24902A Admiral Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Joseph from Colonial Heights, VA
- Parts Used:
- WP61003336
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
Drive ring was cracked (power failure & froze-up when power came on)
I read what other people had done so I tried the easiest solution--Forced, without breaking, the plastic & fit the ring right where it needed to be.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from Katy, TX
- Parts Used:
- WP61003336
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Original drive ring broke
The most time-consuming part was removing the screws. First, remove the 8 screws that attaches the ice bin to the front cover. This will free up the auger enough to pull up the back end where the drive ring is held in place. The ring just pops right out. The only thing I recommend is as long as you have the bin out (and empty), go ahead and give it a good wash. Make sure it is thoroughly dry so that no ice freezes to the moving parts.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Pamela from Rhinelander, WI
- Parts Used:
- 68139-23
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Glass shelf shattered when I rinsed it off.
I called a local appliance store in town to get a replacement shelf.They did call me back and stated they could not find anything. I found this web site and (had my husband re-measure the size) ordered it on line. I received it in 3 days, and would strongly recommend this web site to anyone.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Rob from Rome City, IN
- Parts Used:
- WP61003336
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice maker auger wouldn't rotate, motor worked fine
To replace the broken drive coupling on the motor end of the auger requires sliding the ice bin out of the freezer section of the refrigerator. Remove the ice cubes and let it thaw out for a few minutes. Remove five screws holding the front face on the ice bin to remove the ice auger. slip the new drive coupling over the end of the auger. reassemble and replace the face plate with the five screws. Slide the ice bin back in the freezer. Less than fifteen minutes it was finished.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from Morgan, UT
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
noisey fan
yup
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ken from Eugene, OR
- Parts Used:
- 68139-23
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Glass shelf shattered
Simply inserted the shelf. So easy to find just what we needed from the website. We really got great service and the shelf arrived in three days. Thanks so much.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Vickie from Lincoln, NE
- Parts Used:
- W10857122
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
I needed a new grate where the water dispenses.
I just lifed the old grate off and layed the new one in.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Niles, MI
- Parts Used:
- WP52085-29
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Refrigerator not cooling
Unloading the freezer and removing the back panel were the most time consuming aspect of this repair. Many models only have 4 screws, but this one has 9, and being a side by side it was a tight fit to reach them. Once defrosted we tested the thermostat, found it "dead", and ordered a new one. The part came within 3 business days. Installing it took minutes, since we had not permanently screwed in the back panel again. We didn't want to reload everything until we knew things worked properly, so we didn't put everything back right away. We thought we had further problems as the freezer got really cold but the frig still didn't get down to temp. Turns out we just needed to reinstall the fan shield which we'd taken off along with other parts to access and check the vents. The fan shield must be in place to direct the cold air into the vent to the refrigerator. Duh! It was an oversight that once caught made total sense! Now all works fine on this 20 year old Maytag side by side!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bruce from Kewadin, MI
- Parts Used:
- 12001414
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
Ice maker did not make ice
This review would not be helpful if limited to this part. So I will describe the whole repair. The ice maker was first receiving too much water. This resulted in huge cubes and water dripping out of the ice maker compartment. I tried reducing the amount of water using the valve to the supply line. But then the ice maker stopped making ice. I jumped to the conclusion that the solenoid water valve needed to be replaced. The new valve was easily replaced, but no water was delivered to the ice maker. I then went to the web site and saw that 87% of the time it was the ice maker itself that needed to be replaced. I ordered one and it arrived quickly. Installing it was easy although I might never had figured out how to remove the electrical supply line to the old unit if I hadn’t watched the video. After installation no water went to the ice maker tray.
I had read a review saying that the supply line had frozen where it went into the ice maker. To check out that possibility I removed the line from the solenoid valve and tried to blow air through it. No air would pass. So I removed the ice maker so I could get at the possible ice obstruction. I repeatedly inserted a knife honing steel which I heated and reheated in hot water. Finally I heard water dripping to the floor from the supply line which I had left detached from the solenoid valve. Then I hooked everything up and ice making proceeded nicely. If the solenoid valve ever needs replacing, I have a extra one.
I had read a review saying that the supply line had frozen where it went into the ice maker. To check out that possibility I removed the line from the solenoid valve and tried to blow air through it. No air would pass. So I removed the ice maker so I could get at the possible ice obstruction. I repeatedly inserted a knife honing steel which I heated and reheated in hot water. Finally I heard water dripping to the floor from the supply line which I had left detached from the solenoid valve. Then I hooked everything up and ice making proceeded nicely. If the solenoid valve ever needs replacing, I have a extra one.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from Hickory, NC
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Condensor Fan going bad
I knew the repair wasn't difficult. It was a matter of finding the replacement part. Luckily, I found the part via the internet on your site. Lucky for me, there was an installation video!! These videos are worth 1000 bucks!! Never have encountered a site with installation videos before. It gave me complete insight as to how the job was sequenced. I'm a very visual person, so videos are the perfect helper for me. With fewer and fewer affordable local service companies around to fix problems like mine, your site gave me the complete confidence to easily switch out the condensor fan. I completed the repair for about $63.00. Your site ROCKS! Keep up the repair videos because they are awesome and extremely helpful. I felt like your pricing was competitive for this item. Thanks again!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Salem, WI
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Freezer was not getting cold enough
Mine was alittle different than the online instructions. 1. I removed the motor. 2. I took the fan off the old motor and cut the wires about 3" back from old motor. 3. Mounted the new fan on bracket and put the fan on the new motor. 4.connected wires that were cut and used wire nuts to connect. 5. Mounted bracket and motor/fan to unit and it works like its brand new. Thank you PartSelect!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- john from thibodaux, LA
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Condensor motor was frozen
pull unit away from the wall, and unplug it. remove the grill, and cardboard guard on the lower back of the unit. remove Three screws for the motor bracket. Remove the bracket legs from the old motor and assemble them to the new motor. take the fan blade off the old motor, place it on the new. Cut the wires at the old motor, strip the insulation back, use supplied wire nuts to connect the new motor. Reverse order to reassemble. Plug in unit to test function.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jesus from Santa Maria, CA
- Parts Used:
- WP61003336
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
ice bin drive ring was cracked
removed torx screws and replaced ice bin drive ring.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Lincoln, NE
- Parts Used:
- WP61003336
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Broken ice bin drive ring
Easy disassemble removing screws to separate front of ice bin.Be sure to note how metal rod is attached to rear of ice bin. Installed drive ring and reattached face (front) of ice bin in about 15 minutes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Donald from Highland, CA
- Parts Used:
- WP61003336
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice Dispenser drive ring was broken
I pulled the dispenser bin and emptied the existing ice (the maker worked, the dispenser would not dispense). Though there appears to be more, there are about 4 (reciting from memory)very small tap screws holding the front of the dispenser unit to the bin. The dispenser activation screw mounts over protruding items at each end. The item at the back (away from the dispenser gear package) is the drive ring that was broken. The drive ring is a small plastic cup that inserts into an opening at the back of the bin (female side to the rear) and slides into the distal end of the activation screw on the same end. One must line up the small slot on the inside of the drive ring with the end of the screw. Slide the assembly together (make sure that the cube/crush switch rod is properly clipped in place with the return spring hooked to the clip), GENTLY install the 4 or so screws and return he assembly to the freezer. It should work flawlessly. Elapsed time: 15 - 20 minutes.
Was this instruction helpful to you?
Thank you for voting!