Broken Ice Maker Motor From Plastic Ice Tray
Given that the augur motor had broken away from the ice tray, removal of the ice tray was simple. Simply remove one screw and slide the tray up and out. Removal of the motor was simple by squeezing the top and bottom of the wire harness plug located on the back of the freezer compartment wall, although it was by feel. The real problem came with trying to remove the augur from the motor shaft (it has a left hand tread) it is on tight and while trying to remove it – I stripped the threads on the motor shaft and couldn’t get the augur off. That’s when the cussing started. No easy fix for this so in addition to the ice tray, I had to order a new ice bucket auger drive motor kit (which included the augur for the end of the motor shaft). Once all the parts arrived, and I had the motor and solenoid assembled and mounted to the back of the tray, the hardest part was plugging the motor back into the plug on the back of the freezer wall- you’ll be doing this by feel (which is a poor design). One suggestion, take a picture of the wire connections between the motor and solenoid – just to be on the safe side – before taking it all apart.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Chris from Greenville, OH
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers, Socket set
Condenser motor stopped working
Removed bad motor with socket set and pliers then removed the connectors from the old motor and soldered them on the new one. Then installed new motor. Works like new! Problem Solved! Easy fix!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from Pleasaton, CA
- Parts Used:
- WP61003336
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice Bin Drive Ring replacement
Easy repair - Don't over complicate it. 1) Flip up ice bar to stop making new ice. 2) Pull out the complete ice bin/tray. 3) shut freezer door while you work on the ice bin. 4) All you need to do is remove the 4 screws holding the ice bin holding tray to the front of the Ice cutting section in the front. 5) Screw drive can then be pulled forward to remove the old/broken white drive cap. Just replace the White Drive ring, put the drive screw back into the ice bin tray and re-install the 4 screws. 6) When re-inserting the bin, you may have to twist the screw drive slightly to re-align with the motor bracket in the back of the freezer. Suggestion: throw out old ice because if it is wet or slightly melted, when you put it back in the freezer the ice will freeze/clump together into a large ice clump; not cubes. Also dry out the ice bin so there is no water to freeze up or create a new jam when the ice bin now re-freezes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Lincoln, NE
- Parts Used:
- WP61003336
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Broken ice bin drive ring
Easy disassemble removing screws to separate front of ice bin.Be sure to note how metal rod is attached to rear of ice bin. Installed drive ring and reattached face (front) of ice bin in about 15 minutes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Donald from Highland, CA
- Parts Used:
- WP61003336
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice Dispenser drive ring was broken
I pulled the dispenser bin and emptied the existing ice (the maker worked, the dispenser would not dispense). Though there appears to be more, there are about 4 (reciting from memory)very small tap screws holding the front of the dispenser unit to the bin. The dispenser activation screw mounts over protruding items at each end. The item at the back (away from the dispenser gear package) is the drive ring that was broken. The drive ring is a small plastic cup that inserts into an opening at the back of the bin (female side to the rear) and slides into the distal end of the activation screw on the same end. One must line up the small slot on the inside of the drive ring with the end of the screw. Slide the assembly together (make sure that the cube/crush switch rod is properly clipped in place with the return spring hooked to the clip), GENTLY install the 4 or so screws and return he assembly to the freezer. It should work flawlessly. Elapsed time: 15 - 20 minutes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Edward from Sykesville, MD
- Parts Used:
- WP60106-35
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers, Socket set, Wrench set
Freezer and Refrigerator not cooling properly
Researched this problem on the web. Disassembled the main refrigeration unit (slide out freezer floor panel). The cooling coils were completely iced up. Thawed overnight. Tested the coil thermostat with a multimeter and discovered it worked. Note that the activation temp on this thermostat is 15 degrees Fahrenheit so the ice-water bath test on many web videos will NOT work. My test was in another refrigerator freezer compartment (everyone has two, right?). When the temperature went below 15 and stayed there for 15 minutes, the thermostat opened the circuit. Further investigation revealed that the defrost heater was burnt and shorted. Replaced the defrost heater only to discover that the defrost timer was also broken. After replacing the defrost timer and testing each component thoroughly, the refrigerator is back in service. Freezer maintains about 8 F and the main refrigerator stays at about 36. The unit cycles off properly and the defrost timer is correctly initiating a defrost cycle. Further, when the defrost heater is cycled on, the thermostat correctly shuts it off once the coils are defrosted. Watch the youtube videos. Find your parts and note their specifications so you can test them properly. And good luck.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Barbara from Apollo, PA
- Parts Used:
- 833697
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
Refrigerator not shutting off, liquids freezing in fridge
It wasn't quite as easy to get to the bolts as the video showed. The lay out of the part wasn't exactly like the video either. However, I managed to put the new part in. Unfortunately, it didn't solve the problem. At first the fridge cycled on and off but after 12 hrs it started to freeze liquids again. Since the appliance was 17 years old we opted to just get a new one.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Salem, WI
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Freezer was not getting cold enough
Mine was alittle different than the online instructions. 1. I removed the motor. 2. I took the fan off the old motor and cut the wires about 3" back from old motor. 3. Mounted the new fan on bracket and put the fan on the new motor. 4.connected wires that were cut and used wire nuts to connect. 5. Mounted bracket and motor/fan to unit and it works like its brand new. Thank you PartSelect!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bruce from Kewadin, MI
- Parts Used:
- 12001414
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
Ice maker did not make ice
This review would not be helpful if limited to this part. So I will describe the whole repair. The ice maker was first receiving too much water. This resulted in huge cubes and water dripping out of the ice maker compartment. I tried reducing the amount of water using the valve to the supply line. But then the ice maker stopped making ice. I jumped to the conclusion that the solenoid water valve needed to be replaced. The new valve was easily replaced, but no water was delivered to the ice maker. I then went to the web site and saw that 87% of the time it was the ice maker itself that needed to be replaced. I ordered one and it arrived quickly. Installing it was easy although I might never had figured out how to remove the electrical supply line to the old unit if I hadn’t watched the video. After installation no water went to the ice maker tray.
