- Customer:
- John from Holden, MA
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Divider front of fridge hot to touch Condenser fan not working
removed back cover, removed fan motor and replaced with new one. connected new power wires. worked right away
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tonya from Grand Prairie, TX
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
Refrigerator quit cooling and the freezer wasn't freezing anything
Order the part from the Internet on Sunday, it mailed out on Monday and I received it on Tuesday. I unplugged the fan then undone 3 screws that held the fan bracket to the refrigerator pulled it out unscrewed 3 more nuts and replaced the fan on the bracket and I cut the old wire plug off the old fan and with 2 wire nuts put it on my new fan. Replaced the fan and bracket back on the refrigerator plugged it in and it works like a new refrigerator.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from Farmington Hills, MI
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Bad fan motor
Pop off six mounting screws and the ground screw. Remove the fan blade and reattach. Reinstall. Save yourself big bucks.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Karl from Wellesley, MA
- Parts Used:
- 833697
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Fan was noisy - bearing had failed
It's self-explanatory. The procedure is obvious; it's just a little difficult. The only hard part is attaching the mounting brackets to the fan. If you can't tighten the mounting bolts, loosen them and reposition the brackets. You might end up mispositioning them at first, because they are hard to reach.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Eric from VALLONIA, IN
- Parts Used:
- WP2183456
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
Compressor would short cycle after overload tripped
Test original overload with meter to see if voltage drops out when overload trips. It did. Measured amp draw to verify compressor load was with in range, it was. New overload no longer trips during compressor start up.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Greensboro, NC
- Parts Used:
- 833697
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Outer case of freezer was heating up, not making ice (sometimes) turned up thermostat several times (especially freezer)
I got the product very quickly. (thank you) Looked at online instructions that were quite vague. Pulled plug.Removed the holder for the fan motor slid it out to see what I had. Removed the mounting screws (3) and slid the motor an fan blade out. I made a cut between the wires and marked the "top" wire to motor to be sure to spin in right direction. Removing fan blade hold down clamp was NOT explained at all but I noted that the shaft on the motor was threaded, so I used pliars and held the shaft white un-screwing clamp. I cleaned the fan blades with degreaser and scraped edges of opening on holder opening. Make sure to use ALL the NEW parts included with this kit when re-installing. They send them for a reason. When slpicing and connecting wires it is a 50/50 shot if you don't mark before cutting. You can connect and try plugging fridge back for moment and make sure it is blowing OUT. Put everything back together and after turning DOWN the thermostats twice, fridge is back to usual. Ice maker is cranking out ice and outside case is cool to the touch.
Note: This can be a DIRTY job especially with 4 dogs in house. Fir and grease don't mix well
Note: This can be a DIRTY job especially with 4 dogs in house. Fir and grease don't mix well
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Granada Hills, CA
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
refrigerator was overheating, condensor fan dead.
First I removed all the screws from the back cover.
2nd removed fan nut and fan blade
3rd removed fan bracket
4th I traced wire to the condenser and disconnected wires from wire nuts.
Installed existing fan brackets to new motor kit
then reconnected wire nuts to new motor cord
Reinstalled fan nut and blade,
reinstalled cover, plugged it in and BAM .WORKS PERF!
2nd removed fan nut and fan blade
3rd removed fan bracket
4th I traced wire to the condenser and disconnected wires from wire nuts.
Installed existing fan brackets to new motor kit
then reconnected wire nuts to new motor cord
Reinstalled fan nut and blade,
reinstalled cover, plugged it in and BAM .WORKS PERF!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- craig from maple grove, MN
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
noisy fridge, perimeter of door heating up
figured out the condenser fan was kaput. Tried WD, worked for several days then gave out completely. Took off back of fridge and trained small fan on compressor while I ordered new condenser fan. The swap was easy, undid the housing bolts, stripped off the connector, reconnected and voila! works perfect.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Douglas from Mesa, AZ
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Condenser fan motor froze up
Unplug fridge, unpluged fan motor from plug socket, removed bracket screws, removed fan retainer clip from shaft. removed screws holding fan to bracket
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Paul from Lowell, MI
- Parts Used:
- 833697
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Socket set
original motor stopped
removed old and instaslled new. biggest problem was getting to one of the screws.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from North Easton, MA
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Wrench set
Condenser fan making noise
I removed 7 screws hold the heavy cardboard cover on the rear of the fridge. The dificult part was taking the screws that hold the 3 fan motor braces on the fan out. After that it was a matter of making the wire conections and putting it back in. I did not have enough room to laydown to do the work, If i had it would have been a lot easier to see the screws that had to be removed. All in all an easy job, and the part was a perfect fit.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lynette from LOS ANGELES, CA
- Parts Used:
- WP10097204
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Replaced a broken starter relay that was clicking
Our refrigerator was no longer emitting cold air and clicking every 5 minutes in what sounded like a "starter" click and then a few minutes later an ending/"shutoff" click. Nothing else would happen between the clicks and we could still hear the freezer fan running in the freezer.
