James from Sacramento, CA
Parts Used:
WP61004888
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Temp in the refrig side was too high. Freezer OK
I unpluged the refrig, removed the shelves and the back panel on the freezer side of the unit. This exposed the fan motor and fan blade. I removed two screws holding the fan unit in place, unpluged the wires connecting the fan unit to power, and then removed two other screws securing the fan motor to the bracket. I removed the fan motor blade from the old unit and installed it on the new fam motor. I replaced the fan unit into the bracket, pluged the wires back into the fan motor and secured the motor to the refrig. Replaced the back panel and shelves, pluged the refrig into the wall.....easy.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dora from Rock Island, IL
Parts Used:
W11384469
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
light would come on and off
Viewed the viedo - it showed what to do
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mary Ann from Oostburg, WI
Parts Used:
WP61005273
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
ice maker had always leaked. We were not able to use it.
After several repairmen and still leaking, I did my own diagnosis. I went to Partselect and got the part the NEXT DAY!! Followed directions from video on line and it took less than15 mins.! Now we have more ice than we need! Thanks Partselect!!!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Arlington, MA
Parts Used:
W11384469
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Both light bulbs had been replaced, but lights did not turn on.
I tried to remove the old light switch using a putty knife and a hammer. It was hard to compress the plastic tabs to pull it back through the hole, but all of a sudden, the lights came on. I guess banging on the switch freed-up the contacts. The new switch is now a spare part in case I need it.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dave from Reno, PA
Parts Used:
WP61005273
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Wrench set
Ice Maker Leaking Water In Freezer. And Making Hollow Cubes.
Fairly simple install. Shut off water supply. Removed the old unit. Reversed order and installed the new unit. Turned water back on. Checked for leaks. . . Then put fridg. Back in position. Fixed the problem. . . Makes nice cubes. . .
Was this instruction helpful to you?
Thank you for voting!
Customer:
Donna from Perrysville, OH
Parts Used:
WP61005273
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Socket set, Wrench set
Water Would Not Shop Running Into The Icemaker J Uhh
Cut water line, removed cover,removed old valve and replaced with new one.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from St. Pete Beach, FL
Parts Used:
W11384469
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Broke the arm off the food compartment rocker switch
After receiving the new part almost immediately,using two screw drivers, removed the broken switch from the plastic frame. Be careful not to scratch or otherwise tear the plastic...very pliable. Since the original switch was factory installed and the wires were packed in fiberglass insulation, the switch came out but the wires and clips were still in place and could not reach the new switch. It was necessary to pull them down with bent long nose pliers...used a lot of "pull" but the wires held up.Connected the switch, turned the power on and there was light! Reports from other users really took the uncertainty out of the task.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Don from Laramie, WY
Parts Used:
W11384469
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Switch didn't work
followed the video as instructed. Saved two repairman calls, one to find the problem, one to install. Net savings was about $130.00
Was this instruction helpful to you?
Thank you for voting!
Customer:
Henry from Newland, NC
Parts Used:
WP68601-6
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Refrigerator was running very cold
Unscrewed the right control knob. Removed the left temperature control knob (there is no screw holding it), removed one screw to rear of small panel then pried open from the rear of the small panel, there are two plastic tabs in front of the small panel holding it in place. Unscrewed the failed control unit and replaced it with the new one. Replaced the small panel and screw then the left side control knob, making sure of the alignment in the "off" position as the knob has to be pressured into a clamp arrangement on the cold control thermostat. Re-screwed the right knob into place, as well.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Brian R from Rockwall, TX
Parts Used:
WP61005273
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set, Wrench (Adjustable)
Ice maker water level was overflowing.
I followed the repair instructions the Part Select site provided for this replacement valve. The only differences were I needed a small socket/wrench set in place of screw drivers.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Edward from Sykesville, MD
Parts Used:
WP60106-35
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers, Socket set, Wrench set
Freezer and Refrigerator not cooling properly
Researched this problem on the web. Disassembled the main refrigeration unit (slide out freezer floor panel). The cooling coils were completely iced up. Thawed overnight. Tested the coil thermostat with a multimeter and discovered it worked. Note that the activation temp on this thermostat is 15 degrees Fahrenheit so the ice-water bath test on many web videos will NOT work. My test was in another refrigerator freezer compartment (everyone has two, right?). When the temperature went below 15 and stayed there for 15 minutes, the thermostat opened the circuit. Further investigation revealed that the defrost heater was burnt and shorted. Replaced the defrost heater only to discover that the defrost timer was also broken. After replacing the defrost timer and testing each component thoroughly, the refrigerator is back in service. Freezer maintains about 8 F and the main refrigerator stays at about 36. The unit cycles off properly and the defrost timer is correctly initiating a defrost cycle. Further, when the defrost heater is cycled on, the thermostat correctly shuts it off once the coils are defrosted. Watch the youtube videos. Find your parts and note their specifications so you can test them properly. And good luck.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dustin from Lake Zurich, IL
Parts Used:
WP70048-3
Difficulty Level:
Difficult
Total Repair Time:
1- 2 hours
Tools:
Wrench (Adjustable)
Long time!
Well the repair was not bad the package came in real fast thank you very much. Doing the work was real hard took about an hour to do and then putting it on I do not think it stayed on good still using some duck tape to hold it and the top and bottom are real fat and will not sink on in. I do not know what to do or what I did wrong. I am kind of afraid to take it off because it might rip. Some of it ripped as I was putting it on too. Do you have any ideas of what I can do or what might be my problem? Thanks.

Sincerley,


Dustin Takla