Customer:
John from LAS CRUCES, NM
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
refridgerator was not cooling to the proper temps and finally would not cool at all
Pulled refridgerator forward away from the wall. Remove the cardboard back behind the appliance.I saw that the condenser fan motor was not working. Unplugged the appliance from the electrical outlet. Removed a 3 wire plug from the condenser fan motor. Remove 3 screws (with a nut driver) which held the condenser fan motor in place. Remove the condenser fan motor from the appliance. Looked up the part needed for repair using the appliance model number. Found which part was applicable for the appliance. Placed the order from Price Select on a Monday morning and recieved the part 2 days later on Wednesday via FedEx. The item shipped was a 2 wire condenser fan motor. Read the instructions that came with the part. Using wire cutters, cut the old 3 wire plug. The center wire is a green and yellow striped wire. Use the same colored wire that is also shipped in the box and has connectors on both ends. Cut one of the connectors off and use the wire strippers to remove plastic wire coating. Connect both ends from the appliance and the green and yellow wire that was shipped. Use a wire nut (also shipped in the box) to connect the wires. You will have 2 black wires left on the new condenser fan motor that need to be connected to the appliance. You should have an orange colored wire and another wire that is black with a white stripe. Connect one wire from the new fan motor to the orange wire and use a wire nut to attach both wires together. Use the other black wire from the new fan motor to the black/white striped wire from the appliance. Use the wire nut to attach both those wires. Place the new condenser fan motor back in the appliance using the screws that come with the motor. Attach the green and white wire with the connector on the end to one of the 3 screws that hold the motor in place and secure the screws. Use the electical tape to hold the wires all together and away from the fan motor. Plug the appliance into the outlet. You can see the condenser fan motor working properly. Note that when connecting the 2 black wires from the new condenser fan motor to the orange and the black/white wire from the appliance, for my appliance, it did not matter which wires were connected as the fan motor was a clockwise motor. Place the cardboard appliance backing, back on to the appliance and push the refridgerator back in place. Allow about 5-6 hours to get the freezer to between 0-5 degrees. The refidgerator should be between 34-38 degrees and will take a little longer to get to that projected temp.
Was this instruction helpful to you?
Thank you for voting!
Customer:
patrick from livonia, MI
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
condenser motor broke
opened box,read directions,took out bad motor,installed new one.PRESTO CHANGO way to go.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Niles, MI
Parts Used:
WP52085-29
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Refrigerator not cooling
Unloading the freezer and removing the back panel were the most time consuming aspect of this repair. Many models only have 4 screws, but this one has 9, and being a side by side it was a tight fit to reach them. Once defrosted we tested the thermostat, found it "dead", and ordered a new one. The part came within 3 business days. Installing it took minutes, since we had not permanently screwed in the back panel again. We didn't want to reload everything until we knew things worked properly, so we didn't put everything back right away. We thought we had further problems as the freezer got really cold but the frig still didn't get down to temp. Turns out we just needed to reinstall the fan shield which we'd taken off along with other parts to access and check the vents. The fan shield must be in place to direct the cold air into the vent to the refrigerator. Duh! It was an oversight that once caught made total sense! Now all works fine on this 20 year old Maytag side by side!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mary E. from Chicago, IL
Parts Used:
833697
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Socket set
Frozen Lettuce In Crisper
My husband put in in, no problem and all is well. My husband is a mechanic for large machinery/motors so installation was no problem. Thanks, better than buying a new fridge!!!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Cliff from Metairie, LA
Parts Used:
WP10097202
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
compressor will not start - when you turn it on - it hums for a few seconds and them you hear a click sound (the overload opens) and the hum stops
be sure the power cable is NOT plugged into an electrical outlet - removed the cover on the bottom rear of the refrigerator - using a flat blade screw driver pry the cover off the side of the compressor - remove the old relay - remove the wires from the old relay and install them on the new relay in the same location - install the new relay on the compressor connections - snap the cover back on the compressor - replace the cover - power the refrigerator on - the compressor should start and run normally
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from New Albany, IN
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Condensor fan motor quit working
Pulled the fridge out, Took bottom panel off. Removed 3 screws holding motor. Unplugged connector, cut wires, attached old connector on new motor. put blade on new motor.installed in fridge, put cover back on.
Was this instruction helpful to you?
Thank you for voting!
