Models > NS20H8A > Instructions

NS20H8A Admiral Refrigerator - Instructions

Jump to:

All Instructions for the NS20H8A
16 - 30 of 61
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Rick from Livonia, NY
Parts Used:
WP61001846
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Pliers, Screw drivers
Freezer Cold With Ice Forming, Fresh Food Warm...Replacing Heater Elements.
1. Removed food from freezer and unplug refrigerator or shut circuit breaker. 2. Removed freezer shelves 3. Unscrew all screws on inside back wall and removed back wall plate. Run a fan to defrost the coils. 4. Unscrewed 4 heater bracket nuts on front of cooling coils and removed heater elements. Mine were burnt so I knew I had the correct part. 5. Removed the heater wires from back panel. 6. Install new heater elements being careful not to leave oils from hands on glass tubes and connected 2 wires from heating elements to rear panel. Reinstall nuts to hold heater brackets. 7. Plug in and run refrigerator for 2 hours with doors closed. Remove upper rear panel on fresh food side then use a flat head screwdriver to turn red timer screw above refrigerator thermostat clockwise slowly until compressor shuts down. 8. Open freezer and waited a few minutes to watch defrost heater coils glow. If they don't glow you might need a new thermostat for the freezer which is located on rear panel or a new timer. 9. Unplug and reinstall rear panel and shelves. Plug in. It will take 24 to 48hrs. For temperatures to level out. Good luck.
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Barbara H. from South Hill, VA
Parts Used:
WP65889-4
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Screw drivers
The refrigerator stopped running
I was told to order the run capacitor and the technician thought it would repair the refrigerator; but it did not. The appliance technician had to take the run capacitor off and install what he called a "hard start" and the refrigerator is operating right now.
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kimberly from Blue Springs, MO
Parts Used:
12002087
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
dual light socket in fridge shorted out
took old socket out, ordered replacement part, dual socket no longer available. Turn off power to appliance, attach new single light socket, screw light socket and light socket holder back into place. Turned on power and it worked. No instructions included in packet, attached wrong first time, blew fuse, attached socket a different way, and it worked.
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jerry from Cleveland, NC
Parts Used:
WP61001846
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
defrost heater burn out
Frist pulled everything out of freezer put in refridge then took out ice maker box then removed ice maker motor removed back panel took hair drier defrosted the coil then removed bracket screws that hold heaters in place removed bad heater, the hardest part of the job was getting the wirers back around the coils when done just reversed the process.I have a side by side so there was not a whole lot of room to work with. I only weigh 160 lbs it was a tight fit for me. But all in all it went well.
Thanks
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
rolando from round lake beach, IL
Parts Used:
WP61001846
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
ice accumulating on evaporator of freezer.
Removed ice maker bin,removed screws on back panel cover. Pulled out panel cover,thawed accumulated ice, unscrewed bracket holding defrost heater set, unplugged busted defroster, plugged in new defroster set,installed it back, installed back panel cover, ice maker and powered it on.More than a week after installation,I don't see any signs of ice accumulation on back panel cover.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
CHRIS from BAYTOWN, TX
Parts Used:
WP61001846
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
Refrigerator compartment warming up
The can drinks in refrigerator were not as cold as usual. I opened the freezer and touched the back panel and noticed there was a frost buildup. Since I have had this problem before, I knew that the defrost heater must be bad. I removed all the shelves and the tracks. The back panel is held in by 8 small sheet metal screws. I removed the screws and pulled the back panel up and out. The refrigerator is in garage, so I put a fan in front of it and the fan melted the ice off the coils. I disconnected the wires and checked the the heaters (both wired together) with an ohm meter. The meter showed the heaters to be open. (bad). Actually only 1 of the 2 heaters were bad, but I replaced both of them since they are wired together as a set.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Daniel from rochester hils, MI
Parts Used:
12002087
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
lights did not work
pulled out old socket and replaced supposed to be a duel socket but no longer exists
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Yafa (and David) from Bothell, WA
Parts Used:
8009
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Replacing the bulb in the freezer side
Removed the ice brucket,
Removed the light shield by releasing one screw using a nutdriver.
Replacing the bulb and reinstalled the light shield.

