Models > HMG21143-1A > Instructions

HMG21143-1A Admiral Refrigerator - Instructions

Jump to:

All Instructions for the HMG21143-1A
16 - 30 of 137
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Harold from Oakton, VA
Parts Used:
WP61005273
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Wrench set
Single Outlet Water Valve would'nt shut off completely.
Start: UNPLUG THE REFRIGERATOR FROM POWER! Then -

1. Shut off water supply to ice maker.

2. Remove panel from back of refrigerator to expose single outlet water valve.

3. Disconnect water supply line from single outlet water valve.

4. Remove single outlet water valve from refrigerator (one screw).

5. Disconnect water line from the ice maker side of the single outlet water valve.

6. Reconnect the water line from the icemaker side of the old valve to the new single outlet water valve.

7. Re-attach the new single outlet water valve (with water line leading to the ice maker attached) to the refrigerator.

8. Reconnect the water supply line to the single outlet water valve.

9. Turn on the water and check for leaks.

10. Replace panel covering single outlet water valve at back of refrigerator.

Finish: PLUG THE REFRIGERATOR BACK INTO POWER.
15 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dan from Sumner, WA
Parts Used:
WP65889-4
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Fridge stopped working
I called a repair man from a pretty large name to come out and take a look. He found out in about 10 minutes that it was a bad capacitor. The quote he gave me was $75 for the part and $175 labor. I tried my best not to laugh and tell him no thank you. He did have to charge me for him to show up, which was only $98.
So I used what he told(minus the "scrap it") and opened it back up. Although he had left wires everywhere and the broken pieces laying inside, I thought it was enough for me to order the part. PartSelect was very easy to navigate and ordering was a breeze. Took about 4 days to get the part and I ordered in the X-mas craze. Fixed it in about 15 minutes.
10 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Lori from Chuluota, FL
Parts Used:
W11384469
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
There was no light on in refrig area
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one.
But Parts Select is a great place to order from. Thank you.
12 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Rocky River, OH
Parts Used:
WP627985
Difficulty Level:
Difficult
Total Repair Time:
More than 2 hours
Tools:
Pliers, Screw drivers, Socket set
replacing thermostat did not help
Icecubes came out half-way, and refrooze. I figured out, that the melter does not work (HEATER in the icemaker) Voltage measured 105V no load. Studied the Internet, and folloved an advice: shorted the back wire and the blackwire with white stripes.these go to relay contacts. It seems, that the relay contacts are no good on Infrared receiver boaed. I turn off manually the icemaker, when needed
10 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from East Meadow, NY
Parts Used:
W11384469
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
light not working in fridge
It was so easy!

Thanks for the rush to my home on the part.

I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!

Easy!

And I am not Mr. Fix-it!
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Antonio from San Antonio, TX
Parts Used:
W11384469
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.
7 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Duncan from Metairie, LA
Parts Used:
W11384469
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
The Switch Broke...Absolutely Fell Apart.
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Carl from RIVERSIDE, CA
Parts Used:
8009
Difficulty Level:
Very Difficult
Total Repair Time:
More than 2 hours
Tools:
Screw drivers
light bulb in water ice freezer door went bad
I didn't. Don't know how to get to light bulb to change it for this specific model
8 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dave from Manchester Center, VT
Parts Used:
W11384469
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Socket set
Refrigerator light would not stay on
Removed the 2 screws holding the light bulb shield, then the 4 uolding the metal panel. Unplugged the olw door switch and replaced.
reassembled the pieces.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Marlin from WILLIAMSPORT, PA
Parts Used:
WP61005273
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Icemaker water valve leaking, replace same
Watched the video, big help.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dwayne from Gastonia, NC
Parts Used:
WP61004888
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
evaporator fan was noisy
First I unplugged the refrigerator. Next item was the ice-maker; remove (3) screws and unplug it from the back wall. Third task is remove the (4) screws that attach the back wall of the freezer compartment. Lift the wall up enough to dislodge the center cooling shaft that the fan rides in and remove the rear wall. The last item is the fan motor which is attached to the freezer wall by (2) screws and (3) wires which are easily removed. Change out the motor and reassemble freezer compartment .
6 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Warren from Phoenix, AZ
Parts Used:
WP61005273
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
water spilling from the ice maker
The whole job went smoothly,just the way others have described it. Unfortunatlly the water valve was not the problem. The problem was that ice had formed where the water enter's the tray . and therefore could not get into the ice forming area and just spilled into the refrigerator. I removed the ice maker(2 screws and cable connector.) let the ice melt and reconnected all is well again.
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jane from Albuquerque, NM
Parts Used:
W11384469
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers, Socket set
lights wouldn't come on/work in refrigerator
Referencing the info/schematics you have on your website, I unscrewed/unattached top-front panel (carefully), from behind the panel you have to detach the wires (2) from the switch, pushed "in" the switch to remove, put in new switch and attach wires to test BEFORE remounting panel. Tada!! Thank you PartSelect! You saved me at least $80...would have been at least $100 to have a repair person come to the house!
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
riley from CAVE CREEK, AZ
Parts Used:
WP65889-4
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Socket set
Refrig began to trip the GFI circuit in the garage. When plugged into a house interior circuit the lights and fan ran but no cooling in either the freezer or frig.
First of all I want to thank Michael from Carlisle,PA and this site for publishing Michael's info on the wiring specifics on the new 3 connector Start Relay ( WP2262185 ). The original relay only has 2 connectors The 2 orange wires which are combined to one female connector need to be clipped and separated each to its own connector. Refer to Michael's blog as to which wire goes to which connector on the Start Relay. I replaced the Run Capacitor, Start Relay and Overload just to be safe. The Start Relay was the actual culprit.Thank you for an excellent website!
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Lawrence from LAGRANGEVILLE, NY
Parts Used:
WP68601-6, 8009
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Amana thermostat rusted
Add the new one it was slightly different than the original but it worked out perfect.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the HMG21143-1A
16 - 30 of 137