James from Denver, NC
Parts Used:
D7824706Q
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Water overflowing ice maker
Removed the 3 screws that hold the ice maker in place and remove the cover and level wire. Put the cover and wire on new part and install the 3 screws. Had ice within 1 hour. A very easy job for the do it yourselfer. Suspect the heat coil that melts the cubes was not working in the old unit and cubes stayed in the tray.
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Lora from Taylors, SC
Parts Used:
10783803
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
The deli frame broke on one side where the screws attach.
First took the shelving unit and deli drawer out. Then removed the screws that were still attached. Took off the broken frame and replaced with the new frame. Put the screws back and put the unit back in the refrigerator.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Eric from Woods Cross, UT
Parts Used:
12452602Q
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Broken wheel
Removed pin holding the wheel along with leveling screw. Put new wheel in place, replace pin and screw. Done...very easy.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Raymond from Annapolis, MD
Parts Used:
WF401S
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
water filter was getting clogged
The filter is self-clogged when you un-wind it for replacement, so no complicated system shut-off was required in order to replace it.
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Trevor from Glendale, AZ
Parts Used:
WP10111905
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Ice crushing auger had come loose and cracked front panel and ice bucket
Reassembled auger assembly to new ice bucket with new screws. Fairly simple and straight forward.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Aliki from Miami, FL
Parts Used:
WP628356
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Fill cup broke.
Very easy to order from parts select. Took seconds to replace.
6 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Daniel from DAVISBURG, MI
Parts Used:
D7824706Q
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Ice maker stopped making ice
Remove 1 screw under ice maker. Gently pull downwards to unhook ice maker. Disconnected 4 pin wire connector. Remove and set aside the cover and wire loop you will need on new ice maker. Reverse the steps to install new maker. Once new ice maker is installed you will have to wait 2-4 hours for ice. There is a thermostat that will need to reach 10 degrees F to operate.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Winston A from Brooklyn, NY
Parts Used:
W11384469
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
Raplaced switch
Repair went well,took about five to ten minutes to disconnect the power from the fridge removed the defective switch installed the new one ,reconnected the power,,,and Let there be light and there was light!
5 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mason from Tallahassee, FL
Parts Used:
R0181181
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Cam snapped in half on bottom of door
Super easy - emptied door of all food, unscrewed bracket from top of door, lifted door off and set aside. Broken cam removed, new one screwed in, and lubed with some Vaseline. Set door back in new cam, screwed bracket into the top, and good to go. I was kinda worried about shopping from PartSelect since I had never heard about them, but the part was here in less than 2 days. Pretty awesome little company.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
paula from julian, CA
Parts Used:
R0181181
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
door would not self close tightly
Remove two screws from top door hinge.
Remove door from unit
Remove old broken plastic cam 1 screw
Replace new door cam tighten 1 screw
Reinstall door and top hinge screws.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jane from Albuquerque, NM
Parts Used:
W11384469
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers, Socket set
lights wouldn't come on/work in refrigerator
Referencing the info/schematics you have on your website, I unscrewed/unattached top-front panel (carefully), from behind the panel you have to detach the wires (2) from the switch, pushed "in" the switch to remove, put in new switch and attach wires to test BEFORE remounting panel. Tada!! Thank you PartSelect! You saved me at least $80...would have been at least $100 to have a repair person come to the house!
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
riley from CAVE CREEK, AZ
Parts Used:
WP65889-4
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Socket set
Refrig began to trip the GFI circuit in the garage. When plugged into a house interior circuit the lights and fan ran but no cooling in either the freezer or frig.
First of all I want to thank Michael from Carlisle,PA and this site for publishing Michael's info on the wiring specifics on the new 3 connector Start Relay ( WP2262185 ). The original relay only has 2 connectors The 2 orange wires which are combined to one female connector need to be clipped and separated each to its own connector. Refer to Michael's blog as to which wire goes to which connector on the Start Relay. I replaced the Run Capacitor, Start Relay and Overload just to be safe. The Start Relay was the actual culprit.Thank you for an excellent website!
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dennis from Lawton, OK
Parts Used:
B8380901, 12002642
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers
Ice Dispenser Actuator Arm Damaged.
0. Tools required: small Phillips screw driver and a normal length 3/16th inch Nut Driver. Some duct tape would be handy as well - for securing the wiring housing out of the way.

