Jacqueline from LEXINGTON PK, MD
Parts Used:
WPW10662129
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Pliers
No cold
Like you video
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Adam from GLOVERSVILLE, NY
Parts Used:
WPW10662129
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Plugged it in.
Not so good that was not the problem. Fan is not seized and all the lights work and display is not on but lights up as well. No start once plugged back in after 15 minutes of being unplugged. Nothing same no change.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from WINAMAC, IN
Parts Used:
D7824706Q
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
non stick coating coming off in ice cubes / cubes wouldn't come out of tray
Five minutes with a phillips screw driver and the cube maker was changed. . . In the process, I failed to unplug the unit, and shorted the fill valve in the back. Again, five minutes with a nut driver and it was changed. No need for a PHD or the cost of a service technician for either job.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Cathy from HOPATCONG, NJ
Parts Used:
W11384469
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Light rocker switch broke and refrigerator light couldn't go on.
I just popped out the old switch with a flat head screwdriver. Removed the connections and then installed new switch by reversing steps. Popped in back in and the light went on.
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Barry from FORD CITY, PA
Parts Used:
WPW10662129
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Freezer occasionally had a temperature alarm.Clicking noise also.
Was told capacitor was problem 90% of the time.Capacior was not the problem.Bad start relay.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from SPANISH FORK, UT
Parts Used:
D7824706Q
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Old Icemaker Leaked
Replaced Icemaker
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from NORTH HAVEN, CT
Parts Used:
D7824706Q
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Not all ice cubes were coming out of tray. Water was freezing from maker into cube catcher
Remove bottom screw loosen 2 top screws unplug connector from back of icebox. Lift up and pull forward. Swap front cover full bucket stop bar and wire (plugs in) reinstall 10 minute job
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joseph from MILFORD, CT
Parts Used:
D7824706Q
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
not making ice
the diagnosis was the most difficult step.. and trusting that the one visible nut was the only thing holding it on.. (there are 2 other clips that you need to use a little force on to detach). remove the ice maker (one nut, 2 clips, detach plug).. then remove the 3 screws holding on the 'face' , pry face off, you will see where the 'contact' has burned/melted/worn away. replace unit. 80% of the time, this is the problem (according to my research)
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mary L. from Millsboro,, DE
Parts Used:
WP627843
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Ice maker ejector arm broke into.
Removed old ejector arm and installed new part.
16 of 46 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William from Mashpee, MA
Parts Used:
D7824706Q
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
ice maker quit
Removed the elec connection (after unplugging app) found it easier to remove from appliance. Remove the three screws ( do not temove,....just loosen, the top two) bottom must be removed! Insert the power connection, exchange the tilt up rod, line up the water connection and place back on the two top screws. Tighten and relpace the bottom screw. I found out the hard way.... you cant't see the two top screws . The slots on the ice maker just fit over the screw heads.... it's cold in there!!!

Hopoe this helps..

Cape Cod
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Anson from Algonquin, IL
Parts Used:
D7824706Q
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
No Ice Production
I performed basic troubleshooting to make sure there was power and water. Based on historical research on this particular ice maker, I decided that the best direction was to replace the entire assembly. I found this item on this site, ordered it and received it a few days later. I basically removed the ice pan and a few items in the freezer, removed the three mounting screws with either a flat blade screwdriver or nut driver, pulled the electrical harness out of the back wall of the freezer and transferred it to the new ice maker and then installed the new unit, really that simple. Iwas concerned at first, not seeing any activity in the new ice maker but after 15 minutes or so I heard ice falling into the ice bin. Well worth replacing seeing how simple this job was.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
frank from new city, NY
Parts Used:
70076-1
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice maker dripping
Bought ice maker and new harness. Had to buy harness because of water damage. Took out the three screws that attached the ice maker and removed old leaky ice maker. Detached old harnees. Attaced new harness to new ice maker and put on back on with the three screws. Had ice in about 30 minutes. So easy to do!
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
GEORGE from SAN DIEGO, CA
Parts Used:
D7824706Q
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Leaking ice maker
Arrived soon than expected. Unplugged some wires, removed face plate, 3 screws--install and do reverse.

Easier than I would think---Saved $150- to have someone else do it.

Works fine.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Donald from Livermore, CA
Parts Used:
D7824706Q
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Ice Tray leaked
The video of the installation was the best help I have ever had. Rather that vague written instructions that are usually so poorly written they are of no help, the video showed exactly how to do it. I wish everyone provided videos like this!
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bill from Granite Bay, CA
Parts Used:
D7824706Q
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Leaking water every time ice maker fillls.
Replaced entire ice maker. Turn off water where it comes out of the wall. Loosen two top screws and remove one screw at bottom. Lift unit up and off top screws and swivel out to the right and disconnect power plug from freezer. Warning new unit does not come with: 1. Power Cable 2. Front plastic cover. 3. Wire bail. Install in reverse order Do NOT toss old unit until new one is installed and working. My came with the bottom mounting bracket bent so I just used the old one. When installing old power cable into new unit be sure to put small sensor into clip. It's part of the cable harness assembly.
1 person found this instruction helpful.