- Customer:
- jeffry from peabody, MA
- Parts Used:
- WP2315539
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers
the fride section was not geeting cold the Fan was not turnin on
first remove ice maker 1-screw on the bottom all the way out and two screws on the top half way out slide up and out and unplug wiring as you remove then remove back panel unplug ground wire remove screws that hold fan assembly unplug wiring remove pressed on fan blade put new motor in reasemble and it was good to go
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Angela from Renton, WA
- Parts Used:
- WP2315539
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Evaporator fan needed replacing
I actually followed the instructions by William. He did a great job. I ran into some difficulty because the wire connector on the replacement motor didn't match the old connector. We had to replace the connector on the new motor to match the wiring harness, which was easier than trying to match the connector on the motor. Had the connectors matched, the replacement would have taken less than 30 minutes to complete.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- JOHN from WILLISTON PARK, NY
- Parts Used:
- WP2315539
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
no refrigator cooling
First i pulled the electrical plug from the socket so the refrigator was off than I removed 5 screws (3 of those holding the ice maker). pulled the icemaker toward the front and removed it I than took off the back of the freezer panel,(the back panel was removed by pulling the top of the panal towards me it came right out of the freezer) I removed an additional 2 screws holding the evaporator fan motor. Than I used pliers to squeeze the mounting bracket tabs (white tabs BOTTOM OF MOTOR BRACKET). I then disconnected the electrical FAN MOTOR PLUG and removed the motor. i than pulled the fan blade from the motor (fan blade is only a pressed onto the motor shaft.I than pressed the fan blade back unto the fan motor and reversed the above directions
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Heather from Marysville, WA
- Parts Used:
- WP2315539
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Refer wasn't cold but freezer was working great
Removed the ice maker (3 screws) removed the back plate (2 screws) Remove the bracket holding the fan in (2 screws) Remove the rubber mounts on the old motor and the fan itself off the old motor. Then put it all back together in reverse order.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Vernon from Carmel, ME
- Parts Used:
- WP2315539
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
refrigerator section was not cooling
unplug, turn water off, remove ice maker & unplug,remove back panel remove old fan unit & unplug remove fan remove fan blades just pull off install new fan, put fan blades on new fan & install on bracket & re install plug in re install back panel. plug in ice maker re install ice maker . turn water back on plug refrigerator back in ( quite easy )
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Deravine from New London, CT
- Parts Used:
- WP2254618
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Wrench set
the part was loos
the repair it good and easy ,vo helper to do it.