Customer:
Robert from Martin, TN
Parts Used:
WP68233-3
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Refrigerator was not staying cold enough. Coils in freezer not defrosting.
Unplugged the unit. Removed items from the freezer. Remove 2 phillip head screws from the cover over the coils. Defrosted the unit with a blow dryer. Upon completion of defrosting, put everything back together. Removed items and top shelf in refrigerator to gain access to the controls. Removed a 1/4 inch nut head screw and loosened 2 each phillip head screws. Unplug the controls from unit and placed on kitchen counter. Removed 3 each phillip head screws holding the timer in place and unplugged the timer. Installed new timer, connected everything back together and placed everything back into the refrigerator. Plugged the unit back up and it is now cooling and defrosting properly. This whole process took approximately 45 minutes.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Honz from Tucson, AZ
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Socket set
intermittent loud whirring noise
Moved fridge out from wall, unplugged power cord. Laid on floor, removed 6 screws from cover. Removed one threaded bolt to allow assembly to slide out. Removed special nut, and took fan off. Removed 3 motor mounting bolts. Unscrewed 2 wire nuts, and untwisted wires. (option 1, no ground) Vacuumed entire area around motor. Used 3 bolts to mount motor to holder assembly, and special nut to install fan. Stripped wires back about 3/4 inch. Twisted two wires together CW, and installed new wire nuts. Slid motor assembly back into slot,(keep wires away from blades) and used one threaded bolt to secure assembly. Reinstalled cover plate with 6 screws. Plugged power cord in to test air flow (out through cover vents). Moved fridge back into place. The loud whirring noise did not stop for a day; then quiet!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Yelm, WA
Parts Used:
WP68233-3
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Refrigurator warm, would not cool. Freezer working fine.
All you need is a 1/4" nut driver or a 1/4" socket and ratchet. Remove the plastic cover to the freezer fan. remove cover to light fixture, bulb, pop out the light socket and remover 2 wires. Remove Ice maker by removing bottom screw and loosing the top 2 screws then lift up and out the ice maker enough to disconnect wiring harness. Revove 4 screws in back panel and the panel can be moved foward. Remove 2 screws holding the fan to the panel. Lay the fan on top of the cooling coil and remove ice maker electrical plug and the panel can be removed easely. Both the heating coil and thermostate switch are easly excessable.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Arlington, MA
Parts Used:
W11384469
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Both light bulbs had been replaced, but lights did not turn on.
I tried to remove the old light switch using a putty knife and a hammer. It was hard to compress the plastic tabs to pull it back through the hole, but all of a sudden, the lights came on. I guess banging on the switch freed-up the contacts. The new switch is now a spare part in case I need it.