tube is a 1 piece design (filler tube and elbow combined) and needs to be cut to the proper length. Mark it inside the freezer, remove it and cut to length. Now coat the outside flange with caulk or PU glue and snap into the opening. Put the speed clip on the elbow first and center it. Ensure that the spreader insert is in place in the plastic tube, then slide the supply line into the elbow untill completely engaged. Replace cover.
28 of 37 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Florentino from Windsor Locks, CT
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Refrigerator stopped cooling. Pulled it out of the alcove and plugged it back in. Compressor starfted but noticed condenser fan was not turning. Unplugged fridge and tried to turn the fan by hand - frozen.
Remove the back hardboard cover screws for access to the condenser fan. I opted to tip the fridge over on its side for even better access to the fan mounts and wire. Replaced the fan assy (reused the fan). Splice the wire and it's done.
27 of 36 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Janet from Hillsboro, OR
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Pliers, Screw drivers, Socket set, Wrench (Adjustable), Wrench set
Freezer and Fridge wouldnt cool
My husband replaced the condenser fan. It took awhile and a few choice words but he got it replaced. The fan seemed to work fine, but it still wasn't cooling. I noticed that when we had the fridge unplugged that water started draining out the dials at the top of the fridge under the freezer. And there was absolutely no water at all in the drip pan under the fridge. So I took the doors off and totally took the inside of the freezer apart. I discovered that the styrofoam on the floor of the freezer had become inudated with fluid and the under the foam the coils were all frozen solid with ice. Hence not allowing any drainage. I put a lamp in the freezer area and defrosted all the ice. In searching the internet i discovered that they no longer produce the foam so i went to home depot and got a piece of foam and aluminum foil and cut it to replace the ruined foam. I put the fridge all back together said a prayer and crossed my fingers and lo and behold it works perfectly now!!!!
23 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Shelley from Katy, TX
Parts Used:
D7824706Q
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Ice Maker was leaking water and causing the ice to freeze into a block
First I removed the Ice bin, I then loosened the ice bin rail under the ice maker and removed the screw that attached the bottom of the ice maker to the side of the fridge. I unplugged the power to Ice Maker from the back of the fridge and unscreewed the two screws that secured the ice maker to the fridge. This allowed the Ice Maker to be removed from the fridge. To replace the new ice maker I simply repeated the steps in reverse.
30 of 47 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
W from Nellysford, VA
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
Freezer too warm; noticed sides of refrigertor were warm
I saw on a partselect web site that these symptoms could be caused by a failed condensor fan motor. After removing the cardboard panel in back of the refrigerator I noticed the fan was not running when the rfigerator was. The fan was held in place by three brackets. I unscrewed the screws holding the fan motor to the brackets and also unscrewed one of the brackets to make room to pull the motor out. I cut the wires close to the motor. I removed the fan blade and secured it to the new motor. I had to reroute the old wires in order to have enough slack to use wire nuts to attach them to the leads on the new motor. I then re-attached the motor to the two brackets remaining in place and then re-attacehed the third bracket I had removed to get the motor out.. The most difficult part was working in a very confined space.
22 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bob from Hesston, KS
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set, Wrench set
The old motor wouldn't turn the fan.
After moving the refrigerator away from the wall I removed the cover on the lower back of the unit by removing the screws that held it in place. The condenser fan was not turning and there was heat build up in the area causing the refrigerator to not work properly creating elevated temperatures in both the freezer and regrigerator. Removal of three torx screws from the original motor was all it took to get the motor free. By turining it and working the fan blade around the mounting bracket I had the motor out in just a few minutes. Replacing the new motor was just as easy to reinstall. The fan was removed from the old motor and placed on the new for installation. The original motor was wired to accept a connector from the wiring harness of the refrigerator. I simply cut the connector off the wiring harness and stripped the insulation from the wires which easily allowed me to connet the wires of the motor and harness with two wire nuts. Three self tapping screws were used to hold the motor in place replacing the torx screws. Installed I plugged the unit in and immediately the fan started spinning as the unit came to life. Cleaned and replaced the cover over the back and slid back into its spot. Running as good as it did when it was new. Easy job to take care of.
24 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kevin from Tyler, TX
Parts Used:
D7824706Q
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Icemaker leaked water into ice bin causing a glob of ice
Philips head screwdriver and ten minutes was all it took! I removed the two screws that hold the icemaker assembly in place, then pulled it out a little and disconnected the electrical plug freeing the icemaker assembly. Then I snapped the external parts off my old icemaker assembly and snapped them on the new icemaker assembly. Installing the new icemaker assembly was just as fast and easy. I snapped the electrical plug into the new icemaker assembly, then screwed in the two screws. It was making ice shortly thereafter. Glob free ice! I'm glad I didn't call a repairman. I probably saved a hundred bucks. A ten year old could accomplish this simple and easy task. No wonder the Maytag repairman has time on his hands.
22 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Malcolm from Parrish, FL
Parts Used:
WP12579803
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Drain pan failed and had many leaks
Took two times getting the correct part, however after getting the correct part it took about 10-minutes to replace. Had to take the fan out. When you put the new drip pan in make sure it is positioned so that the guides on the pan aligns with slots in the bottom refrig brace, otherwise back pannel will not align correctly. The fan is very easy getting aligned in the new tray. May take a little effort. I do not know why the pan on a refrighterator that is less than 5-years old could start breaking into many pieces.
27 of 42 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the ASB2623HRW
16 - 30 of 631