19060A Admiral Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Kevin from COVINGTON, LA
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Pliers
refrigerator stopped cooling due to condenser over-heating
Pull refrigerator out to access back, unplug unit and remove the 3 .25" screws cut the power leads to motor and install new with easy to understand instructions provided with new motor. Plug refrigerator back in and enjoy your cold beverages once more. EASIEST REPAIR EVER.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Johnnie from Saginaw, MI
- Parts Used:
- WP61001846
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
unit would not freeze
I removed all covers then removed screws from element and disconnected wires and removed it.
when installing the new heater I payed close attention to the routing of thw wires to insure that the terminals were connected properly. I then replaced all covers and turned the frig on and in a couple of hour it was working great again
when installing the new heater I payed close attention to the routing of thw wires to insure that the terminals were connected properly. I then replaced all covers and turned the frig on and in a couple of hour it was working great again
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Curtis from Sedona, AZ
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Motor noise while running and clicking when shutting off
The instruction sheet supplied with the new motor described the steps to take very good. Replaced the rubber grommets for the three motor mounts also. A flashlight or light source was needed or was very helpful.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from Belhaven, NC
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
cooling fan quit
Ordered new fan motor on line took out old motor and replaced with new one
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- william from whitwell, TN
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set, Wrench set
fan motor had gone bad
I removed the nuts that held the motor mount, then removed fan blade, cut the wires, and slid the motor pass the mounts and the coil shroud, Installed motor in reverse order. worked out ok.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Kalamazoo, MI
- Parts Used:
- WP61001846
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Freezer and Frig was not cooling down. The freezer side was all froze up on the coils.
Unplug the Frig and left the freezer side total defrost. Mine was so frozen up, it took about 6 hours with the door open. I had a towel in the botton to catch all the water and ice that fell.
Removed all the shelving units. There are 3 screws that hold the ice maker in place. Loosen the 2 screws above the ice maker about 3 or so turns. Then remove the screw under the ice maker completely. Then lift the ice maker off of the 2 screws that you just loosened. Then with a small flat blade screwdriver, push the plastic clip that holds the connector of wires that plug into the ice maker.
Then remove the screws that hold the back plastic cover that conseals the coil.
Now you should see the coils. There is one heater unit in the middle and one at the botton. There is a screw on each side of the heater unit that you need to take out. They are screwed into a metal bracket that is part of the coil system. Once the screws are removed, you simply remove the heater units. They are plugged in at the top of the coil system on a circuit board. Unplug them from there, (one of the spades connector was slightly bigger then the other, so I new where to plug them back in). Fish all the wire and heater untis out and you are ready to re-oinstall the new units.
Getting the wires back up through the coils was tricky, but I was able to do it.
The hardest thing was working inside the freezer unit. It is not very wide and was sometimes hard to get both hand inside to work.
Removed all the shelving units. There are 3 screws that hold the ice maker in place. Loosen the 2 screws above the ice maker about 3 or so turns. Then remove the screw under the ice maker completely. Then lift the ice maker off of the 2 screws that you just loosened. Then with a small flat blade screwdriver, push the plastic clip that holds the connector of wires that plug into the ice maker.
Then remove the screws that hold the back plastic cover that conseals the coil.
Now you should see the coils. There is one heater unit in the middle and one at the botton. There is a screw on each side of the heater unit that you need to take out. They are screwed into a metal bracket that is part of the coil system. Once the screws are removed, you simply remove the heater units. They are plugged in at the top of the coil system on a circuit board. Unplug them from there, (one of the spades connector was slightly bigger then the other, so I new where to plug them back in). Fish all the wire and heater untis out and you are ready to re-oinstall the new units.
Getting the wires back up through the coils was tricky, but I was able to do it.
The hardest thing was working inside the freezer unit. It is not very wide and was sometimes hard to get both hand inside to work.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jeremy from State College, PA
- Parts Used:
- 833697
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers, Wrench set
Refrigerator would not stay cold
Removed rear cover to see non-operating fan - removed three mounting screws on the motor that were a challenge to access. Swapped fan from old motor onto new motor - one threaded nut on the motor shaft. Spliced new fan wires into fan wires of the wiring harness and mounted with three self-tapping screws supplied with new fan motor. Replaced rear cover and plugged it in! Now the refrigerator cools like new (1981 model side-by-side Admiral)
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Howell, MI
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
The door gasket was very hot which is caused by an overheated expansion line that runs along the area of the door gasket. This was caused by a failed cooling fan motor.
