Models > HMG511080 > Instructions

HMG511080 Admiral Refrigerator - Instructions

Jump to:

All Instructions for the HMG511080
61 - 75 of 209
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
John from Greensboro, NC
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Outer case of freezer was heating up, not making ice (sometimes) turned up thermostat several times (especially freezer)
I got the product very quickly. (thank you) Looked at online instructions that were quite vague. Pulled plug.Removed the holder for the fan motor slid it out to see what I had. Removed the mounting screws (3) and slid the motor an fan blade out. I made a cut between the wires and marked the "top" wire to motor to be sure to spin in right direction. Removing fan blade hold down clamp was NOT explained at all but I noted that the shaft on the motor was threaded, so I used pliars and held the shaft white un-screwing clamp. I cleaned the fan blades with degreaser and scraped edges of opening on holder opening. Make sure to use ALL the NEW parts included with this kit when re-installing. They send them for a reason. When slpicing and connecting wires it is a 50/50 shot if you don't mark before cutting. You can connect and try plugging fridge back for moment and make sure it is blowing OUT. Put everything back together and after turning DOWN the thermostats twice, fridge is back to usual. Ice maker is cranking out ice and outside case is cool to the touch.

Note: This can be a DIRTY job especially with 4 dogs in house. Fir and grease don't mix well
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Granada Hills, CA
Parts Used:
833697
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
refrigerator was overheating, condensor fan dead.
First I removed all the screws from the back cover.
2nd removed fan nut and fan blade
3rd removed fan bracket
4th I traced wire to the condenser and disconnected wires from wire nuts.
Installed existing fan brackets to new motor kit
then reconnected wire nuts to new motor cord
Reinstalled fan nut and blade,
reinstalled cover, plugged it in and BAM .WORKS PERF!
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Las Vegas, NV
Parts Used:
61003647, 61003174
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Door wouldn't close automatically
Removed refrigerated items in door, (3) screws in top hinge bracket & lifted door off lower bracket. Turned door on side & removed lower hinge brkt. & old hinge pin. Replaced with new parts & reassembled door. Luckily I had some grease to apply to parts before reassembly.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
craig from maple grove, MN
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
noisy fridge, perimeter of door heating up
figured out the condenser fan was kaput. Tried WD, worked for several days then gave out completely. Took off back of fridge and trained small fan on compressor while I ordered new condenser fan. The swap was easy, undid the housing bolts, stripped off the connector, reconnected and voila! works perfect.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Douglas from Mesa, AZ
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Condenser fan motor froze up
Unplug fridge, unpluged fan motor from plug socket, removed bracket screws, removed fan retainer clip from shaft. removed screws holding fan to bracket
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from North Easton, MA
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Wrench set
Condenser fan making noise
I removed 7 screws hold the heavy cardboard cover on the rear of the fridge. The dificult part was taking the screws that hold the 3 fan motor braces on the fan out. After that it was a matter of making the wire conections and putting it back in. I did not have enough room to laydown to do the work, If i had it would have been a lot easier to see the screws that had to be removed. All in all an easy job, and the part was a perfect fit.
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Lynette from LOS ANGELES, CA
Parts Used:
WP10097204
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Replaced a broken starter relay that was clicking
Our refrigerator was no longer emitting cold air and clicking every 5 minutes in what sounded like a "starter" click and then a few minutes later an ending/"shutoff" click. Nothing else would happen between the clicks and we could still hear the freezer fan running in the freezer.

Frequent clicks meant that the starter relay was broken and that the condenser was not failing to start thus failing to cool.

I found very useful videos showing this process on Youtube but here are instructions:

Unplug the refrigerator and open up the back panel on the bottom. The condenser is a black round metal sphere in the center. To the right is the condenser coil which is a flat coil. Attached on the left side of the condenser is a plastic casing with wires coming out from the bottom, that is the relay housing.

Pull the plastic casing off, it is held by a metal clamp. Underneath the plastic casing is the relay. it is attached to the condenser with a straight long pin.