Frequent clicks meant that the starter relay was broken and that the condenser was not failing to start thus failing to cool.
I found very useful videos showing this process on Youtube but here are instructions:
Unplug the refrigerator and open up the back panel on the bottom. The condenser is a black round metal sphere in the center. To the right is the condenser coil which is a flat coil. Attached on the left side of the condenser is a plastic casing with wires coming out from the bottom, that is the relay housing.
Pull the plastic casing off, it is held by a metal clamp. Underneath the plastic casing is the relay. it is attached to the condenser with a straight long pin.
Pull the relay straight out, away from the condenser. You may use a flathead for leverage but I used some elbow grease and slowly wiggled it out.
Look at the relay. For my Admiral, the relay has a little headpiece that sits on the relay and connects to the pin. Otherwise you will have pulled out the relay piece and there will be wires connecting to terminals on the relay.
Remove the wires connecting to the terminals, noting which wires connect to which terminals. Take a picture on your phone if you need to. You may want to use pliers to maintain the terminal connectors on the wires and it may take some elbow grease.
Once all the wires are disconnected from the old relay, discard the old relay. You will know if it's faulty if you shake it and it sounds like it's full of broken glass. A new relay will not make that sound.
Connect the wire connectors to the new relay in the correct terminals.
Reconnect the new relay to the condenser by pushing it back onto the pin all the way.
Replace the plastic cover with the metal clamp.
Clean the dust off the condenser coils while you have the chance.
Replace the back panel and plug in the refrigerator. You should not hear any more clicking and you should feel the air from the freezer become cooler pretty quickly.
Frequent clicks meant that the starter relay was broken and that the condenser was not failing to start thus failing to cool.
I found very useful videos showing this process on Youtube but here are instructions:
Unplug the refrigerator and open up the back panel on the bottom. The condenser is a black round metal sphere in the center. To the right is the condenser coil which is a flat coil. Attached on the left side of the condenser is a plastic casing with wires coming out from the bottom, that is the relay housing.
Pull the plastic casing off, it is held by a metal clamp. Underneath the plastic casing is the relay. it is attached to the condenser with a straight long pin.
Pull the relay straight out, away from the condenser. You may use a flathead for leverage but I used some elbow grease and slowly wiggled it out.
Look at the relay. For my Admiral, the relay has a little headpiece that sits on the relay and connects to the pin. Otherwise you will have pulled out the relay piece and there will be wires connecting to terminals on the relay.
Remove the wires connecting to the terminals, noting which wires connect to which terminals. Take a picture on your phone if you need to. You may want to use pliers to maintain the terminal connectors on the wires and it may take some elbow grease.
Once all the wires are disconnected from the old relay, discard the old relay. You will know if it's faulty if you shake it and it sounds like it's full of broken glass. A new relay will not make that sound.
Connect the wire connectors to the new relay in the correct terminals.
Reconnect the new relay to the condenser by pushing it back onto the pin all the way.
Replace the plastic cover with the metal clamp.
Clean the dust off the condenser coils while you have the chance.
Replace the back panel and plug in the refrigerator. You should not hear any more clicking and you should feel the air from the freezer become cooler pretty quickly.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- William from Milford, MA
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
freezer and food section too warm
removed lower back cover. diconnected fan ass'y electrical connection, removed fan housing (3 screws). removed fan motor from housing. cut old connector from fan and installed on new fan with wire nuts included. re-installed new fan to housing and re-installed housing to frame.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Curtis from Sedona, AZ
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Motor noise while running and clicking when shutting off
The instruction sheet supplied with the new motor described the steps to take very good. Replaced the rubber grommets for the three motor mounts also. A flashlight or light source was needed or was very helpful.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kevin from COVINGTON, LA
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Pliers
refrigerator stopped cooling due to condenser over-heating
Pull refrigerator out to access back, unplug unit and remove the 3 .25" screws cut the power leads to motor and install new with easy to understand instructions provided with new motor. Plug refrigerator back in and enjoy your cold beverages once more. EASIEST REPAIR EVER.
Was this instruction helpful to you?
Thank you for voting!