Pulled out the refrigerator and removed the two panels from the rear of the refrigerator. Removed the fan held in by four screws and unplugged the connector. Soldered on the original connector, installed the fan to the motor and re-installed the unit into the refrigerator. Then blew out and vaccumed the condenser coils.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- clifford from dayton, OH
- Parts Used:
- WP61001846
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers
small space to work in.
Removed all screws in rear panel & removed (this was easy) . unpluged heater wires & fished out not easy. Used string and 3/8" nut for weight, droped behind evaporator to pull elect wire from heater. ( this was not easy) replaced rear panel & all screws.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- john from irvine, CA
- Parts Used:
- WP61001846
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- More than 2 hours
- Tools:
- Pliers, Screw drivers
refrigator would cool properly
The most difficult part was determining what the problem was, was it the defrost timer, the themostat or the heater. Once I diagnosed the heater the ordering was easy. Installing it took about 30 minutes but waiting for the frig to cool to the point where the thermostat opened took a little longer than I thought. When I saw that orange glow from the heater I knew I saved myself a hundred buck.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from Morgan, UT
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
noisey fan
yup
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Niles, MI
- Parts Used:
- WP52085-29
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Refrigerator not cooling
Unloading the freezer and removing the back panel were the most time consuming aspect of this repair. Many models only have 4 screws, but this one has 9, and being a side by side it was a tight fit to reach them. Once defrosted we tested the thermostat, found it "dead", and ordered a new one. The part came within 3 business days. Installing it took minutes, since we had not permanently screwed in the back panel again. We didn't want to reload everything until we knew things worked properly, so we didn't put everything back right away. We thought we had further problems as the freezer got really cold but the frig still didn't get down to temp. Turns out we just needed to reinstall the fan shield which we'd taken off along with other parts to access and check the vents. The fan shield must be in place to direct the cold air into the vent to the refrigerator. Duh! It was an oversight that once caught made total sense! Now all works fine on this 20 year old Maytag side by side!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from LAS CRUCES, NM
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
refridgerator was not cooling to the proper temps and finally would not cool at all
Pulled refridgerator forward away from the wall. Remove the cardboard back behind the appliance.I saw that the condenser fan motor was not working. Unplugged the appliance from the electrical outlet. Removed a 3 wire plug from the condenser fan motor. Remove 3 screws (with a nut driver) which held the condenser fan motor in place. Remove the condenser fan motor from the appliance. Looked up the part needed for repair using the appliance model number. Found which part was applicable for the appliance. Placed the order from Price Select on a Monday morning and recieved the part 2 days later on Wednesday via FedEx. The item shipped was a 2 wire condenser fan motor. Read the instructions that came with the part. Using wire cutters, cut the old 3 wire plug. The center wire is a green and yellow striped wire. Use the same colored wire that is also shipped in the box and has connectors on both ends. Cut one of the connectors off and use the wire strippers to remove plastic wire coating. Connect both ends from the appliance and the green and yellow wire that was shipped. Use a wire nut (also shipped in the box) to connect the wires. You will have 2 black wires left on the new condenser fan motor that need to be connected to the appliance. You should have an orange colored wire and another wire that is black with a white stripe. Connect one wire from the new fan motor to the orange wire and use a wire nut to attach both wires together. Use the other black wire from the new fan motor to the black/white striped wire from the appliance. Use the wire nut to attach both those wires. Place the new condenser fan motor back in the appliance using the screws that come with the motor. Attach the green and white wire with the connector on the end to one of the 3 screws that hold the motor in place and secure the screws. Use the electical tape to hold the wires all together and away from the fan motor. Plug the appliance into the outlet. You can see the condenser fan motor working properly. Note that when connecting the 2 black wires from the new condenser fan motor to the orange and the black/white wire from the appliance, for my appliance, it did not matter which wires were connected as the fan motor was a clockwise motor. Place the cardboard appliance backing, back on to the appliance and push the refridgerator back in place. Allow about 5-6 hours to get the freezer to between 0-5 degrees. The refidgerator should be between 34-38 degrees and will take a little longer to get to that projected temp.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- michael from woodstock, MD
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Socket set
excessive water in condensate pan
just as video instructions said, very easy just following them ,part arrived in very short time and was exact fit completely satisfied, saved repair man service charges and wait time
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from New Albany, IN
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Condensor fan motor quit working
Pulled the fridge out, Took bottom panel off. Removed 3 screws holding motor. Unplugged connector, cut wires, attached old connector on new motor. put blade on new motor.installed in fridge, put cover back on.
Was this instruction helpful to you?
Thank you for voting!