anthony from HAVELOCK, NC
Parts Used:
W11384469
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
changed the light bulb still would not work so I figured it was the switch sure enough.
I took a chance and ordered a switch that is next to the top of the door. looked for how to remove it easily done in ten minutes works fine last long time.
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ross from Sun Lakes, AZ
Parts Used:
D7824706Q
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Ice cubes in bin frozen into big lumps due to water leaking into bin from icemaker. Lining of icemaker cube tray worn and damaged allowing leak.
Pull refrigerator out from wall to shut off water and power. Remove ice bin, pulling front down then out. Remove screw at bottom of icemaker, then pull down to release two clips, Pull out a couple inches to get hand behind icemaker to release wiring harness connector. (squeeze top and bottom to release clips). Remove unit. Remove wiring harness and wire bail from old unit and install on new unit. Reverse steps to install new unit. Make sure ice bin is fully inserted, or unit will not function.
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Atlantic Beach, FL
Parts Used:
R0131577, WP10442411
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Circuit Breaker tripped/shut down frig. every 8 hrs when time switched on
Removed timer kit (this was the second time for this part)/ replaced - this is a fairly simple job and take 5 minutes. The defrost thermostat take about 10 minutes to get to and take out the old one, replacement is a 2 minute job, unplug and replace, the longest part of this job is getting the back of the freezer off and then replaced, but it is fairly simple to do. Total time to diagnose about 15 minutes, replacement parts arrived in 2 business days, replacement time 15 - 18 minutes total. Recommend getting the thermostat and timer together. The first time this happened, only order the timer but I think the problem was the thermostat all along and the time seemed to be operating but when it came on every eight hours it tripped the circuit breaker Not sure which was really the problem, but all working fine now.
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Gurnee, IL
Parts Used:
D7824706Q
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Old Ice Maker failed
I removed the old ice maker and during the short disassembly noticed a burned out connection to the heater element that allows the ice to be broken free of the tray and dumped into the bin. Part Select had a new unit to me next day! I had watched their short install video, and read some of the user comments, already. Re-installing the new unit was a snap, and just as the video had described except for the mount bracket. The only thing that concerned me was that the new unit did not immediately do anything. I began to investigate and found that the flexible water "chute" connection had ice in it! I unplugged the refer, unscrewed the water filter and drained it. I disconnected the water feed on the outside back of the unit as well to make sure water could flow easily to the ice maker port. I filled the water filter with boiling hot water and replaced it, I plugged in the refer, and reprogrammed the date and time. Several hours later I checked the ice maker and it was -- making ice!
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tonya from Grand Prairie, TX
Parts Used:
833697
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
Refrigerator quit cooling and the freezer wasn't freezing anything
Order the part from the Internet on Sunday, it mailed out on Monday and I received it on Tuesday. I unplugged the fan then undone 3 screws that held the fan bracket to the refrigerator pulled it out unscrewed 3 more nuts and replaced the fan on the bracket and I cut the old wire plug off the old fan and with 2 wire nuts put it on my new fan. Replaced the fan and bracket back on the refrigerator plugged it in and it works like a new refrigerator.
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Douglas from Simsbury, CT
Parts Used:
WP10442411
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Pliers
The upper refrigerator section was warm, but not the freezer
The refrig seemed warm so I checked the temp of some liquid with a thermometer. Readings were above 60 degrees and I knew food would spoil soon. I vacuumed the dog fur off the cooling coils underneath the machine to see if that would help. Nope. I realized cold air from the freezer was not reaching the refrig. The fan was working but no cold air was coming out. I figured a blockage either in the air duct from the refrig or in the return duct to the freezer. I didn’t see any blockage in the refrig section. I took everything out of the freezer and removed the back wall. The cooling coils were completely frozen solid with frost. Being a frost free machine, I knew there were heaters that were controlled by a timer that melted this frost away periodically and that this cycle was no longer working. I found a schematic on the web, maybe your site, and educated myself on the heater circuit. The circuit consisted of a timer, thermostat near the coils, and a cal rod heater all wired in series. The timer was easy to get to and being a mechanical device I figured it must be the culprit. I ordered one online. I checked its operation and it worked fine. Realizing time was short, I hot wired the cal rod around the thermostat and rotated the timer to its heat position. The frost melted quickly and I put the freezer back together and ordered a thermostat. I canceled the timer order. When it arrived, I installed the new thermostat and it has worked fine for the past month. A little colder than usual as I don’t yet have the settings back to where they were. I have checked the operation of the old thermostat. It’s supposed to close at 30 degrees and open at 45. I have done a continuity check on it by putting it in the freezer, letting it cool down, take it out, let it warm up and it seems to work fine. So I have doubts if I really solved the problem. Wire connections were tight and not corroded. Maybe the timer was hung up on debris that I freed by cycling it. I don’t think this is the end of the story.