I had read a review saying that the supply line had frozen where it went into the ice maker. To check out that possibility I removed the line from the solenoid valve and tried to blow air through it. No air would pass. So I removed the ice maker so I could get at the possible ice obstruction. I repeatedly inserted a knife honing steel which I heated and reheated in hot water. Finally I heard water dripping to the floor from the supply line which I had left detached from the solenoid valve. Then I hooked everything up and ice making proceeded nicely. If the solenoid valve ever needs replacing, I have a extra one.
I had read a review saying that the supply line had frozen where it went into the ice maker. To check out that possibility I removed the line from the solenoid valve and tried to blow air through it. No air would pass. So I removed the ice maker so I could get at the possible ice obstruction. I repeatedly inserted a knife honing steel which I heated and reheated in hot water. Finally I heard water dripping to the floor from the supply line which I had left detached from the solenoid valve. Then I hooked everything up and ice making proceeded nicely. If the solenoid valve ever needs replacing, I have a extra one.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Sacramento, CA
- Parts Used:
- WP61004888
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Temp in the refrig side was too high. Freezer OK
I unpluged the refrig, removed the shelves and the back panel on the freezer side of the unit. This exposed the fan motor and fan blade. I removed two screws holding the fan unit in place, unpluged the wires connecting the fan unit to power, and then removed two other screws securing the fan motor to the bracket. I removed the fan motor blade from the old unit and installed it on the new fam motor. I replaced the fan unit into the bracket, pluged the wires back into the fan motor and secured the motor to the refrig. Replaced the back panel and shelves, pluged the refrig into the wall.....easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Greenville, SC
- Parts Used:
- 12001773
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Two problems- auger motor and ice bucket rack
Had to replace ice bucket rack because auger motor broke the plastic backing and also the auger motor because shaft was bent on old auger motor. Just followed directions on web site to do repair.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from New Albany, IN
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Condensor fan motor quit working
Pulled the fridge out, Took bottom panel off. Removed 3 screws holding motor. Unplugged connector, cut wires, attached old connector on new motor. put blade on new motor.installed in fridge, put cover back on.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- john from thibodaux, LA
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Condensor motor was frozen
pull unit away from the wall, and unplug it. remove the grill, and cardboard guard on the lower back of the unit. remove Three screws for the motor bracket. Remove the bracket legs from the old motor and assemble them to the new motor. take the fan blade off the old motor, place it on the new. Cut the wires at the old motor, strip the insulation back, use supplied wire nuts to connect the new motor. Reverse order to reassemble. Plug in unit to test function.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- michael from woodstock, MD
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Socket set
excessive water in condensate pan
just as video instructions said, very easy just following them ,part arrived in very short time and was exact fit completely satisfied, saved repair man service charges and wait time
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Andrew from Pinckney, MI
- Parts Used:
- 833697
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Freezer was not Defrosting
I have an Amana freeze and I followed the procedure in the video. Which is very good! However on the Amana Model there two slight differences in the procedure that I felt I needed to do. The first one is, the condenser fan bracket is attached to the Freezer chassis with 4 screws, not three. The removal and installation of the back screw by the fan is a bear. I removed the other three and it allowed me to rotate the fan slightly to get more access to the fourth and did same on installation by just starting the 4th screw and then tightening it later. The second issue was my new fan hit the housing when I spun the fan. When I looked at the old one. It had a phenolic washer, between the fan and motor which spaces the fan out about a washer thickness from the motor. When I tried to remove the old one it broke in four pieces due to age. So, I made my own with a washer that I super glued to the motor housing after carefully centering it on and clearing the motor shaft . Seemed to work with out any more noise or balance issues...Thanks, your delivery was blindly fast and video was great!
Was this instruction helpful to you?
Thank you for voting!