4L43A Admiral Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- William from Bay City, MI
- Parts Used:
- WP61001846
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers
Defrost heater shorted out.
Unplugged refrig., emptied freezer, removed ice bucket drive, removed back wall of freezer, used blower side of vac to defrost coils, remvoed glass heaters and pulled a chase line thru as I removed old wires. Replaced heaters and chased new wires using chase wires.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Choctaw, OK
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
freezer will not freeze or cool the ice box
I have replaced the circuit board, the condenser fan motor but the unit still will not feeze correctly. The bottom of the unit freezes but just barely cools the rest of the freezer and ice box. Have you got any other advice that might help. This is a side by side unit. What else could be the problem. It seems that the fan is not working correctly or it is stuck in defrost mode. The coils where the fan is seem to be icing up but it will not let the fan work. THanks for your help, David Wilson
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Peter from Herndon, VA
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers, Socket set
Condenser Fan Motor seized up
First I removed the back cover then removed 3 nuts holding the motor. Next I removed the two wires. Next I attached new connectors to the wires and installed the new motor and everything worked perfect!
Service and shipping were fantastic! I would definitely use Partselect again!
Service and shipping were fantastic! I would definitely use Partselect again!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- DON from CHANDLER, AZ
- Parts Used:
- WP61001846
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Not defrosting
Removed existing and installed the new part. The hard part is reaching to the back of freezer as it not very wide and is farily deep. Hard to get to arms in at the same time.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dennis from Palm Ciity, FL
- Parts Used:
- WP61001846
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
freezer and fridg would not cool.
Turn off power. unscrewed and removed the panel in the freezer compartment exposing the defroster(6 screws). pulled off the two defroster wires from their lugs. Removed the two plates (4 screws) holding the two heater elements. unsnapped the two heater elements from the plates. installed new heater elements. attached the plates.attached the two wires to the lugs.done
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ernie from Windsor, CA
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 1- 2 hours
refrigerator not cooling properly
Replaced refrigerator cooling control. No luck. Replaced freezer cooling control. No luck. Coils were icing up. Unplugged frig and allowed coils to defrost. After more poking around, found that condenser fan was not spinning. Touch it and it'd start. That was definitely in need of replacement. Replacement was easy. Refrigerator is now running as it should.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Jones, OK
- Parts Used:
- 12001414
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
No water to Ice Maker
Very easy. Pull out refrig from wall to access the rear, turn off ice water line and Unplug refrig from wall outlet. Take socket and unscrew the one (1) tap holding the unit.
Remove the electric conections, pulling out from unit (there is nothing holding it in place but friction).
Remove the main water tube (have papber towel for water drip, there will be some)
Remove the two water tubes on top of unit (noting which tube goes to which relay)
Reconnect electric connectors to the new unit, reonnect water tubes to the new unit, screw down the new unit.
Turn water on and plug refrig back into AC outlet.
That's it, 20-30 min.
Remove the electric conections, pulling out from unit (there is nothing holding it in place but friction).
Remove the main water tube (have papber towel for water drip, there will be some)
Remove the two water tubes on top of unit (noting which tube goes to which relay)
Reconnect electric connectors to the new unit, reonnect water tubes to the new unit, screw down the new unit.
Turn water on and plug refrig back into AC outlet.
That's it, 20-30 min.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Vernon from Festus, MO
- Parts Used:
- 55440-2
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice Maker would not shut off.
Removed the rubber gasket and checked the switch. The switch displayed signs of scorching and the plastic was very brittle. Removed the switch which was held in by a small bracket and one screw. Replaced switch on bracket and remounted the switch. It took longer to reinstall the rubber gasket that to diagnoise and repair the switch. This was a very easy repair and the time from the part order to receiving it was two days. I'm very pleased with the part availability and quick shipping.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- bobbie from belleville, IL
- Parts Used:
- WP61001846
- Difficulty Level:
- Very Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers
Ice Build Up On Evap Coil
Removing the old heater coil was a bit of a task as you need to take off all the brackets holding the heater coil and then remove the wiring from back of the coil. Installing the new heater coil assembly in the brackets and feeding the wirings back up to the top was a major task. Need to have long arms as the heater is located way back in the freezer compartment. The part was the exact match. The part was delivered in 2 days. Thanks alot. Will use your site again.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kevin from FOUNTAIN HLS, AZ
- Parts Used:
- 55440-2
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers
Water / Ice dispenser would not stop flowing / running
Our 20+ year old Maytag refrigerator suddenly started dispensing water one day without anyone near the refrigerator. Thankfully, my wife was nearby; my son temporarily solved the problem by shutting off water to the house. The ice dispenser unit has a "Lock" switch which turns off power to the ice & water dispenser. With the switch in the "lock" position, we were able to continue using the refrigerator (and turn the water back on) until I was able to get a replacement part.
