Models > TRI18E > Instructions

TRI18E (P7466017W) Amana Refrigerator - Instructions

Jump to:

All Instructions for the TRI18E
31 - 45 of 138
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Tonya from Grand Prairie, TX
Parts Used:
833697
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
Refrigerator quit cooling and the freezer wasn't freezing anything
Order the part from the Internet on Sunday, it mailed out on Monday and I received it on Tuesday. I unplugged the fan then undone 3 screws that held the fan bracket to the refrigerator pulled it out unscrewed 3 more nuts and replaced the fan on the bracket and I cut the old wire plug off the old fan and with 2 wire nuts put it on my new fan. Replaced the fan and bracket back on the refrigerator plugged it in and it works like a new refrigerator.
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from Farmington Hills, MI
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Bad fan motor
Pop off six mounting screws and the ground screw. Remove the fan blade and reattach. Reinstall. Save yourself big bucks.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Paul from East Northport, NY
Parts Used:
4318047
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set, Wrench (Adjustable)
Ice maker working with no production of ice
Turn off the water source and unplug freezer. Remove copper tube and then remove valve from back of refrigerator. Disconnect plastic tube and power connection. Mark power connection plug top with a "T", this reminder helps with the new valve. Plug power and plastic tube into new valve and screw assembly back into refrigerator. Using a wrench, connect copper tube into valve. Restore water source and plug back in in freezer. Within a couple hours, ice production was back.
Like the other repair stories (that helped me), this job was very easy.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Walton from Rainbow City, AL
Parts Used:
R0131577
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Not Cooling or freezing
Most difficult part was finding where they hid the defrost timer. (it is in the left front under the fridge behind the kick panel.) just unscrew the two fastener screws from the front, tilt fridge up on one side, slide timer bracket back and remove. Unplug and remove timer from metal bracket. Replace timer and remount bracket.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Karl from Wellesley, MA
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Fan was noisy - bearing had failed
It's self-explanatory. The procedure is obvious; it's just a little difficult. The only hard part is attaching the mounting brackets to the fan. If you can't tighten the mounting bolts, loosen them and reposition the brackets. You might end up mispositioning them at first, because they are hard to reach.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Greensboro, NC
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Outer case of freezer was heating up, not making ice (sometimes) turned up thermostat several times (especially freezer)
I got the product very quickly. (thank you) Looked at online instructions that were quite vague. Pulled plug.Removed the holder for the fan motor slid it out to see what I had. Removed the mounting screws (3) and slid the motor an fan blade out. I made a cut between the wires and marked the "top" wire to motor to be sure to spin in right direction. Removing fan blade hold down clamp was NOT explained at all but I noted that the shaft on the motor was threaded, so I used pliars and held the shaft white un-screwing clamp. I cleaned the fan blades with degreaser and scraped edges of opening on holder opening. Make sure to use ALL the NEW parts included with this kit when re-installing. They send them for a reason. When slpicing and connecting wires it is a 50/50 shot if you don't mark before cutting. You can connect and try plugging fridge back for moment and make sure it is blowing OUT. Put everything back together and after turning DOWN the thermostats twice, fridge is back to usual. Ice maker is cranking out ice and outside case is cool to the touch.

Note: This can be a DIRTY job especially with 4 dogs in house. Fir and grease don't mix well
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Samuel from ALEXANDRIA, VA
Parts Used:
WPB5705307
Difficulty Level:
Difficult
Total Repair Time:
More than 2 hours
Ice from icemaker taste metallic; new ice maker directly from box
I did not do the repair yet, there is no schematic on how to route the hose; also no description of how to do the routing/connections.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Randy from Yale, OK
Parts Used:
4318047
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Wrench (Adjustable)
ice maker quit working
Replaced the water valve. I knew that the ice maker was working by watching the movement. It was not getting water to it, s I figured it was the electric water valve and sure enough, that fixed the problem.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
craig from maple grove, MN
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
noisy fridge, perimeter of door heating up
figured out the condenser fan was kaput. Tried WD, worked for several days then gave out completely. Took off back of fridge and trained small fan on compressor while I ordered new condenser fan. The swap was easy, undid the housing bolts, stripped off the connector, reconnected and voila! works perfect.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Granada Hills, CA
Parts Used:
833697
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
refrigerator was overheating, condensor fan dead.
First I removed all the screws from the back cover.
2nd removed fan nut and fan blade
3rd removed fan bracket
4th I traced wire to the condenser and disconnected wires from wire nuts.
Installed existing fan brackets to new motor kit
then reconnected wire nuts to new motor cord
Reinstalled fan nut and blade,
reinstalled cover, plugged it in and BAM .WORKS PERF!
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joseph from Bloomfield Hills, MI
Parts Used:
4318047
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers
Old Valve was dead
This was very easy and pretty fast to do and its working great...all for $40 bucks ! you can do this...trust me!
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Vincent from CHICAGO, IL
Parts Used:
WPA3073101
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Light over range burned out
Philips screwdriver
Removed screw (1)
Removed light bulb
Put in new light bulb
Closed door to bulb compartment
Returned screw.

Pro tip! Check how many bulbs you need before ordering. Mine only needed two. I got two. I suspect I’ll buy a new microwave before new bulb burns out again. Ordering/delivery was fast. No need to have spare on hand.
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Janet from PITTSFORD, NY
Parts Used:
WPA3073101
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
No problem
I had a son put in the new light bulbs. Rather simple
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
LARRY from Lexington, KY
Parts Used:
R0131577
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
The refrigerator was not cold, and the iceceam in the freezer section was soft.
First I removed the cover to the evaporator in the freezer section and found the coil iced up, then I turned the defrost timer until it clicked into the defrost mode, the heaters came on so I left the timer in the defrost mode to defrost the coil, it stayed on and did not change. The timer motor was bad, I ordered a new part and had to manually defrost the refrigerator by turning the timer. To replace the part I had to first unplug the power cord then pull the kick plate off at the front of the refrigerator and remove two screws that hold the timer in place, then pull it out unplug the electric plug in the new timer secure it with the two screws and put the kick plate back in place. I then plugged in the power cord and the refrigerator came on as is now working great..
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Susan from Edgerton, KS
Parts Used:
WP67001255
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Ice maker bucket missing
Needed ice maker bucket for extra fridge. Part came the next day, and worked perfectly.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the TRI18E