Customer:
George from Hickory, NC
Parts Used:
833697
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Condensor Fan going bad
I knew the repair wasn't difficult. It was a matter of finding the replacement part. Luckily, I found the part via the internet on your site. Lucky for me, there was an installation video!! These videos are worth 1000 bucks!! Never have encountered a site with installation videos before. It gave me complete insight as to how the job was sequenced. I'm a very visual person, so videos are the perfect helper for me. With fewer and fewer affordable local service companies around to fix problems like mine, your site gave me the complete confidence to easily switch out the condensor fan. I completed the repair for about $63.00. Your site ROCKS! Keep up the repair videos because they are awesome and extremely helpful. I felt like your pricing was competitive for this item. Thanks again!!
Was this instruction helpful to you?
Thank you for voting!
Customer:
john from thibodaux, LA
Parts Used:
833697
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Condensor motor was frozen
pull unit away from the wall, and unplug it. remove the grill, and cardboard guard on the lower back of the unit. remove Three screws for the motor bracket. Remove the bracket legs from the old motor and assemble them to the new motor. take the fan blade off the old motor, place it on the new. Cut the wires at the old motor, strip the insulation back, use supplied wire nuts to connect the new motor. Reverse order to reassemble. Plug in unit to test function.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Salem, WI
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Freezer was not getting cold enough
Mine was alittle different than the online instructions. 1. I removed the motor. 2. I took the fan off the old motor and cut the wires about 3" back from old motor. 3. Mounted the new fan on bracket and put the fan on the new motor. 4.connected wires that were cut and used wire nuts to connect. 5. Mounted bracket and motor/fan to unit and it works like its brand new. Thank you PartSelect!
Was this instruction helpful to you?
Thank you for voting!
Customer:
michael from woodstock, MD
Parts Used:
833697
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Socket set
excessive water in condensate pan
just as video instructions said, very easy just following them ,part arrived in very short time and was exact fit completely satisfied, saved repair man service charges and wait time
Was this instruction helpful to you?
Thank you for voting!
Customer:
Donald from Strafford, NH
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Socket set
Refrig ran and ran with a lot of hot air coming from the back. Temps in freezer and refrig areas would fluctuate with the unit running almost constantly. Discovered the fan was intermittently running, mostly not.
Removed the old fan; cut the wire and spliced in the new fan and reassembled. A little over one hour. Refrig is working perfectly now with lower settings. It is definitely off much more than on now.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Batavia, OH
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Pliers, Screw drivers
blower motor was going out
just had to remove the fan motor the hard thing is getting down to it
Was this instruction helpful to you?
Thank you for voting!
Customer:
Barbara from Apollo, PA
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Refrigerator not shutting off, liquids freezing in fridge
It wasn't quite as easy to get to the bolts as the video showed. The lay out of the part wasn't exactly like the video either. However, I managed to put the new part in. Unfortunately, it didn't solve the problem. At first the fridge cycled on and off but after 12 hrs it started to freeze liquids again. Since the appliance was 17 years old we opted to just get a new one.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Mc Alester, OK
Parts Used:
WP61001846
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers
Box Side Hot Frezer Working Fine
Pull box out ""unplug box"" empty frezer including storage baskets,place ice maker in off remove ice cube box, do not remove ice maker, useing nut driver loosen side rail screws about 1/4"slide basket rails in or out and pull to center of box should slip off screws, remove light bulb cover & bulb, remove 4 screws holding ice worm drive motor "" hold "" will fall it is atached to a electrial plug un plug and lay aside,unscrew back panle screws 4 left 4 right on back cover, " remove hiden screw at top center of back panel and pull up and pry out at bottom silde out downwerds,remove cross plates one center one bottom these hold defoster bars, unwind wires center defroster bar somewhat difecult bottom one just slide down unplug from panel at top behind where ice cube drive was located, replace new defroster assm reasemble defroster bars into cross bars wind in & plug up new wires behind cooling fins being carefule not to cut or nick wires of bend cooling fins replace screws,wires are 1 small plug 1 large,reinstall back panle top center screw first don't tighten aline side screw holes replace side screws then tighten top screw. Replace drive motor being sure to conect,replace bulb,bulb cover,side railes,bens,ice cube box & put ice maker lever in on poss. Plug box in weight 8 to 10 hours with box set at mfg 's starting settings. Should work like a charm.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Winston from West Orange, NJ
Parts Used:
WP61001846
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Screw drivers
Cooling coils frozen solid preventing cold air from circulating in freezer and refrigerator compartments.
I removed the cover that protects the freezing tubes, they were frozen solid,used my heat gun to melt away the ice, being very careful not to burn any wires. Then I removed the old heating coils,connected the new ones, replaced the cover and I was done. The thing that took the most time was melting the ice, you cant do it in a hurry because you may burn wires
Was this instruction helpful to you?
Thank you for voting!