The biggest hurdle that I encountered was removing the trim; I spent perhaps an hour and a half trying to figure it out. In the end it turned out to be easy and would have been perhaps half an hour job total had I known the trick. So... to remove the trim on a Maytag RSW2400, you remove a single Phillips head screw on the bottom of the trim. The trim then slides to the left and can be removed.
The next mistake I made was removing the entire dispenser unit. Instead, if you look closely, there are screws which may be used to disassemble part of it, leaving the ice/water dispenser housing mounted to the refrigerator door. This provides access to the ice/water actuator switch. Perform this disassembly and access to the switch becomes obvious.
The switch is held in place with a single Phillips screw. Make sure that you've disconnected the power to the fridge well before this point because, AFAICT, 120VAC flows through this switch! The switch that I replaced didn't appear to be in bad shape and, once removed, the switch seemed to work correctly when I tested it with an ohmmeter. I replaced it anyway.
Reassembly was straightforward and easy. Better still, ice and water are now dispensed correctly again.
The biggest hurdle that I encountered was removing the trim; I spent perhaps an hour and a half trying to figure it out. In the end it turned out to be easy and would have been perhaps half an hour job total had I known the trick. So... to remove the trim on a Maytag RSW2400, you remove a single Phillips head screw on the bottom of the trim. The trim then slides to the left and can be removed.
The next mistake I made was removing the entire dispenser unit. Instead, if you look closely, there are screws which may be used to disassemble part of it, leaving the ice/water dispenser housing mounted to the refrigerator door. This provides access to the ice/water actuator switch. Perform this disassembly and access to the switch becomes obvious.
The switch is held in place with a single Phillips screw. Make sure that you've disconnected the power to the fridge well before this point because, AFAICT, 120VAC flows through this switch! The switch that I replaced didn't appear to be in bad shape and, once removed, the switch seemed to work correctly when I tested it with an ohmmeter. I replaced it anyway.
Reassembly was straightforward and easy. Better still, ice and water are now dispensed correctly again.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Holden, MA
- Parts Used:
- 833697
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Divider front of fridge hot to touch Condenser fan not working
removed back cover, removed fan motor and replaced with new one. connected new power wires. worked right away
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kimberly from Blue Springs, MO
- Parts Used:
- 12002087
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
dual light socket in fridge shorted out
took old socket out, ordered replacement part, dual socket no longer available. Turn off power to appliance, attach new single light socket, screw light socket and light socket holder back into place. Turned on power and it worked. No instructions included in packet, attached wrong first time, blew fuse, attached socket a different way, and it worked.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- stephen from montgomery, NY
- Parts Used:
- W11117769
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Wrench (Adjustable)
No leveling legs
Ordered the leveling bolts, very fast shipping, parts correct as shown. Purchased a condo by the shore, frige had no levelers, they went in smoothly & was done in no time.
Steve
Steve
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Rick from Livonia, NY
- Parts Used:
- WP61001846
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers, Screw drivers
Freezer Cold With Ice Forming, Fresh Food Warm...Replacing Heater Elements.
1. Removed food from freezer and unplug refrigerator or shut circuit breaker. 2. Removed freezer shelves 3. Unscrew all screws on inside back wall and removed back wall plate. Run a fan to defrost the coils. 4. Unscrewed 4 heater bracket nuts on front of cooling coils and removed heater elements. Mine were burnt so I knew I had the correct part. 5. Removed the heater wires from back panel. 6. Install new heater elements being careful not to leave oils from hands on glass tubes and connected 2 wires from heating elements to rear panel. Reinstall nuts to hold heater brackets. 7. Plug in and run refrigerator for 2 hours with doors closed. Remove upper rear panel on fresh food side then use a flat head screwdriver to turn red timer screw above refrigerator thermostat clockwise slowly until compressor shuts down. 8. Open freezer and waited a few minutes to watch defrost heater coils glow. If they don't glow you might need a new thermostat for the freezer which is located on rear panel or a new timer. 9. Unplug and reinstall rear panel and shelves. Plug in. It will take 24 to 48hrs. For temperatures to level out. Good luck.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tonya from Grand Prairie, TX
- Parts Used:
- 833697
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
Refrigerator quit cooling and the freezer wasn't freezing anything
Order the part from the Internet on Sunday, it mailed out on Monday and I received it on Tuesday. I unplugged the fan then undone 3 screws that held the fan bracket to the refrigerator pulled it out unscrewed 3 more nuts and replaced the fan on the bracket and I cut the old wire plug off the old fan and with 2 wire nuts put it on my new fan. Replaced the fan and bracket back on the refrigerator plugged it in and it works like a new refrigerator.
Was this instruction helpful to you?
Thank you for voting!