IND2049 4L43A Admiral Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- George from Belhaven, NC
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
cooling fan quit
Ordered new fan motor on line took out old motor and replaced with new one
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kevin from COVINGTON, LA
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Pliers
refrigerator stopped cooling due to condenser over-heating
Pull refrigerator out to access back, unplug unit and remove the 3 .25" screws cut the power leads to motor and install new with easy to understand instructions provided with new motor. Plug refrigerator back in and enjoy your cold beverages once more. EASIEST REPAIR EVER.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Curtis from Sedona, AZ
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Motor noise while running and clicking when shutting off
The instruction sheet supplied with the new motor described the steps to take very good. Replaced the rubber grommets for the three motor mounts also. A flashlight or light source was needed or was very helpful.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Johnnie from Saginaw, MI
- Parts Used:
- WP61001846
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
unit would not freeze
I removed all covers then removed screws from element and disconnected wires and removed it.
when installing the new heater I payed close attention to the routing of thw wires to insure that the terminals were connected properly. I then replaced all covers and turned the frig on and in a couple of hour it was working great again
when installing the new heater I payed close attention to the routing of thw wires to insure that the terminals were connected properly. I then replaced all covers and turned the frig on and in a couple of hour it was working great again
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Howell, MI
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
The door gasket was very hot which is caused by an overheated expansion line that runs along the area of the door gasket. This was caused by a failed cooling fan motor.
Pulled out the refrigerator and removed the two panels from the rear of the refrigerator. Removed the fan held in by four screws and unplugged the connector. Soldered on the original connector, installed the fan to the motor and re-installed the unit into the refrigerator. Then blew out and vaccumed the condenser coils.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jeremy from State College, PA
- Parts Used:
- 833697
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers, Wrench set
Refrigerator would not stay cold
Removed rear cover to see non-operating fan - removed three mounting screws on the motor that were a challenge to access. Swapped fan from old motor onto new motor - one threaded nut on the motor shaft. Spliced new fan wires into fan wires of the wiring harness and mounted with three self-tapping screws supplied with new fan motor. Replaced rear cover and plugged it in! Now the refrigerator cools like new (1981 model side-by-side Admiral)
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Kalamazoo, MI
- Parts Used:
- WP61001846
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Freezer and Frig was not cooling down. The freezer side was all froze up on the coils.
Unplug the Frig and left the freezer side total defrost. Mine was so frozen up, it took about 6 hours with the door open. I had a towel in the botton to catch all the water and ice that fell.
Removed all the shelving units. There are 3 screws that hold the ice maker in place. Loosen the 2 screws above the ice maker about 3 or so turns. Then remove the screw under the ice maker completely. Then lift the ice maker off of the 2 screws that you just loosened. Then with a small flat blade screwdriver, push the plastic clip that holds the connector of wires that plug into the ice maker.
Then remove the screws that hold the back plastic cover that conseals the coil.
Now you should see the coils. There is one heater unit in the middle and one at the botton. There is a screw on each side of the heater unit that you need to take out. They are screwed into a metal bracket that is part of the coil system. Once the screws are removed, you simply remove the heater units. They are plugged in at the top of the coil system on a circuit board. Unplug them from there, (one of the spades connector was slightly bigger then the other, so I new where to plug them back in). Fish all the wire and heater untis out and you are ready to re-oinstall the new units.
Getting the wires back up through the coils was tricky, but I was able to do it.
The hardest thing was working inside the freezer unit. It is not very wide and was sometimes hard to get both hand inside to work.
Removed all the shelving units. There are 3 screws that hold the ice maker in place. Loosen the 2 screws above the ice maker about 3 or so turns. Then remove the screw under the ice maker completely. Then lift the ice maker off of the 2 screws that you just loosened. Then with a small flat blade screwdriver, push the plastic clip that holds the connector of wires that plug into the ice maker.
Then remove the screws that hold the back plastic cover that conseals the coil.
Now you should see the coils. There is one heater unit in the middle and one at the botton. There is a screw on each side of the heater unit that you need to take out. They are screwed into a metal bracket that is part of the coil system. Once the screws are removed, you simply remove the heater units. They are plugged in at the top of the coil system on a circuit board. Unplug them from there, (one of the spades connector was slightly bigger then the other, so I new where to plug them back in). Fish all the wire and heater untis out and you are ready to re-oinstall the new units.