Your web site is one of the best and most helpfull service sites I ever used. Just wish that in the future you will ship parts overseas.
5 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bruce from Rock Rapids, IA
Parts Used:
WP61001846
Difficulty Level:
Easy
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Screw drivers
Refrigerator and freezer compartment gradually get warmer, frost buildup on back of freezer compartment.
Remove freezer contents, shelving, baskets, shelf brackets, basket rails. Then, remove the icemaker including the ice basket, the cube freezer and the motor assembly. Remove the back liner of the freezer compartment. Remove and replace the defrost heater assembly, using the old mounting brackets and connecting the wires to the same terminals. Reassemble. Discard excess screws :).
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Cami from Carmel, IN
Parts Used:
WP61001846
Difficulty Level:
A Bit Difficult
Total Repair Time:
More than 2 hours
Tools:
Screw drivers
Freezer-side cold; Fridge-side warm of side-by-side Refridgerator
evaporator coils were frozen solid and air wasn't flowing across them

read all directions first, then consider which steps you'd like to take

in any case...
- check for blockages in the upper and lower air vents that allow air from freezer side to cool the fridge-side
- inspect that the fan in the freezer side is actually turning and not blocked


- if no blockages and air is flowing between the sides...

- unplug the unit
- remove all goods from freezer and fridge
- remove freezer side racks
- remove rear panel on freezer side using philips screwdriver (note that the ice-cube tray motor housing must be freed by removing its screws. it can be pull out a bit to get to a single screw holding the top of the rear panel in place)
- allow the evaporator coils to evaporate all ice off, checking the drain pan under the fridge frequently - accelerate the process using a hair dryer or paint stripper (heat gun)
- disconnect the white wires from the connection block located about 2/3 of the way up the rear wall and check resistance using an ohmeter (see specs on back of fridge on circuit diagram)
- if you get a very high resistance reading, the heater element is likely broken. if so...
-- remove the 2 metal shields located horizontally across the evaporator coils (behind them are the two series-connected defrost heater elements)
-- visually inspect the elements - if they are discolored green or black, remove and inspect more closely (most likely they are blown, just like a light-bulb filament that shows black on the glass)
-- if you see nothing, remove them anyway (since high reading) and check connectors
-- replace them (likely only $30 to $75, depending on type)

- if coils seem ok, or if not suspect, check the defrost thermostat WHILE IT IS STILL IN A WORKING/COLD FREEZER.
- get the defrost thermostat into a coil chamber (other freezer or bucket of ice?) and check resistance using an ohmeter. It must be WELL-BELOW 40F to test it. When it is truly immersed in cold (as it would be in a working freezer), test the resistance. it should be 0-ohms when <<40F and some much higher resistance (>200KOhms) when > 40F.
- if not, replace it

-lastly, if neither the defrost heater elements are bad nor the defrost thermostat is bad, open up the defrost timer
-- the defrost timer is located in the fridge side, likely with the fridge thermostat knobs/controller
-- it is a 5-pin part that cannot be repaired. If all else is checked, most likely the defrost element is never coming on because the timer is not turning it on
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from Stone Mountain, GA
Parts Used:
12002087
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Replaced refrigerator light assbly
replacement was relative easy. The problem came with wire connector that had to be cut, stripped and crimped. The crimping was the dificult part. the connector was a problem to crimp.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Glen from Waterboro, ME
Parts Used:
WP61001846
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Freezer was frosting up - no defrost
Found a tip online that said to check the resistance of the defrost coil, when I had none I knew the coils had burned out. Before pulling the old coil out I tied on some long pieces of string as was suggested, that made things go very quick! The hardest part was reaching to the back of the narrow freezer space, but fortunately I have long arms. So far all is working well, and I have a great deal of satisfaction knowing I did the repair myself!
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Amrat from Pomona, CA
Parts Used:
WP61001846
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
defrost light on,not getting cold enough
remove all tray,remove back panel,cut out out old heater adn replace with new heatger,refitted back panel and alll tray.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Webbers Falls, OK
Parts Used:
WP65889-4
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Socket set
Location of the run capacitor was not as the video described.
It was easy after it was apparent that the run capacitor was plugged into the compressor. This was determined from a parts diagram of the actual model refrigerator. The part was the same but the location on the video was wrong. A large screwdriver was used to unplug the capacitor from the compressor. The temperature range of the refrigerator is still too wide but it's colder.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Martin from SAN ANTONIO, TX
Parts Used:
WP65889-4
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
My amana side to side freezer stoped freezing i found parts select and helped my get a part that by % would be the problemand it worked thanks
I replaced the run capacitor wich is located near the compressor, i first turned power off to fridge than remuved capacitor checked for continuity and the capacitor was the problem thanks
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the NS20H8A