Bruce from Kewadin, MI
Parts Used:
12001414
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Wrench (Adjustable)
Ice maker did not make ice
This review would not be helpful if limited to this part. So I will describe the whole repair. The ice maker was first receiving too much water. This resulted in huge cubes and water dripping out of the ice maker compartment. I tried reducing the amount of water using the valve to the supply line. But then the ice maker stopped making ice. I jumped to the conclusion that the solenoid water valve needed to be replaced. The new valve was easily replaced, but no water was delivered to the ice maker. I then went to the web site and saw that 87% of the time it was the ice maker itself that needed to be replaced. I ordered one and it arrived quickly. Installing it was easy although I might never had figured out how to remove the electrical supply line to the old unit if I hadn’t watched the video. After installation no water went to the ice maker tray.

I had read a review saying that the supply line had frozen where it went into the ice maker. To check out that possibility I removed the line from the solenoid valve and tried to blow air through it. No air would pass. So I removed the ice maker so I could get at the possible ice obstruction. I repeatedly inserted a knife honing steel which I heated and reheated in hot water. Finally I heard water dripping to the floor from the supply line which I had left detached from the solenoid valve. Then I hooked everything up and ice making proceeded nicely. If the solenoid valve ever needs replacing, I have a extra one.
Was this instruction helpful to you?
Thank you for voting!
Customer:
George from Pleasaton, CA
Parts Used:
WP61003336
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice Bin Drive Ring replacement
Easy repair - Don't over complicate it. 1) Flip up ice bar to stop making new ice. 2) Pull out the complete ice bin/tray. 3) shut freezer door while you work on the ice bin. 4) All you need to do is remove the 4 screws holding the ice bin holding tray to the front of the Ice cutting section in the front. 5) Screw drive can then be pulled forward to remove the old/broken white drive cap. Just replace the White Drive ring, put the drive screw back into the ice bin tray and re-install the 4 screws. 6) When re-inserting the bin, you may have to twist the screw drive slightly to re-align with the motor bracket in the back of the freezer. Suggestion: throw out old ice because if it is wet or slightly melted, when you put it back in the freezer the ice will freeze/clump together into a large ice clump; not cubes. Also dry out the ice bin so there is no water to freeze up or create a new jam when the ice bin now re-freezes.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jesus from Santa Maria, CA
Parts Used:
WP61003336
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
ice bin drive ring was cracked
removed torx screws and replaced ice bin drive ring.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Lincoln, NE
Parts Used:
WP61003336
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Broken ice bin drive ring
Easy disassemble removing screws to separate front of ice bin.Be sure to note how metal rod is attached to rear of ice bin. Installed drive ring and reattached face (front) of ice bin in about 15 minutes.
Was this instruction helpful to you?
Thank you for voting!
Customer:
james from indian springs, AL
Parts Used:
WP65889-4
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Refrigerator stopped cooling compressor did not cycle
unplug power! Remove the screws from lower panel on back of refrigerator. Lift wire mount out of back panel. Capacitor is mounted directly to the relay and overload switch located on the left side of the compressor. Remove the spring clip holding the capacitor in place and pull the old capacitor out. Plug in new capacitor and replace spring clip. Use vacuum to remove dust from drip pan and wipe fan blades clean. Replace wire into slot on back panel and replace screws. Remove front coil cover below freezer door. vacuum dust off coils and replace cover. Plug refrigerator in and enjoy cold beverages. Relay and overload kit were not required for this repair.
Was this instruction helpful to you?
Thank you for voting!
Customer:
stephanie from lakeland, FL
Parts Used:
WPW10189190
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
refrigerator was not cooling
my 17 year old son actually repair it ...it took him all about 5 minutes to install the part and put that refrigerator cover back on ...very easy fix and save me a bundle of cash ...thank you very much and I will be doing more business with you
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tom from Paducah, KY
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
The freezer compartment was not cold enough.
I found the condenser fan was not working so I bought a new condenser fan kit and installed it. Fixed!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ross from Chandler, AZ
Parts Used:
WP61003336
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Loud crunching and banging from ice dispenser
Problem caused by ice cubes falling out of ice bin and collecting at rear and interfering with ice dispenser drive. Broke plactic drive ring. Pull down 2 clips at front bottom of ice bin. Pull ice bin out. Dump ice cubes. Remove 8 star drive screws to allow case to move far enough to clear broken drive ring. Replace drive ring. Reinstall and tighten 8 screws. Install ice bin. Correct loose right side ice cube retainer board to prevent cubes from falling out of ice bin.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Chris from Greenville, OH
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers, Socket set
Condenser motor stopped working
Removed bad motor with socket set and pliers then removed the connectors from the old motor and soldered them on the new one. Then installed new motor. Works like new! Problem Solved! Easy fix!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jim from Washington, MI
Parts Used:
12001773
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Broken Ice Maker Motor From Plastic Ice Tray
Given that the augur motor had broken away from the ice tray, removal of the ice tray was simple. Simply remove one screw and slide the tray up and out. Removal of the motor was simple by squeezing the top and bottom of the wire harness plug located on the back of the freezer compartment wall, although it was by feel. The real problem came with trying to remove the augur from the motor shaft (it has a left hand tread) it is on tight and while trying to remove it – I stripped the threads on the motor shaft and couldn’t get the augur off. That’s when the cussing started. No easy fix for this so in addition to the ice tray, I had to order a new ice bucket auger drive motor kit (which included the augur for the end of the motor shaft). Once all the parts arrived, and I had the motor and solenoid assembled and mounted to the back of the tray, the hardest part was plugging the motor back into the plug on the back of the freezer wall- you’ll be doing this by feel (which is a poor design). One suggestion, take a picture of the wire connections between the motor and solenoid – just to be on the safe side – before taking it all apart.
Was this instruction helpful to you?
Thank you for voting!
Customer:
PHILLIP from SUN CITY CENTER, FL
Parts Used:
WP65889-4
Difficulty Level:
Easy
Total Repair Time:
More than 2 hours
Tools:
Nutdriver
Loud, non-rythmic clicking noise shortly after the compressor comes on, continuing for several seconds.
Replaced the "Run Capacitor. The non-rythmic clicking associated with the compressor coming on continues. The problem was obviously not the Run Capacitor". I don't know what to do next. Any suggestion would be appreciated.

