HMG19153-0 Admiral Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Janet from Flagstaff, AZ
- Parts Used:
- W11384469
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
The light went out
I pried the old one out with a screw driver and pushed the new one in. I expected instructions in the box it came in but there were none.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Judith from Phoenix, AZ
- Parts Used:
- 8009
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Bulb Replacement
I pulled down the wire around the glass cover. . . Released on end of the wire from its holder being careful to not let the glass cover drop. Unscrewed the bulb and replaced with replacement. Easy, easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jackie from Nova, OH
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Switch was not working after a repairman had fixed something else
Please bear in mind I am 65 years old & it was harder to get up & down off the floor then to change the switch. Was very easy - watched video, unplugged unit. I used the putty knife at the right front corner to work loose, when it came loose had to loose the left side a little. The unit pulled out easily. detached the wired that had a single plug with 2 prongs on it. Attached the plug, pushed new switch into place. There was no way you could place wires on wrong prong. When done, plugged refrigerator back in & checked if working. I CAN SEE THE LIGHT and the food in the freezer now. Thank you for making an easy repair.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Don from Laramie, WY
- Parts Used:
- W11384469
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
Switch didn't work
followed the video as instructed. Saved two repairman calls, one to find the problem, one to install. Net savings was about $130.00
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Grant from Alexandria, VA
- Parts Used:
- 8009
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Light bulb failure
Received the part the day after ordering. Appreciated the quick service and repair took less than a minute.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Irene from Whitehall, MT
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
No light in frig
We tried repairing with a new switch which was very easy to install but it didn't fix the problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dennis from Lawrenceville, GA
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Light switch which turns on the lights when the door opens went out
This is an easy fix, simply remove and replace. What I was impressed with is that a how to video was provided along with my part. I wish all manufactures would offer this, the video was easy to understand and you had a good view of the operation. Thanks, a job well done.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Anne Marie from St. Johns, FL
- Parts Used:
- WP61005273
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Water not turning on to fill icemaker tray
We were not hearing the water turning on to fill the icemaker tray. Took a chance it was the inlet valve. We were right. Removed old one, found on the lower back side of the frig. Unplugged electric supply, plugged new one in and refastened. In 5 minutes we were hearing the water turn on to fill the tray! Thanks
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joseph T. from Morgantown, WV
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Light switch went bad
Simply stick a putty knife between the switch and refrig wall. Pop out old swith, remove both wires by pulling off switch by terminals. Throw switch out. Put wires on new switch and push into slot and all done. Nothing to it! Took me 5 minutes if th
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from Winhall, VT
- Parts Used:
- WP61005273
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers, Socket set, Wrench (Adjustable)
ice maker stopped making ice
Partselect was great, but I "Gilligan-ed" on the fix changing both the icemaker AND water feed solenoid, BEFORE determining the white rubber water feeder tube that installs from back of fridge and feeds ice maker tray inside of freezer was frozen/ blocked. Make sure you check this FIRST, by proding a screw driver up the tube inside freezer and/ or pulling feeder tube out from back of fridge. If the blockage is substantial enough, it will make removal difficult until melts and tube contracts. Good luck!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from St. Pete Beach, FL
- Parts Used:
- W11384469
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Broke the arm off the food compartment rocker switch
After receiving the new part almost immediately,using two screw drivers, removed the broken switch from the plastic frame. Be careful not to scratch or otherwise tear the plastic...very pliable. Since the original switch was factory installed and the wires were packed in fiberglass insulation, the switch came out but the wires and clips were still in place and could not reach the new switch. It was necessary to pull them down with bent long nose pliers...used a lot of "pull" but the wires held up.Connected the switch, turned the power on and there was light! Reports from other users really took the uncertainty out of the task.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Henry from Newland, NC
- Parts Used:
- WP68601-6
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Refrigerator was running very cold
Unscrewed the right control knob. Removed the left temperature control knob (there is no screw holding it), removed one screw to rear of small panel then pried open from the rear of the small panel, there are two plastic tabs in front of the small panel holding it in place. Unscrewed the failed control unit and replaced it with the new one. Replaced the small panel and screw then the left side control knob, making sure of the alignment in the "off" position as the knob has to be pressured into a clamp arrangement on the cold control thermostat. Re-screwed the right knob into place, as well.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dave from Reno, PA
- Parts Used:
- WP61005273
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Wrench set
Ice Maker Leaking Water In Freezer. And Making Hollow Cubes.
Fairly simple install. Shut off water supply. Removed the old unit. Reversed order and installed the new unit. Turned water back on. Checked for leaks. . . Then put fridg. Back in position. Fixed the problem. . . Makes nice cubes. . .
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Brian R from Rockwall, TX
- Parts Used:
- WP61005273
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set, Wrench (Adjustable)
Ice maker water level was overflowing.
I followed the repair instructions the Part Select site provided for this replacement valve. The only differences were I needed a small socket/wrench set in place of screw drivers.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Sacramento, CA
- Parts Used:
- WP61004888
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Temp in the refrig side was too high. Freezer OK
I unpluged the refrig, removed the shelves and the back panel on the freezer side of the unit. This exposed the fan motor and fan blade. I removed two screws holding the fan unit in place, unpluged the wires connecting the fan unit to power, and then removed two other screws securing the fan motor to the bracket. I removed the fan motor blade from the old unit and installed it on the new fam motor. I replaced the fan unit into the bracket, pluged the wires back into the fan motor and secured the motor to the refrig. Replaced the back panel and shelves, pluged the refrig into the wall.....easy.
Was this instruction helpful to you?
Thank you for voting!