22774A Admiral Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Lowell from Tonica, IL
- Parts Used:
- 58397-3
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
ice maker was asking for water, but no ice
replaced the wiring harness, it contains a heating element that allows the water to pass through the discharge tube and not freeze up. I installed the ice maker originally so this was fairly easy repair once I knew the wiring set up.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Edwin from Mount Washington, KY
- Parts Used:
- 4318047
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench set
The old ice maker water valve washer in the water inlet port went bad and was leaking. Lasted for 35 years,
The Whirlpool water inlet valve was better design than the original. All I had to do was drill 2 holes to mount it since it didn't mount in the same location as the old one. I liked the push in connection for the water outlet to the ice maker better than the original plastic screw connection.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jimmy from LIBERTY, TX
- Parts Used:
- 4318047
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Wrench set
Ice maker wasn't getting water
Removed old water valve on bottom right back side of fridge installed new one which actually took less work
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Douglas from Mesa, AZ
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Condenser fan motor froze up
Unplug fridge, unpluged fan motor from plug socket, removed bracket screws, removed fan retainer clip from shaft. removed screws holding fan to bracket
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gerald from TANEYTOWN, MD
- Parts Used:
- WP52185-1
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Pantry Drawer Cover keeps falling off, not held in place by End Cap Kit
I removed the 2 crisper drawers and the glass shelf directly above the Pantry Drawer. Removed the Pantry Drawer and Pantry Drawer cover so you have easy access to the Right-Hand End Cap. On the right-hand End Cap, there are 2 screws which hold the End Cap in place, use a 1/4 inch driver to unscrew the screws from the front of the cabinet on the End Cap and half-way in of the cabinet, leave the screws in their holes in the End Cap. Lift gently to get off a small plastic pin, and move the End Cap away from the Cabinet. You don't need to completely pull the End Cap out of the cabinet, it'll move more like a door opening. Place 2 washers on each screw and gently put the End Cap back into place, being careful NOT to jostle too much so the washers don't fall off the screws. You will need to gently lift the End Cap back in to place over the plastic pin. Hand-tighten the screws back into place with the 1/4 in driver. Remount the Pantry Drawer on the sliders. When you go to install the Pantry Drawer Cover, you will need to gently push on one of the pins to get the cover back into place. Put glass and crisper drawers back into place.
Test by gently pulling on the Pantry Drawer. If properly mounted, the pins will extend fully into the Cover and will keep it secure when opening the Pantry Drawer.
Test by gently pulling on the Pantry Drawer. If properly mounted, the pins will extend fully into the Cover and will keep it secure when opening the Pantry Drawer.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- José from Hialeah, FL
- Parts Used:
- 61001451
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
The drawer had cracked from use
Took out the old drawer and slid the new one
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Don from Frankfort, KY
- Parts Used:
- W11117769
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Renters removed leveling legs from refrigerator. I don't know why!
I tilted the unit back enough to scew the new legs into the threaded holes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Martin from SAN ANTONIO, TX
- Parts Used:
- WP65889-4
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
My amana side to side freezer stoped freezing i found parts select and helped my get a part that by % would be the problemand it worked thanks
I replaced the run capacitor wich is located near the compressor, i first turned power off to fridge than remuved capacitor checked for continuity and the capacitor was the problem thanks
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jack D from CLEBURNE, TX
- Parts Used:
- WP61001846
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Refrigerator and freezer not cooling as required, compressor running continually
Turned refrigerator and freezer controls to off, removed icemaker bin, unplugged icemaker plug and removed two screws holding icemaker in place and removed icemaker. removed screws holding auger motor and freezer compartment light plate, unplugged and set aside. Remover screws holding freezer coil cover in place and removed cover. Allowed coils to defrost completely and then removed screws that hold the two defrost heater coil mounting plates in place, unplugged the two wires that connect the defrost heater coils to the connector block that is located above the freezer coil. Remove the entire defrost heater by working the connecting wires out from along side the freezer coil. Remove the clips that hold the old defrost heater elements to the mounting plates. Install new heating elements into the two mounting plates with the clips. Reinstall the two mounting plates to brackets on freezer coil and reinstall connecting wiring up to connector block and reconnect them. Reinstall freezer coil cover, icemaker auger motor and freezer compartment light plate, and icemaker and bin to complete job. Due to the confined space in the freezer compartment, reinstalling the freezer coil cover and light plate was difficult as I could only use one arm at a time resulting in many dropped screws.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Webbers Falls, OK
- Parts Used:
- WP65889-4
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
Location of the run capacitor was not as the video described.
It was easy after it was apparent that the run capacitor was plugged into the compressor. This was determined from a parts diagram of the actual model refrigerator. The part was the same but the location on the video was wrong. A large screwdriver was used to unplug the capacitor from the compressor. The temperature range of the refrigerator is still too wide but it's colder.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- RICHARD from SPRINGFIELD, MI
- Parts Used:
- WP61001846
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Defrost Heater
it went good
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- GREGG from WEST CHESTER, PA
- Parts Used:
- 4318047
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Ice maker was not working.
Ordered new single outlet water valve, received in less than two days. Removed old one, and the repair pretty much feel in place. Instructions were there as a backup. ........ Just curious if the connection from the water source to the valve outlet connection could b a quick connect just the like the water line going directly to the ice maker. Gregg in PA.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Paul from Lowell, MI
- Parts Used:
- 833697
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Socket set
original motor stopped
removed old and instaslled new. biggest problem was getting to one of the screws.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Amrat from Pomona, CA
- Parts Used:
- WP61001846
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
defrost light on,not getting cold enough
remove all tray,remove back panel,cut out out old heater adn replace with new heatger,refitted back panel and alll tray.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- William from Milford, MA
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
freezer and food section too warm
removed lower back cover. diconnected fan ass'y electrical connection, removed fan housing (3 screws). removed fan motor from housing. cut old connector from fan and installed on new fan with wire nuts included. re-installed new fan to housing and re-installed housing to frame.
Was this instruction helpful to you?
Thank you for voting!