Pull the relay straight out, away from the condenser. You may use a flathead for leverage but I used some elbow grease and slowly wiggled it out.

Look at the relay. For my Admiral, the relay has a little headpiece that sits on the relay and connects to the pin. Otherwise you will have pulled out the relay piece and there will be wires connecting to terminals on the relay.

Remove the wires connecting to the terminals, noting which wires connect to which terminals. Take a picture on your phone if you need to. You may want to use pliers to maintain the terminal connectors on the wires and it may take some elbow grease.

Once all the wires are disconnected from the old relay, discard the old relay. You will know if it's faulty if you shake it and it sounds like it's full of broken glass. A new relay will not make that sound.

Connect the wire connectors to the new relay in the correct terminals.

Reconnect the new relay to the condenser by pushing it back onto the pin all the way.

Replace the plastic cover with the metal clamp.

Clean the dust off the condenser coils while you have the chance.

Replace the back panel and plug in the refrigerator. You should not hear any more clicking and you should feel the air from the freezer become cooler pretty quickly.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Shaun from ALEXANDRIA, VA
Parts Used:
WP61006116
Difficulty Level:
Very Difficult
Total Repair Time:
30 - 60 mins
Cannot contact via instruction given by Parts Select so they can answer question below.
Recently I ordered a defroster element from PartSelect Number PS11743275 Manufacturer Part Number WP61006116 for my Maytag Refrigerator/Freezer Model MSD2354ARW. The part received has two numbers on the bag containing the part #61006198 and WP61006198. It looks similar to the picture but the wire connection has three sockets while the element in my freezer has two. Could I have received an incorrect part?

Where do I go from here?

Thanks,

Shaun English
9318 Brambly Lane
Alexandria, VA 22309
703-229-3317
[email protected]
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Martin from SAN ANTONIO, TX
Parts Used:
WP65889-4
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
My amana side to side freezer stoped freezing i found parts select and helped my get a part that by % would be the problemand it worked thanks
I replaced the run capacitor wich is located near the compressor, i first turned power off to fridge than remuved capacitor checked for continuity and the capacitor was the problem thanks
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Justin from BROOKLYN, NY
Parts Used:
W10920279
Difficulty Level:
Very Difficult
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Fridge won't start
When you plug in the fridge it will begin to make noise, but never get cool. When you open the door it will stop and will not turn back on.

This part is listed as one that can fix the problem, but the installation video does not match my fridge.

I've replaced the capacitor (PS11757023), the compressor start relay (PS11740412), and condenser fan (PS1957416) and none of them have fixed the problem.

I really don't want to throw this fridge out. Please help! [email protected]
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Webbers Falls, OK
Parts Used:
WP65889-4
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Socket set
Location of the run capacitor was not as the video described.
It was easy after it was apparent that the run capacitor was plugged into the compressor. This was determined from a parts diagram of the actual model refrigerator. The part was the same but the location on the video was wrong. A large screwdriver was used to unplug the capacitor from the compressor. The temperature range of the refrigerator is still too wide but it's colder.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Carolee from Spokane Valley, WA
Parts Used:
W11384469
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Light switch broke
Pried out old part with screwdriver. Unplugged. When new part came, just plugged it in and pushed the part into place.
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Cathy from HOPATCONG, NJ
Parts Used:
W11384469
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Light rocker switch broke and refrigerator light couldn't go on.
I just popped out the old switch with a flat head screwdriver. Removed the connections and then installed new switch by reversing steps. Popped in back in and the light went on.
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Paul from Lowell, MI
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Socket set
original motor stopped
removed old and instaslled new. biggest problem was getting to one of the screws.
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William from Milford, MA
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Socket set
freezer and food section too warm
removed lower back cover. diconnected fan ass'y electrical connection, removed fan housing (3 screws). removed fan motor from housing. cut old connector from fan and installed on new fan with wire nuts included. re-installed new fan to housing and re-installed housing to frame.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the HMG511080