Getting the wires back up through the coils was tricky, but I was able to do it.
The hardest thing was working inside the freezer unit. It is not very wide and was sometimes hard to get both hand inside to work.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- john from irvine, CA
- Parts Used:
- WP61001846
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- More than 2 hours
- Tools:
- Pliers, Screw drivers
refrigator would cool properly
The most difficult part was determining what the problem was, was it the defrost timer, the themostat or the heater. Once I diagnosed the heater the ordering was easy. Installing it took about 30 minutes but waiting for the frig to cool to the point where the thermostat opened took a little longer than I thought. When I saw that orange glow from the heater I knew I saved myself a hundred buck.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- clifford from dayton, OH
- Parts Used:
- WP61001846
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers
small space to work in.
Removed all screws in rear panel & removed (this was easy) . unpluged heater wires & fished out not easy. Used string and 3/8" nut for weight, droped behind evaporator to pull elect wire from heater. ( this was not easy) replaced rear panel & all screws.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from Morgan, UT
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
noisey fan
yup
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas from Augusta, GA
- Parts Used:
- W10887190
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Light Bulb Blew Out In Fridge
Screw bulb in and place cover over bulb.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bruce from Kewadin, MI
- Parts Used:
- 12001414
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
Ice maker did not make ice
This review would not be helpful if limited to this part. So I will describe the whole repair. The ice maker was first receiving too much water. This resulted in huge cubes and water dripping out of the ice maker compartment. I tried reducing the amount of water using the valve to the supply line. But then the ice maker stopped making ice. I jumped to the conclusion that the solenoid water valve needed to be replaced. The new valve was easily replaced, but no water was delivered to the ice maker. I then went to the web site and saw that 87% of the time it was the ice maker itself that needed to be replaced. I ordered one and it arrived quickly. Installing it was easy although I might never had figured out how to remove the electrical supply line to the old unit if I hadn’t watched the video. After installation no water went to the ice maker tray.
I had read a review saying that the supply line had frozen where it went into the ice maker. To check out that possibility I removed the line from the solenoid valve and tried to blow air through it. No air would pass. So I removed the ice maker so I could get at the possible ice obstruction. I repeatedly inserted a knife honing steel which I heated and reheated in hot water. Finally I heard water dripping to the floor from the supply line which I had left detached from the solenoid valve. Then I hooked everything up and ice making proceeded nicely. If the solenoid valve ever needs replacing, I have a extra one.
I had read a review saying that the supply line had frozen where it went into the ice maker. To check out that possibility I removed the line from the solenoid valve and tried to blow air through it. No air would pass. So I removed the ice maker so I could get at the possible ice obstruction. I repeatedly inserted a knife honing steel which I heated and reheated in hot water. Finally I heard water dripping to the floor from the supply line which I had left detached from the solenoid valve. Then I hooked everything up and ice making proceeded nicely. If the solenoid valve ever needs replacing, I have a extra one.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from Hickory, NC
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Condensor Fan going bad
I knew the repair wasn't difficult. It was a matter of finding the replacement part. Luckily, I found the part via the internet on your site. Lucky for me, there was an installation video!! These videos are worth 1000 bucks!! Never have encountered a site with installation videos before. It gave me complete insight as to how the job was sequenced. I'm a very visual person, so videos are the perfect helper for me. With fewer and fewer affordable local service companies around to fix problems like mine, your site gave me the complete confidence to easily switch out the condensor fan. I completed the repair for about $63.00. Your site ROCKS! Keep up the repair videos because they are awesome and extremely helpful. I felt like your pricing was competitive for this item. Thanks again!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- john from thibodaux, LA
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Condensor motor was frozen
pull unit away from the wall, and unplug it. remove the grill, and cardboard guard on the lower back of the unit. remove Three screws for the motor bracket. Remove the bracket legs from the old motor and assemble them to the new motor. take the fan blade off the old motor, place it on the new. Cut the wires at the old motor, strip the insulation back, use supplied wire nuts to connect the new motor. Reverse order to reassemble. Plug in unit to test function.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- michael from woodstock, MD
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Socket set
excessive water in condensate pan
just as video instructions said, very easy just following them ,part arrived in very short time and was exact fit completely satisfied, saved repair man service charges and wait time
Was this instruction helpful to you?
Thank you for voting!