Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Richard from Morgan, UT
Parts Used:
833697
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
noisey fan
yup
0 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from Augusta, GA
Parts Used:
W10887190
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Light Bulb Blew Out In Fridge
Screw bulb in and place cover over bulb.
0 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
james from indian springs, AL
Parts Used:
WP65889-4
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Refrigerator stopped cooling compressor did not cycle
unplug power! Remove the screws from lower panel on back of refrigerator. Lift wire mount out of back panel. Capacitor is mounted directly to the relay and overload switch located on the left side of the compressor. Remove the spring clip holding the capacitor in place and pull the old capacitor out. Plug in new capacitor and replace spring clip. Use vacuum to remove dust from drip pan and wipe fan blades clean. Replace wire into slot on back panel and replace screws. Remove front coil cover below freezer door. vacuum dust off coils and replace cover. Plug refrigerator in and enjoy cold beverages. Relay and overload kit were not required for this repair.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Grant from Alexandria, VA
Parts Used:
8009
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Light bulb failure
Received the part the day after ordering. Appreciated the quick service and repair took less than a minute.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from LAS CRUCES, NM
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
refridgerator was not cooling to the proper temps and finally would not cool at all
Pulled refridgerator forward away from the wall. Remove the cardboard back behind the appliance.I saw that the condenser fan motor was not working. Unplugged the appliance from the electrical outlet. Removed a 3 wire plug from the condenser fan motor. Remove 3 screws (with a nut driver) which held the condenser fan motor in place. Remove the condenser fan motor from the appliance. Looked up the part needed for repair using the appliance model number. Found which part was applicable for the appliance. Placed the order from Price Select on a Monday morning and recieved the part 2 days later on Wednesday via FedEx. The item shipped was a 2 wire condenser fan motor. Read the instructions that came with the part. Using wire cutters, cut the old 3 wire plug. The center wire is a green and yellow striped wire. Use the same colored wire that is also shipped in the box and has connectors on both ends. Cut one of the connectors off and use the wire strippers to remove plastic wire coating. Connect both ends from the appliance and the green and yellow wire that was shipped. Use a wire nut (also shipped in the box) to connect the wires. You will have 2 black wires left on the new condenser fan motor that need to be connected to the appliance. You should have an orange colored wire and another wire that is black with a white stripe. Connect one wire from the new fan motor to the orange wire and use a wire nut to attach both wires together. Use the other black wire from the new fan motor to the black/white striped wire from the appliance. Use the wire nut to attach both those wires. Place the new condenser fan motor back in the appliance using the screws that come with the motor. Attach the green and white wire with the connector on the end to one of the 3 screws that hold the motor in place and secure the screws. Use the electical tape to hold the wires all together and away from the fan motor. Plug the appliance into the outlet. You can see the condenser fan motor working properly. Note that when connecting the 2 black wires from the new condenser fan motor to the orange and the black/white wire from the appliance, for my appliance, it did not matter which wires were connected as the fan motor was a clockwise motor. Place the cardboard appliance backing, back on to the appliance and push the refridgerator back in place. Allow about 5-6 hours to get the freezer to between 0-5 degrees. The refidgerator should be between 34-38 degrees and will take a little longer to get to that projected temp.
Was this instruction helpful to you?
Thank you for voting!
Customer:
patrick from livonia, MI
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
condenser motor broke
opened box,read directions,took out bad motor,installed new one.PRESTO CHANGO way to go.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from New Albany, IN
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Condensor fan motor quit working
Pulled the fridge out, Took bottom panel off. Removed 3 screws holding motor. Unplugged connector, cut wires, attached old connector on new motor. put blade on new motor.installed in fridge, put cover back on.
Was this instruction helpful to you?
Thank you for voting!
Customer:
michael from woodstock, MD
Parts Used:
833697
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Socket set
excessive water in condensate pan
just as video instructions said, very easy just following them ,part arrived in very short time and was exact fit completely satisfied, saved repair man service charges and wait time
Was this instruction helpful to you?
Thank you for voting!
Customer:
john from thibodaux, LA
Parts Used:
833697
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Condensor motor was frozen
pull unit away from the wall, and unplug it. remove the grill, and cardboard guard on the lower back of the unit. remove Three screws for the motor bracket. Remove the bracket legs from the old motor and assemble them to the new motor. take the fan blade off the old motor, place it on the new. Cut the wires at the old motor, strip the insulation back, use supplied wire nuts to connect the new motor. Reverse order to reassemble. Plug in unit to test function.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Salem, WI
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Freezer was not getting cold enough
Mine was alittle different than the online instructions. 1. I removed the motor. 2. I took the fan off the old motor and cut the wires about 3" back from old motor. 3. Mounted the new fan on bracket and put the fan on the new motor. 4.connected wires that were cut and used wire nuts to connect. 5. Mounted bracket and motor/fan to unit and it works like its brand new. Thank you PartSelect!
Was this instruction helpful to you?
Thank you for voting!
Customer:
George from Hickory, NC
Parts Used:
833697
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Condensor Fan going bad
I knew the repair wasn't difficult. It was a matter of finding the replacement part. Luckily, I found the part via the internet on your site. Lucky for me, there was an installation video!! These videos are worth 1000 bucks!! Never have encountered a site with installation videos before. It gave me complete insight as to how the job was sequenced. I'm a very visual person, so videos are the perfect helper for me. With fewer and fewer affordable local service companies around to fix problems like mine, your site gave me the complete confidence to easily switch out the condensor fan. I completed the repair for about $63.00. Your site ROCKS! Keep up the repair videos because they are awesome and extremely helpful. I felt like your pricing was competitive for this item. Thanks again!!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Nancy from Gallatin, TN
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
condenser fan wore out
The kit I recieved was perfect. All parts fit and where a perfect match. I will give you an A+ in handling my order and shocked by speed of your delivery.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Honz from Tucson, AZ
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Socket set
intermittent loud whirring noise
Moved fridge out from wall, unplugged power cord. Laid on floor, removed 6 screws from cover. Removed one threaded bolt to allow assembly to slide out. Removed special nut, and took fan off. Removed 3 motor mounting bolts. Unscrewed 2 wire nuts, and untwisted wires. (option 1, no ground) Vacuumed entire area around motor. Used 3 bolts to mount motor to holder assembly, and special nut to install fan. Stripped wires back about 3/4 inch. Twisted two wires together CW, and installed new wire nuts. Slid motor assembly back into slot,(keep wires away from blades) and used one threaded bolt to secure assembly. Reinstalled cover plate with 6 screws. Plugged power cord in to test air flow (out through cover vents). Moved fridge back into place. The loud whirring noise did not stop for a day; then quiet!
Was this instruction helpful to you?
Thank you for voting!
Customer:
stephanie from lakeland, FL
Parts Used:
WPW10189190
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
refrigerator was not cooling
my 17 year old son actually repair it ...it took him all about 5 minutes to install the part and put that refrigerator cover back on ...very easy fix and save me a bundle of cash ...thank you very much and I will be doing more business with you
Was this instruction helpful to you?
Thank you for voting!
Customer:
PHILLIP from SUN CITY CENTER, FL
Parts Used:
WP65889-4
Difficulty Level:
Easy
Total Repair Time:
More than 2 hours
Tools:
Nutdriver
Loud, non-rythmic clicking noise shortly after the compressor comes on, continuing for several seconds.
Replaced the "Run Capacitor. The non-rythmic clicking associated with the compressor coming on continues. The problem was obviously not the Run Capacitor". I don't know what to do next. Any suggestion would be appreciated.

Thanks,

Phillip
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 7L12A