TM16M1 (P7859210W) Amana Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Judith from Phoenix, AZ
- Parts Used:
- 8009
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Bulb Replacement
I pulled down the wire around the glass cover. . . Released on end of the wire from its holder being careful to not let the glass cover drop. Unscrewed the bulb and replaced with replacement. Easy, easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jim from Milford, DE
- Parts Used:
- WP10442411
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
freezer coils would frost up and block flow of air
Emptied the contents of the freezer
Removed the panel covering the coils and fan
Since I suspected the thermostat, I removed it and tested for continuity. When it was constantly "open" I decided it was defective, and ordered a new one from PartSelect.
As an interim fix, I connected together the two wires that had been attached to the thermostat, so the fan ran constantly.
When the part arrived, I connected it, replaced the cover panel and monitored the temperature for a day to verify that it maintained below freezing.
Removed the panel covering the coils and fan
Since I suspected the thermostat, I removed it and tested for continuity. When it was constantly "open" I decided it was defective, and ordered a new one from PartSelect.
As an interim fix, I connected together the two wires that had been attached to the thermostat, so the fan ran constantly.
When the part arrived, I connected it, replaced the cover panel and monitored the temperature for a day to verify that it maintained below freezing.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ryan from Burnsville, MN
- Parts Used:
- WP10442411
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Coils frozen up completely in freezer
I unplugged the old thermostat and tested it with my meter and found it was always closed. I hooked up the new thermostat and the ran the defrost cycle and I now had heat in the defrost heater and the problem was solved.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from Morgan, UT
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
noisey fan
yup
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jackie from Nova, OH
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Switch was not working after a repairman had fixed something else
Please bear in mind I am 65 years old & it was harder to get up & down off the floor then to change the switch. Was very easy - watched video, unplugged unit. I used the putty knife at the right front corner to work loose, when it came loose had to loose the left side a little. The unit pulled out easily. detached the wired that had a single plug with 2 prongs on it. Attached the plug, pushed new switch into place. There was no way you could place wires on wrong prong. When done, plugged refrigerator back in & checked if working. I CAN SEE THE LIGHT and the food in the freezer now. Thank you for making an easy repair.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Adam from Randolph, ME
- Parts Used:
- WPW10662129
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers
Frig not cooling.
After plugging in the new relay to no avail. I replaced the thermostat. That fixed the problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Steve from River Edge, NJ
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
exchange of defective light rocker switch
1)pry out the old/defective light rocker switch with a screw driver (flat head) and pull out the cables 2)unplug two connectors at the end of light rocker switch 3) connect new light rocker into two connectors 4)push the wires inside and put back new light rocker switch
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Anthony from Fairport, NY
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Light in the refrigerator didn't work
I did exactly as the video showed. I popped out the old switch, disconnected the two terminals, connected the new switch and put it back. The light now works! The refrigerator is over 25 years old and the switch works! What a great website this is. Couldn't of done the job without Partselect's help.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mary from Wasilla, AK
- Parts Used:
- W11384469
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Light switch in the refrigerator was faulty from the first day we installed the fridge.
I had ordered some other parts for something entirely different off your website and service was great. So after almost ten years of a dark refrigerator, because of a defective switch, I decided to see if you had the part to fix it... You did and the part got here in 3 days. I had a working light switch and all the light in the world where my husband needed it most (in the fridge). It took me at the most ten minutes to replace the part. All is well now and I have a happy husband who can find the leftovers just fine. Thanks for your great service!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Irene from Whitehall, MT
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
No light in frig
We tried repairing with a new switch which was very easy to install but it didn't fix the problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dora from Rock Island, IL
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
light would come on and off
Viewed the viedo - it showed what to do
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dennis from Lawrenceville, GA
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Light switch which turns on the lights when the door opens went out
This is an easy fix, simply remove and replace. What I was impressed with is that a how to video was provided along with my part. I wish all manufactures would offer this, the video was easy to understand and you had a good view of the operation. Thanks, a job well done.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from LAS CRUCES, NM
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
refridgerator was not cooling to the proper temps and finally would not cool at all
Pulled refridgerator forward away from the wall. Remove the cardboard back behind the appliance.I saw that the condenser fan motor was not working. Unplugged the appliance from the electrical outlet. Removed a 3 wire plug from the condenser fan motor. Remove 3 screws (with a nut driver) which held the condenser fan motor in place. Remove the condenser fan motor from the appliance. Looked up the part needed for repair using the appliance model number. Found which part was applicable for the appliance. Placed the order from Price Select on a Monday morning and recieved the part 2 days later on Wednesday via FedEx. The item shipped was a 2 wire condenser fan motor. Read the instructions that came with the part. Using wire cutters, cut the old 3 wire plug. The center wire is a green and yellow striped wire. Use the same colored wire that is also shipped in the box and has connectors on both ends. Cut one of the connectors off and use the wire strippers to remove plastic wire coating. Connect both ends from the appliance and the green and yellow wire that was shipped. Use a wire nut (also shipped in the box) to connect the wires. You will have 2 black wires left on the new condenser fan motor that need to be connected to the appliance. You should have an orange colored wire and another wire that is black with a white stripe. Connect one wire from the new fan motor to the orange wire and use a wire nut to attach both wires together. Use the other black wire from the new fan motor to the black/white striped wire from the appliance. Use the wire nut to attach both those wires. Place the new condenser fan motor back in the appliance using the screws that come with the motor. Attach the green and white wire with the connector on the end to one of the 3 screws that hold the motor in place and secure the screws. Use the electical tape to hold the wires all together and away from the fan motor. Plug the appliance into the outlet. You can see the condenser fan motor working properly. Note that when connecting the 2 black wires from the new condenser fan motor to the orange and the black/white wire from the appliance, for my appliance, it did not matter which wires were connected as the fan motor was a clockwise motor. Place the cardboard appliance backing, back on to the appliance and push the refridgerator back in place. Allow about 5-6 hours to get the freezer to between 0-5 degrees. The refidgerator should be between 34-38 degrees and will take a little longer to get to that projected temp.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Don from Laramie, WY
- Parts Used:
- W11384469
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
Switch didn't work
followed the video as instructed. Saved two repairman calls, one to find the problem, one to install. Net savings was about $130.00
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Frank from Scranton, PA
- Parts Used:
- WP10442411
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Freezer was cold, refrigerator was warm
Removed panel at rear of freezer. Defrosted evaporator coil. Removed and replaced bimetal defrost thermostat. Had to replace the connector on the male lead wire in the freezer as the part supplied had a different type of connector than the original thermostat. Replaced panel at rear of freezer.
Was this instruction helpful to you?
Thank you for voting!