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
richard from colorado springs, CO
Parts Used:
D7824706Q
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers, Socket set
Ice maker stopped functioning
Part received was what I needed. There was one issue--the 'feed' opening to receive water and direct it into the ice tray was a side feed and what I needed was a back feed. That means I had to do some exchanging of parts to make it work. That exercise took more time that the actual installation.
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Westfield, MA
Parts Used:
WP10442411
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Abnormally warm temperatures in freezer/fresh food section
After unplugging the appliance I needed to thaw a large ice buildup off the evaporator cover panel before I could even remove the panel. The freezer being on the lower part of the appliance has the evaporator mounted vertically and it was 100% encapsulated in rock hard ice. It took over an hour to thaw the ice and collect all the water with a shop vacuum, since the condensate pan began to overflow.
One thawed, I checked all wiring for good connection, checked heater, defrost thermostat, timer unit with multimeter. The defrost thermostat checked out fine after putting it into another freezer for a 15 minute cooldown, but I noticed a crack in the seal and suspected internal moisture and decided to replace that part. A simple plug in of two leads to the new part after clipping it to the evaporator, replacement of the panel, and the appliance was up and running problem free.
A workbench disection of the old part confirmed my assessment, it had internal rust and water and had failed causing the defrost cycle failure.
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
kurt from Westminster, CO
Parts Used:
D7824706Q
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Ice maker not working.
This was a very easy repair. Of course start by unplugging the power cord. Take out the lower freezer drawer. Unplug the wiring harness from the ice maker at the rear of the freezer. Undo 3 screws with a 1/4" nut driver. The ice maker will come right out. You don't have to undo any water connections, the feed tube just slides into a guide in the ice maker. Once the ice maker is out, unplug the harness from the old one and snap it into the new one. Same with the cover. Reassemble in reserse order. Plug the power cord back in and wait a couple of hours for the familiar sounds of ice cubes falling into the tray.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ed from The Dalles, OR
Parts Used:
R0131577, WP10442411
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
The refrigerator would cool for about a week then quit If you turned it off for a day it would work for another week.
I took the cover off of the evaperator in the back of the freezer compartment and thawed the ice out with a heat gun. I then replaced the bimetal defrost timer I did have to change one connection as it would not plug into the harness.
I found the Defrost timer in the front of the refrigerator behind the filter cover at the bottom. Just one screw and a quick plug in and everything is working wonderfully. no more icing up
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Doug from Lewisville, TX
Parts Used:
D7824706Q
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Ice maker putting black pieces of plastic in the ice
Replaced ice ice maker using
All of the instructions on the website.
Very easy. A couple of the screws I had
To feel for because I couldn't gety big head
In the freezer far enough to see them.
Very simple and only took about 15 minutes.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
sally from WAKEFIELD, RI
Parts Used:
WP67005141
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
broken freezer door handle
unscrewed the broken one, screwed the new one on. SIMPLE SIMPLE took 30 seconds.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from Roseville, CA
Parts Used:
W11384469
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Door light switch disintegrated
Very simple fix, remove 3 screws, two connectors to the old switch
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Peter from Lancaster, PA
Parts Used:
D7824706Q
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
water leak and frezes ice in bin
to easy to describe, remove 3 screws and a wire plug then install new unite.
Works great
Thanks
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
robert from COLDSPRING, TX
Parts Used:
D7824706Q
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice tray filled up with water. Stopped making ice.
As per instructions. Removed parts from old ice maker, and installed them on new one, Then installed it in the freezer. Works good.
2 of 2 people found this instruction helpful.