- Customer:
- Kevin from Whitehouse, OH
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Ice Maker didn't make ice
Very easy to install the new ice maker. Removed the bottom screw holding the ice maker to the side of the freezer. Loosened the top two screws. The old ice maker came off just like that. Unplugged the power supply from the freezer and removed the whole apparatus.
I saved the wiring harness, screws, cover, and metal arm from the old ice maker. Installed these on the new one and mounted the new ice maker in the freezer. Done.
The only issue I had was that the water supply hose got kinked when I pushed the fridge back into place. Once that was resolved, the new ice maker started happily making ice.
I saved the wiring harness, screws, cover, and metal arm from the old ice maker. Installed these on the new one and mounted the new ice maker in the freezer. Done.
The only issue I had was that the water supply hose got kinked when I pushed the fridge back into place. Once that was resolved, the new ice maker started happily making ice.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joseph from MILFORD, CT
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
not making ice
the diagnosis was the most difficult step.. and trusting that the one visible nut was the only thing holding it on.. (there are 2 other clips that you need to use a little force on to detach). remove the ice maker (one nut, 2 clips, detach plug).. then remove the 3 screws holding on the 'face' , pry face off, you will see where the 'contact' has burned/melted/worn away. replace unit. 80% of the time, this is the problem (according to my research)
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from WINAMAC, IN
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
non stick coating coming off in ice cubes / cubes wouldn't come out of tray
Five minutes with a phillips screw driver and the cube maker was changed. . . In the process, I failed to unplug the unit, and shorted the fill valve in the back. Again, five minutes with a nut driver and it was changed. No need for a PHD or the cost of a service technician for either job.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Barry from FORD CITY, PA
- Parts Used:
- WPW10662129
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Freezer occasionally had a temperature alarm.Clicking noise also.
Was told capacitor was problem 90% of the time.Capacior was not the problem.Bad start relay.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from NORTH HAVEN, CT
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Not all ice cubes were coming out of tray. Water was freezing from maker into cube catcher
Remove bottom screw loosen 2 top screws unplug connector from back of icebox. Lift up and pull forward. Swap front cover full bucket stop bar and wire (plugs in) reinstall 10 minute job
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Adam from GLOVERSVILLE, NY
- Parts Used:
- WPW10662129
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Plugged it in.
Not so good that was not the problem. Fan is not seized and all the lights work and display is not on but lights up as well. No start once plugged back in after 15 minutes of being unplugged. Nothing same no change.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas from Hicksville, NY
- Parts Used:
- WP10442411
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Pliers
Referigerator section was warm, freezer cold
I removed the back cover in the freezer section by removing six screws. The entire coil, the thermostat and the lines were all iced over. I used a hairdryer to defrost everything. I removed the thermostat by uncoupling the connectors and unclipping it from the coil tubing. I found the thermostat was bulging and deformed. I jumped out the thermostat using an insulated clip lead. I taped it so it would not short to anything. I plugged the unit in, turned the unit to "1" and advanced the defrost timer to defrost. I could hear the water hissing on the coil. I ordered the thermostat. It arrived in 3 days. The new one had a different terminal. I cut off the matching one from the old part and used a scotch-lok to make the connection to the new part. I slapped it in, dressed the wires and replaced the cover. I noticed that when I advanced the timer after replacing the thermostat, it did not immediately come on. The thermostat has an operating temperature window. I checked it several days later and found no frost. Everything works great.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Colorado Springs, CO
- Parts Used:
- WPW10662129
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
freezer and refrigerator compartments not cold enough
Used the suggested problem list here to narrow down that the repair was most likely the run capacitor. Poped the new one in and I now have better control of my compartment ranges. I have a temperature gauge in each compartment. Check them every opening of the doors.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jim from Gainesville, TX
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Water leaked into ice bin causing big ice chunks
I disconnected power, turned off water supply, removed three hexhead screws, disconnected wiring harness plug, then reversed procedure. New icemaker seens to be a little slower in making cubes. However, the cubes are clean, perfect shape and THEY DO NOT CONTAIN ANY OF THE BLACK COATING AS THE OLD ICE MAKER CAUSED. THIS WAS A FAIRLY SIMPLE TASK.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Nancy from Englewood, FL
- Parts Used:
- D7824706Q
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
install new icemaker
First had to remove baskets and door from freezer. Removed three screws; removed old ice maker; Attached new ice maker with three screws; removed arm from old ice maker and placed in the new ice maker. Replaced door and baskets
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jacqueline from LEXINGTON PK, MD
- Parts Used:
- WPW10662129
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Pliers
No cold
Like you video
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bill from Granite Bay, CA
- Parts Used:
- D7824706Q
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Leaking water every time ice maker fillls.
Replaced entire ice maker. Turn off water where it comes out of the wall. Loosen two top screws and remove one screw at bottom. Lift unit up and off top screws and swivel out to the right and disconnect power plug from freezer. Warning new unit does not come with: 1. Power Cable 2. Front plastic cover. 3. Wire bail. Install in reverse order Do NOT toss old unit until new one is installed and working. My came with the bottom mounting bracket bent so I just used the old one. When installing old power cable into new unit be sure to put small sensor into clip. It's part of the cable harness assembly.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Edward from BILLERICA, MA
- Parts Used:
- WP10442411
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
The fridge was running constantly. O
Once I removed the contents of the freezer I found ice on the inside back panel Removing the panel I found ice on the cooling coils and the defrost thermostat was bulged out where the wires were attached.I removed the panel with the nutdriver as shown in the video. I removed the ice maker connection and removed the panel from the freezer section. I then had to manually defrost the area with a heat gun. The ice had actually covered the Defrost Thermostat - which was bulging where the wires were attached.. The defrosting took the majority of the repair time - the actual Defrost Thermostat replacement only took about 20 minutes once I could get to it. I spliced the wire with a crimping tool as discussed in the video. Once all was defrosted I reversed the operation.Overall, a very simple part change out. The video was extremely helpful - if nothing else to mentally prepare me for the task.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jim from WAUSAU, WI
- Parts Used:
- D7824706Q
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Damage to non-stick coating caused water overflow
Repair was as shown in the video except my refrigerator had screws instead of the plastic clips as shown in the video. Just had to loosen the two upper ones and remove the one lower one. All other steps were as shown in the video.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from SPANISH FORK, UT
- Parts Used:
- D7824706Q
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Old Icemaker Leaked
Replaced Icemaker
Was this instruction helpful to you?
Thank you for voting!