Models > PNT22H9Y > Instructions

PNT22H9Y Admiral Refrigerator - Instructions

Jump to:

All Instructions for the PNT22H9Y
91 - 105 of 108
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Jesus from Santa Maria, CA
Parts Used:
WP61003336
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
ice bin drive ring was cracked
removed torx screws and replaced ice bin drive ring.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Greenville, SC
Parts Used:
12001773
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Two problems- auger motor and ice bucket rack
Had to replace ice bucket rack because auger motor broke the plastic backing and also the auger motor because shaft was bent on old auger motor. Just followed directions on web site to do repair.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Donald from Highland, CA
Parts Used:
WP61003336
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice Dispenser drive ring was broken
I pulled the dispenser bin and emptied the existing ice (the maker worked, the dispenser would not dispense). Though there appears to be more, there are about 4 (reciting from memory)very small tap screws holding the front of the dispenser unit to the bin. The dispenser activation screw mounts over protruding items at each end. The item at the back (away from the dispenser gear package) is the drive ring that was broken. The drive ring is a small plastic cup that inserts into an opening at the back of the bin (female side to the rear) and slides into the distal end of the activation screw on the same end. One must line up the small slot on the inside of the drive ring with the end of the screw. Slide the assembly together (make sure that the cube/crush switch rod is properly clipped in place with the return spring hooked to the clip), GENTLY install the 4 or so screws and return he assembly to the freezer. It should work flawlessly. Elapsed time: 15 - 20 minutes.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ross from Chandler, AZ
Parts Used:
WP61003336
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Loud crunching and banging from ice dispenser
Problem caused by ice cubes falling out of ice bin and collecting at rear and interfering with ice dispenser drive. Broke plactic drive ring. Pull down 2 clips at front bottom of ice bin. Pull ice bin out. Dump ice cubes. Remove 8 star drive screws to allow case to move far enough to clear broken drive ring. Replace drive ring. Reinstall and tighten 8 screws. Install ice bin. Correct loose right side ice cube retainer board to prevent cubes from falling out of ice bin.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the PNT22H9Y
91 - 105 of 108