Thanks,

Phillip
Was this instruction helpful to you?
Thank you for voting!
Customer:
Donald from Highland, CA
Parts Used:
WP61003336
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice Dispenser drive ring was broken
I pulled the dispenser bin and emptied the existing ice (the maker worked, the dispenser would not dispense). Though there appears to be more, there are about 4 (reciting from memory)very small tap screws holding the front of the dispenser unit to the bin. The dispenser activation screw mounts over protruding items at each end. The item at the back (away from the dispenser gear package) is the drive ring that was broken. The drive ring is a small plastic cup that inserts into an opening at the back of the bin (female side to the rear) and slides into the distal end of the activation screw on the same end. One must line up the small slot on the inside of the drive ring with the end of the screw. Slide the assembly together (make sure that the cube/crush switch rod is properly clipped in place with the return spring hooked to the clip), GENTLY install the 4 or so screws and return he assembly to the freezer. It should work flawlessly. Elapsed time: 15 - 20 minutes.
Was this instruction helpful to you?
Thank you for voting!
Customer:
john from thibodaux, LA
Parts Used:
833697
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Condensor motor was frozen
pull unit away from the wall, and unplug it. remove the grill, and cardboard guard on the lower back of the unit. remove Three screws for the motor bracket. Remove the bracket legs from the old motor and assemble them to the new motor. take the fan blade off the old motor, place it on the new. Cut the wires at the old motor, strip the insulation back, use supplied wire nuts to connect the new motor. Reverse order to reassemble. Plug in unit to test function.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Salem, WI
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Freezer was not getting cold enough
Mine was alittle different than the online instructions. 1. I removed the motor. 2. I took the fan off the old motor and cut the wires about 3" back from old motor. 3. Mounted the new fan on bracket and put the fan on the new motor. 4.connected wires that were cut and used wire nuts to connect. 5. Mounted bracket and motor/fan to unit and it works like its brand new. Thank you PartSelect!
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from New Albany, IN
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Condensor fan motor quit working
Pulled the fridge out, Took bottom panel off. Removed 3 screws holding motor. Unplugged connector, cut wires, attached old connector on new motor. put blade on new motor.installed in fridge, put cover back on.