1. Unplug the refrigerator or trip the controlling circuit breaker to remove the possibility of an unpleasant surprises such as electrical shock, electrical arc, further damage to the refrigerator, burns to yourself, or death.

3. Remove the two small Philips-head screws located on the under side of the bezel surrounding the ice and water dispenser.

3. Carefully lift, pull, and remove the bezel.

4. Note the locations and relative positions of all the components behind the bezel. A digital photograph (or three) from various angles for future reference when reassembling the dispenser would be a good idea - if a camera is available.

3. Remove the two screws that hold the plastic housing and metal shroud containing wiring and switches. Tape the shroud and housing together and tie or tape it out of the way. If you ignored step #1, make sure you tape both the plastic tray and the metal shroud together as they were installed so that you cover any exposed wires or connectors inside the plastic housing. All the switches will still be "hot" and can cause the dispensers to activate at unexpected and mostly inconvenient times.

4. Slip the ice door damper spring (wire loop) off the ice door mechanism. Do not abruptly push or pull on the damper spring loop when it is disconnected from the door mechanism - you may damage it.

5. Remove the two screws that hold the retaining tabs in place for the water dispenser activator; the two screws that hold the retaining tabs in place for the ice dispenser activator; and the two screws that hold the spring-loaded ice door-closing mechanism in place. That is a total of six screws: four retaining tab screws for the activators and the two screws retaining the spring-loaded ice door mechanism.

6. Slip the water dispenser activator arm down, off the water feed tube, and put it aside.

7. Remove the ice dispenser activator arm and spring-loaded ice door- closing mechanism as a unit and note how it is fitted together. Then remove and put aside the ice door and closing mechanism. Save the spring-loaded ice door closing mechanism for reinstallation with the new dispenser

8. Reinstall the new water dispenser activator arm over the water feed tube and reinstall the metal tabs and tab retaining screws.

9. Assemble the new ice dispenser arm and the existing spring-loaded ice door- closing mechanism as you noted it to be during the disassembly process.

10. Reinstall the new ice dispenser activator arm and spring-loaded ice door closing mechanism. It seemed easier to secure the dispenser activator with the screws and metal tabs first and then the spring-loaded ice door closing mechanism.

11. Reinstall the plastic housing containing the electrical components and the metal shroud and secure in place with the two screws that were removed in Step #3. Restore electrical power to the system.

12. Test both the water dispenser and ice dispenser for proper operation. If both dispensers appear to operate correctly, reinstall the bezel with the two small Philips screws and you are done.

13. If either of the dispensers does not work, you will have to trouble shoot the problem. A common problem seemed to be that the activator arm was not making contact with the switch in the plastic housing. You will have to go back and ensure that all the components are properly installed - there are no other adjustments and simply pushing harder on the actuator may break the newly installed part.

All the screws and components are easily accessible, so I think that the entire repair process should take about 30 to 45 minutes unless Step 12 fails and Step 13 is required. Then it may take a couple hours to figure out and get things set right.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ross from Sun Lakes, AZ
Parts Used:
D7824706Q
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Ice cubes in bin frozen into big lumps due to water leaking into bin from icemaker. Lining of icemaker cube tray worn and damaged allowing leak.
Pull refrigerator out from wall to shut off water and power. Remove ice bin, pulling front down then out. Remove screw at bottom of icemaker, then pull down to release two clips, Pull out a couple inches to get hand behind icemaker to release wiring harness connector. (squeeze top and bottom to release clips). Remove unit. Remove wiring harness and wire bail from old unit and install on new unit. Reverse steps to install new unit. Make sure ice bin is fully inserted, or unit will not function.
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Marshall from Marrero, LA
Parts Used:
WP12740302
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Socket set
Ice Maker Auger
Wow! less Than 15 mins to install, called partSelect and within two days the Auger arrived and with handy socket it was done!
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!