Models > 5A74A > Instructions

5A74A Admiral Refrigerator - Instructions

Jump to:

All Instructions for the 5A74A
121 - 135 of 188
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Burton from Pecatonica, IL
Parts Used:
WPW10662129
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Heard a five second buzzing sound repeated 4 or 5 times per cycle coming from rear lower left compressor side.
Removed the six screws holding the bottom access plate found at the rear of the refrigerator. This gives you easy access to the run capacitor that has a retaining clip. Remove the wire clip and pull out the capacitor (it has two quick disconnect terminals). Reverse the process using the new run capacitor to complete the repair.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Adam from Randolph, ME
Parts Used:
WPW10662129
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
Frig not cooling.
After plugging in the new relay to no avail. I replaced the thermostat. That fixed the problem.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Don from Laramie, WY
Parts Used:
W11384469
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Switch didn't work
followed the video as instructed. Saved two repairman calls, one to find the problem, one to install. Net savings was about $130.00
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tom from Paducah, KY
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
The freezer compartment was not cold enough.
I found the condenser fan was not working so I bought a new condenser fan kit and installed it. Fixed!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Chris from Greenville, OH
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers, Socket set
Condenser motor stopped working
Removed bad motor with socket set and pliers then removed the connectors from the old motor and soldered them on the new one. Then installed new motor. Works like new! Problem Solved! Easy fix!
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Sacramento, CA
Parts Used:
WP61004888
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Temp in the refrig side was too high. Freezer OK
I unpluged the refrig, removed the shelves and the back panel on the freezer side of the unit. This exposed the fan motor and fan blade. I removed two screws holding the fan unit in place, unpluged the wires connecting the fan unit to power, and then removed two other screws securing the fan motor to the bracket. I removed the fan motor blade from the old unit and installed it on the new fam motor. I replaced the fan unit into the bracket, pluged the wires back into the fan motor and secured the motor to the refrig. Replaced the back panel and shelves, pluged the refrig into the wall.....easy.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Paula from Rush, NY
Parts Used:
W11384469
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
light switch sticking
I watched the video and thought "I can do this". Made some notes and then proceeded to remove the old switch and replace with the new one. Thank you.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dennis from Lawrenceville, GA
Parts Used:
W11384469
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Light switch which turns on the lights when the door opens went out
This is an easy fix, simply remove and replace. What I was impressed with is that a how to video was provided along with my part. I wish all manufactures would offer this, the video was easy to understand and you had a good view of the operation. Thanks, a job well done.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Steve from River Edge, NJ
Parts Used:
W11384469
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
exchange of defective light rocker switch
1)pry out the old/defective light rocker switch with a screw driver (flat head) and pull out the cables 2)unplug two connectors at the end of light rocker switch 3) connect new light rocker into two connectors 4)push the wires inside and put back new light rocker switch
Was this instruction helpful to you?
Thank you for voting!
Customer:
Anthony from Fairport, NY
Parts Used:
W11384469
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Light in the refrigerator didn't work
I did exactly as the video showed. I popped out the old switch, disconnected the two terminals, connected the new switch and put it back. The light now works! The refrigerator is over 25 years old and the switch works! What a great website this is. Couldn't of done the job without Partselect's help.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Irene from Whitehall, MT
Parts Used:
W11384469
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
No light in frig
We tried repairing with a new switch which was very easy to install but it didn't fix the problem.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Honz from Tucson, AZ
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Socket set
intermittent loud whirring noise
Moved fridge out from wall, unplugged power cord. Laid on floor, removed 6 screws from cover. Removed one threaded bolt to allow assembly to slide out. Removed special nut, and took fan off. Removed 3 motor mounting bolts. Unscrewed 2 wire nuts, and untwisted wires. (option 1, no ground) Vacuumed entire area around motor. Used 3 bolts to mount motor to holder assembly, and special nut to install fan. Stripped wires back about 3/4 inch. Twisted two wires together CW, and installed new wire nuts. Slid motor assembly back into slot,(keep wires away from blades) and used one threaded bolt to secure assembly. Reinstalled cover plate with 6 screws. Plugged power cord in to test air flow (out through cover vents). Moved fridge back into place. The loud whirring noise did not stop for a day; then quiet!
Was this instruction helpful to you?
Thank you for voting!
Customer:
john from white pine, TN
Parts Used:
833697
Difficulty Level:
Really Easy
Total Repair Time:
More than 2 hours
Tools:
Screw drivers, Socket set
Fan motor stopped working
Well I could what laid on the floor and replaced it but I didn't I emptied refrigerator laid it over change the motor then stood it back up actual work about three hours
Was this instruction helpful to you?
Thank you for voting!
Customer:
larry from indianapolis, IN
Parts Used:
833697
Difficulty Level:
Difficult
Total Repair Time:
More than 2 hours
Tools:
Pliers, Socket set, Wrench set
not cooling
removed condenser fan -located behind refrigerator next to compressor, Not much clearance to work, there are 3 screws to remove from condensing motor,sounds easy but clearance is lacking to remove them ,(takes alot of PATIENCE). Then you have to remove the fan blades to be able to get clearance to remove motor!! I wouldn't reccommend trying this repair unless you are a pro.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Timothy from Granite City, IL
Parts Used:
833697
Difficulty Level:
Difficult
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Wrench set
Not cooling properly/ door divider getting hot.
The video of the repair is a helpful guide, but my refrigerator has the compressor very close to the condenser fan motor. With the compressor comes the copper tubing that is all in the way. I had to carefully bend them now and then to allow me to get my hands in position. The how to is easy, but the working with tools in cramped quarters was difficult. I think my Maytag side by side model makes for this job to be difficult, maybe yours may not be so bad. I took a couple of hours to complete. After the first hour, I covered the bare wires, and plugged the frig back in so it could do some cooling. I placed a small in front on the condenser to blow across it. Had a little break, then finished the job.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 5A74A