Customer:
dave from williamsville, NY
Parts Used:
WP67005140
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
half of the freezer handle broke off
Not much to describe. Just used philips screwdriver and removed the two screws holding the handle in place. Discarded the broken handle, washed the area where the original handle was and replaced it with a brand new white handle (not yellowed with age)by replacing the two screws.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
lisa from sunrise, FL
Parts Used:
67005125
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
broken freezer Handle
I just took the old one off and put the new one on..
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sam from Las Vegas, NV
Parts Used:
WP628356
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Water Fill Cup Broke
The Ice maker unit had to be removed and the shaft had to also be removed, which required dis-assembling the motor drive. The thickness of the shaft and the bearing fill cup prevents it from simply pushing it in place. Other than that I have Ice.
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Severn, MD
Parts Used:
D7824706Q
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers, Socket set
Ice Maker was leaking
Used socket set to remove screws. Removed the wire harness, then removed lift arm from old ice maker and then put lift arm on the new ice maker. Reinstall wire harness then installed back in freeze with the screws. Video was very helpful. I will do business with Partselect in the future. Shipping was very fast. Thanks Partselect
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Carl from RIVERSIDE, CA
Parts Used:
8009
Difficulty Level:
Very Difficult
Total Repair Time:
More than 2 hours
Tools:
Screw drivers
light bulb in water ice freezer door went bad
I didn't. Don't know how to get to light bulb to change it for this specific model
7 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ben from Falls Church, VA
Parts Used:
WP65889-4, WP12555902
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
No cooling in the freezer or in the refrigerator
Remover rear cover at bottom of refrigerator. The replacement run capacitor was the same as the original one. The replacement Overload Relay Combination was slightly different. It plugged onto the compressor the same, but the connector where the power came in from the wiring harness was different. I had to cut off the original connector from the wiring harness, and then splice in new connectors onto those two wires which I could then attach to the replacement Overload Relay Combination. Fortunately the connectors I needed were fairly common and I had those available. After that it worked. My suspicion is that the Run Capacitor was fine, and it was just the Overload Relay Combination that failed. Replacing the capacitor without replacing the Overload Relay Combination did not fix the problem.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jane from Albuquerque, NM
Parts Used:
W11384469
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers, Socket set
lights wouldn't come on/work in refrigerator
Referencing the info/schematics you have on your website, I unscrewed/unattached top-front panel (carefully), from behind the panel you have to detach the wires (2) from the switch, pushed "in" the switch to remove, put in new switch and attach wires to test BEFORE remounting panel. Tada!! Thank you PartSelect! You saved me at least $80...would have been at least $100 to have a repair person come to the house!
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Winston A from Brooklyn, NY
Parts Used:
W11384469
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
Raplaced switch
Repair went well,took about five to ten minutes to disconnect the power from the fridge removed the defective switch installed the new one ,reconnected the power,,,and Let there be light and there was light!
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Aliki from Miami, FL
Parts Used:
WP628356
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Fill cup broke.
Very easy to order from parts select. Took seconds to replace.
6 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
EILEEN from TRUMANSBURG, NY
Parts Used:
WP67005141
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Freezer door handle was cracked
NEW SCREWS NOT INCLUDED with replacement handle! Removed old screws with a phillips screwdriver, cleaned them, reused screws to install new handle.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Levittown, NY
Parts Used:
WP12550116Q, WP12550115Q
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
gaskets ripped on freezer/refridge.poor seal.
I removed all food items from inside fridge/freezer doors.I then noticed how gaskets slip behind outter skin of both doors after removing all screws except a few on the top, inorder to keep from having entire door skin fall to the floor.Using back of spoon helps to properly fit gaskets into place without any rips.Using nut driver really helps with saving time and the "hairdryer" suggestion really helps with having gasket seat firmly around entire unit.Just take your time and pay attention to corners,they may need a little streching.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Linda from Johnson City, NY
Parts Used:
D7824706Q
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
leaking ice maker,big chunks ot ice were forming and had to remove them 2-3 times a day
removed old ice maker by taking out a couple of screws in the back of freezer,when new ice maker arrived i saw that it didn't have the same hose apparatus as old one so I easily took apart old one then took apart new one and switched them out-very-- easily done for a 61 yr old lady I might add-- also had to reinstall ice maker arm off old ice maker as new one does not come with one Then installed new ice maker in freezer I am very very pleased,sure saved a lot of money doing it my self
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Walt from Van Nuys, CA
Parts Used:
WP10442411
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Socket set
No ice cubes from ice cube maker
Happen to locate your site by Google. Was impressed and really pleased to find a schematic and directions to find and remove and specs to test the water valve and Defrost thermometer using an electric multimeter. You cannot tell by "looking" at a component if it is still OK.
So I put all the freezer contents into my beach cooler. The repair went as follows.
1. Removed the 6 screws from the back panel and pulled it out of the way.
2. Located the defrost thermostat and pulled it off of the coil.
3. Pulled the two connections off and took it to the bench to test. It showed no readings indicating it was dead.
4. Ordered a new one which came in two days.
5. Had to change the electrical connections using wire nuts.
6. Reversed the process plugged the refrigerator back into the wall. It started and later on I was getting ice cubes.
A great experience. Don't mess with repair guy as they normally are not up to speed on all devices and you are paying for them to learn how to repair your appliance in several trips. Probably using this site. If you can follow instructions, you can do this stuff.
Note. I tested the Water valve using given instructions. More time is used moving things around than the actual repairs. I avoided $150.00 for a new ice maker unit.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Denver, NC
Parts Used:
D7824706Q
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Water overflowing ice maker
Removed the 3 screws that hold the ice maker in place and remove the cover and level wire. Put the cover and wire on new part and install the 3 screws. Had ice within 1 hour. A very easy job for the do it yourselfer. Suspect the heat coil that melts the cubes was not working in the old unit and cubes stayed in the tray.
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Emmitsburg, MD
Parts Used:
WP10442411
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
The refrigerator was warm/ freezer back frozen
Pretty simple really after reading online some other owners' experiences. This is a bottom freezer unit. Remove the ice maker, the tray slides, and the back cover of the freezer box. In my case I had to thaw it out with a hair dryer as the cover was frozen in place. I checked the old 'stat and found it was bad; I temporarily wired the leads together until the new 'stat arrived. It does allow the refrigerator to warm up during a defrost cycle but it beats de-icing it twice.The defrost 'stat is clipped over the refrigerant line in the upper right corner of the box. Resistance was 65k ohms and wouldn't close on low temp (tested by clipping it to an exposed refrigerant line in another upright freezer) but there was no obvious damage. The one lead on the replacement 'stat has the wrong connector so you have to cut off the original lead from the old unit and splice it on the wrong lead on the new one. I used an epoxy sealed heat shrink type butt splice. Reassemble and let it run. One word of warning: be careful tightening any screws as they will strip easily
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!