TC18C (P7350016W) Amana Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Doug from BRANDON, MS
- Parts Used:
- R0131577
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Fridge would warm above acceptable levels.
Talked to a bud who does this kind of work and he walked me thru the simple job. Also watched a you tube segment. Very easy job. Took off the front kick vent panel. Unscrewed the metal holder and unplugged old part, plugged new part in and put panel back on. Turned on unit and it is working like a charm. Got my fingers crossed just in case.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tom from MINNEAPOLIS, MN
- Parts Used:
- 4318047
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
We would come home from wintering in Texas and the ice maker would again work for about a week. Decided to replace the valve because it wasn't expensive.
Replaced the valve and cleaned all the coils at the same time. The ice maker is spewing out ice. Wife is happy again.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jimmy from LIBERTY, TX
- Parts Used:
- 4318047
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Wrench set
Ice maker wasn't getting water
Removed old water valve on bottom right back side of fridge installed new one which actually took less work
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from North Easton, MA
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Wrench set
Condenser fan making noise
I removed 7 screws hold the heavy cardboard cover on the rear of the fridge. The dificult part was taking the screws that hold the 3 fan motor braces on the fan out. After that it was a matter of making the wire conections and putting it back in. I did not have enough room to laydown to do the work, If i had it would have been a lot easier to see the screws that had to be removed. All in all an easy job, and the part was a perfect fit.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dorothy from Westford, MA
- Parts Used:
- WP67001255
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
I needed a larger ice pan for the freezer.
I took out the old one and put in the new one. For some reason the repair story associated with the ice bucket had nothing to do with ice buckets.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- GREGG from WEST CHESTER, PA
- Parts Used:
- 4318047
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Ice maker was not working.
Ordered new single outlet water valve, received in less than two days. Removed old one, and the repair pretty much feel in place. Instructions were there as a backup. ........ Just curious if the connection from the water source to the valve outlet connection could b a quick connect just the like the water line going directly to the ice maker. Gregg in PA.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Paul from Lowell, MI
- Parts Used:
- 833697
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Socket set
original motor stopped
removed old and instaslled new. biggest problem was getting to one of the screws.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Douglas from Mesa, AZ
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Condenser fan motor froze up
Unplug fridge, unpluged fan motor from plug socket, removed bracket screws, removed fan retainer clip from shaft. removed screws holding fan to bracket
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- William from Milford, MA
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
freezer and food section too warm
removed lower back cover. diconnected fan ass'y electrical connection, removed fan housing (3 screws). removed fan motor from housing. cut old connector from fan and installed on new fan with wire nuts included. re-installed new fan to housing and re-installed housing to frame.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Al from Tonka Bay, MN
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
Condenser Fan Failure
Partition between Freezer and Fridge was running very hot. (Warm is normal). Oiling fan did not work. The only problems encountered in the replacement were getting fan out and in through coolant lines, cut plug off to accomodate generic fan wiring, getting the screws back in without cooking your hand on a hot compressor. Unit works great!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from Belhaven, NC
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
cooling fan quit
Ordered new fan motor on line took out old motor and replaced with new one
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- william from whitwell, TN
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set, Wrench set
fan motor had gone bad
I removed the nuts that held the motor mount, then removed fan blade, cut the wires, and slid the motor pass the mounts and the coil shroud, Installed motor in reverse order. worked out ok.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Santos from Boca Raton, AL
- Parts Used:
- R0131577
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
The fridge started leaking water and stop cooling!
I used the process of elimination. The freezer was cold but the fridge side was warm. The motor was runing but the fan was not working. I unplugged the power cord and pulled everything out of the freezer. Then I took the coil cover out. The unit was frozen solid. I used my wifes hair dryer to melt the ice on the coil and spray water with a bottle to speed up the process. It took about 15 minutes to melt the ice and plug the power cord again. The motor kicked on and the fan started blowing right away so I know it's not the fan. The following morning it was frozen again. I repeated the process of taking everything out and tested the heater element with a multimeter. It wasn't working allowing the ice to build over the coil so I replaced it. It took about 30 minutes to replace but two days later it froze again. I read a little to learn about the timer and the thermostat function in a refrigerator. The timer rotates to turn off the motor and turn on the heater element to melt the ice on the coil. I tried to rotate it but it felt too hard to turn and it smelled burnt out so I replaced it at once. It took me less than 10 minutes to replace. I also learn that the thermostat reaches certain temperature and activates the fan which blows the cold air out of the coil and throughout the fridge compartments. Because the coil and the thermostat were getting covered in ice, it was not activating the fan to blow the air out keeping the freezer side cold and the fridge side warm. By replacing them both, the thermostat and the timer I solved the problem. It took about 30 minutes to replace the thermostat but now it's working like a brand new one again.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Cave Creek, AZ
- Parts Used:
- R0131577
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Evap Fan Stopped Blowing..
My fridge / freezer started getting very warm. But, the compressor and condenser fan were operating. I chose the defrost timer from the parts select suggested list. I took it apart and noticed the contacts were in bad shape. I validated this with my dvm meter. By checking continuity across the contacts while turning the timer knob. I also used my meter to check for 115 vac across the 2, 1 connections. . As you turn the timer knob, you'll hear a click. This should close the contacts and connections 4,3 should power up the evap fan. I also pulled the evap fan and powered it up on my test bench. I did this just to validate the timer was the problem. So, if you have a running compressor and condenser fan. Check the contacts on the defrost timer located under the front grill of your unit with a dvm. There is a small gear motor that runs the timer. Don't be fooled by the fact it's running. If the contacts are toast, replace the timer unit. Total time to fix the problem should be 15 mins. Tops.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gary from Lewisburg, WV
- Parts Used:
- 4318047
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
Solenoid stem had seperated from valve seat.
Turn off water, removed two mounting screws, unplugged solenoid, removed incoming water connection and plastic pipe to ice maker. Installed new valve, connected water lines, reconnected plug, remounted with screws. Turned water back on, over rode power to ice maker and checked for leaks. Total time about 5 minutes. Very easy repair.
Was this instruction helpful to you?
Thank you for voting!