- Customer:
- James from Howell, MI
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
The door gasket was very hot which is caused by an overheated expansion line that runs along the area of the door gasket. This was caused by a failed cooling fan motor.
Pulled out the refrigerator and removed the two panels from the rear of the refrigerator. Removed the fan held in by four screws and unplugged the connector. Soldered on the original connector, installed the fan to the motor and re-installed the unit into the refrigerator. Then blew out and vaccumed the condenser coils.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ivanka from Atlantra, GA
- Parts Used:
- 8009
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
burned oven bulb
The hardest part was taking out original light bulb because screws on shield where hard to unscrew after all this years . The old bulb vent out leaving neck in socket. It took narrow electrical pliers to get neck out .The generic appliance bulb did not fit and had aluminum neck ,not recommended for brass sockets in ovens.Putting new light bulb in was not the problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- William from Schwenksville, PA
- Parts Used:
- 8009
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
oven light burnt out
1. Unscrewed glass cover on bulb
2. Removed old bulb
3. Screwed in new bulb
4. Replaced glass cover
5. Mixed drink & baked cupcakes
2. Removed old bulb
3. Screwed in new bulb
4. Replaced glass cover
5. Mixed drink & baked cupcakes
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Janet from Ada, MI
- Parts Used:
- 8009
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
light bulb went out in my oven
My husband took the plastic cover off and took out old bulb and screwed in the new one. Then put the cover back on.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Shirley from Las Vegas, NV
- Parts Used:
- 8009
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Light burned out in upper oven
Screwed in light bulb and glass protector
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- peggy ann from forest city, NC
- Parts Used:
- 8009
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
replaced oven lightbulb
very easy
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Pamela from Rhinelander, WI
- Parts Used:
- 68139-23
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Glass shelf shattered when I rinsed it off.
I called a local appliance store in town to get a replacement shelf.They did call me back and stated they could not find anything. I found this web site and (had my husband re-measure the size) ordered it on line. I received it in 3 days, and would strongly recommend this web site to anyone.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Judith from Phoenix, AZ
- Parts Used:
- 8009
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Bulb Replacement
I pulled down the wire around the glass cover. . . Released on end of the wire from its holder being careful to not let the glass cover drop. Unscrewed the bulb and replaced with replacement. Easy, easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from Morgan, UT
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
noisey fan
yup
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ken from Eugene, OR
- Parts Used:
- 68139-23
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Glass shelf shattered
Simply inserted the shelf. So easy to find just what we needed from the website. We really got great service and the shelf arrived in three days. Thanks so much.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas from Augusta, GA
- Parts Used:
- W10887190
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Light Bulb Blew Out In Fridge
Screw bulb in and place cover over bulb.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Niles, MI
- Parts Used:
- WP52085-29
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Refrigerator not cooling
Unloading the freezer and removing the back panel were the most time consuming aspect of this repair. Many models only have 4 screws, but this one has 9, and being a side by side it was a tight fit to reach them. Once defrosted we tested the thermostat, found it "dead", and ordered a new one. The part came within 3 business days. Installing it took minutes, since we had not permanently screwed in the back panel again. We didn't want to reload everything until we knew things worked properly, so we didn't put everything back right away. We thought we had further problems as the freezer got really cold but the frig still didn't get down to temp. Turns out we just needed to reinstall the fan shield which we'd taken off along with other parts to access and check the vents. The fan shield must be in place to direct the cold air into the vent to the refrigerator. Duh! It was an oversight that once caught made total sense! Now all works fine on this 20 year old Maytag side by side!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Grant from Alexandria, VA
- Parts Used:
- 8009
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Light bulb failure
Received the part the day after ordering. Appreciated the quick service and repair took less than a minute.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from LAS CRUCES, NM
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
refridgerator was not cooling to the proper temps and finally would not cool at all
Pulled refridgerator forward away from the wall. Remove the cardboard back behind the appliance.I saw that the condenser fan motor was not working. Unplugged the appliance from the electrical outlet. Removed a 3 wire plug from the condenser fan motor. Remove 3 screws (with a nut driver) which held the condenser fan motor in place. Remove the condenser fan motor from the appliance. Looked up the part needed for repair using the appliance model number. Found which part was applicable for the appliance. Placed the order from Price Select on a Monday morning and recieved the part 2 days later on Wednesday via FedEx. The item shipped was a 2 wire condenser fan motor. Read the instructions that came with the part. Using wire cutters, cut the old 3 wire plug. The center wire is a green and yellow striped wire. Use the same colored wire that is also shipped in the box and has connectors on both ends. Cut one of the connectors off and use the wire strippers to remove plastic wire coating. Connect both ends from the appliance and the green and yellow wire that was shipped. Use a wire nut (also shipped in the box) to connect the wires. You will have 2 black wires left on the new condenser fan motor that need to be connected to the appliance. You should have an orange colored wire and another wire that is black with a white stripe. Connect one wire from the new fan motor to the orange wire and use a wire nut to attach both wires together. Use the other black wire from the new fan motor to the black/white striped wire from the appliance. Use the wire nut to attach both those wires. Place the new condenser fan motor back in the appliance using the screws that come with the motor. Attach the green and white wire with the connector on the end to one of the 3 screws that hold the motor in place and secure the screws. Use the electical tape to hold the wires all together and away from the fan motor. Plug the appliance into the outlet. You can see the condenser fan motor working properly. Note that when connecting the 2 black wires from the new condenser fan motor to the orange and the black/white wire from the appliance, for my appliance, it did not matter which wires were connected as the fan motor was a clockwise motor. Place the cardboard appliance backing, back on to the appliance and push the refridgerator back in place. Allow about 5-6 hours to get the freezer to between 0-5 degrees. The refidgerator should be between 34-38 degrees and will take a little longer to get to that projected temp.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from New Albany, IN
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Condensor fan motor quit working
Pulled the fridge out, Took bottom panel off. Removed 3 screws holding motor. Unplugged connector, cut wires, attached old connector on new motor. put blade on new motor.installed in fridge, put cover back on.
Was this instruction helpful to you?
Thank you for voting!