Customer:
Jack D from CLEBURNE, TX
Parts Used:
WP61001846
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
Refrigerator and freezer not cooling as required, compressor running continually
Turned refrigerator and freezer controls to off, removed icemaker bin, unplugged icemaker plug and removed two screws holding icemaker in place and removed icemaker. removed screws holding auger motor and freezer compartment light plate, unplugged and set aside. Remover screws holding freezer coil cover in place and removed cover. Allowed coils to defrost completely and then removed screws that hold the two defrost heater coil mounting plates in place, unplugged the two wires that connect the defrost heater coils to the connector block that is located above the freezer coil. Remove the entire defrost heater by working the connecting wires out from along side the freezer coil. Remove the clips that hold the old defrost heater elements to the mounting plates. Install new heating elements into the two mounting plates with the clips. Reinstall the two mounting plates to brackets on freezer coil and reinstall connecting wiring up to connector block and reconnect them. Reinstall freezer coil cover, icemaker auger motor and freezer compartment light plate, and icemaker and bin to complete job. Due to the confined space in the freezer compartment, reinstalling the freezer coil cover and light plate was difficult as I could only use one arm at a time resulting in many dropped screws.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
RICHARD from SPRINGFIELD, MI
Parts Used:
WP61001846
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Defrost Heater
it went good
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William from Milford, MA
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Socket set
freezer and food section too warm
removed lower back cover. diconnected fan ass'y electrical connection, removed fan housing (3 screws). removed fan motor from housing. cut old connector from fan and installed on new fan with wire nuts included. re-installed new fan to housing and re-installed housing to frame.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
George from Belhaven, NC
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
cooling fan quit
Ordered new fan motor on line took out old motor and replaced with new one
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
william from whitwell, TN
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Socket set, Wrench set
fan motor had gone bad
I removed the nuts that held the motor mount, then removed fan blade, cut the wires, and slid the motor pass the mounts and the coil shroud, Installed motor in reverse order. worked out ok.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gary from Lewisburg, WV
Parts Used:
4318047
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Wrench (Adjustable)
Solenoid stem had seperated from valve seat.
Turn off water, removed two mounting screws, unplugged solenoid, removed incoming water connection and plastic pipe to ice maker. Installed new valve, connected water lines, reconnected plug, remounted with screws. Turned water back on, over rode power to ice maker and checked for leaks. Total time about 5 minutes. Very easy repair.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kevin from COVINGTON, LA
Parts Used:
833697
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Pliers
refrigerator stopped cooling due to condenser over-heating
Pull refrigerator out to access back, unplug unit and remove the 3 .25" screws cut the power leads to motor and install new with easy to understand instructions provided with new motor. Plug refrigerator back in and enjoy your cold beverages once more. EASIEST REPAIR EVER.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Edward from Claymont, DE
Parts Used:
WP59688-1A
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
the ice was sticking to the tray and would fill each time it cycled the flood the dispencer
replaced the ice cube tray
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Johnnie from Saginaw, MI
Parts Used:
WP61001846
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
unit would not freeze
I removed all covers then removed screws from element and disconnected wires and removed it.
when installing the new heater I payed close attention to the routing of thw wires to insure that the terminals were connected properly. I then replaced all covers and turned the frig on and in a couple of hour it was working great again
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Al from Tonka Bay, MN
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Socket set
Condenser Fan Failure
Partition between Freezer and Fridge was running very hot. (Warm is normal). Oiling fan did not work. The only problems encountered in the replacement were getting fan out and in through coolant lines, cut plug off to accomodate generic fan wiring, getting the screws back in without cooking your hand on a hot compressor. Unit works great!
2 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Curtis from Sedona, AZ
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Motor noise while running and clicking when shutting off
The instruction sheet supplied with the new motor described the steps to take very good. Replaced the rubber grommets for the three motor mounts also. A flashlight or light source was needed or was very helpful.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jeremy from State College, PA
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers, Wrench set
Refrigerator would not stay cold
Removed rear cover to see non-operating fan - removed three mounting screws on the motor that were a challenge to access. Swapped fan from old motor onto new motor - one threaded nut on the motor shaft. Spliced new fan wires into fan wires of the wiring harness and mounted with three self-tapping screws supplied with new fan motor. Replaced rear cover and plugged it in! Now the refrigerator cools like new (1981 model side-by-side Admiral)
2 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Steven from Atlanta, GA
Parts Used:
4318047
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Wrench set
The Ice was hollow and then it just t stopped.
The first issue was to determine if the problem was with the ice maker or the water dispenser / pump. I chose to try to repair the dispenser first since there air bubbles in the plastic line. Also, the ice maker seems to have been working. There just wasn't enough water so the ice cubes were hollow.

I unplugged the power cord, , removed the cardboard backing and two bolts that secured the pump to the refrigerator. I vacumned the area so I could see around. I pulled the valve out and disconnected it from the internal power source. I disconnected the copper water intake and the plastic tubbing to the ice maker. I used a pipe cutter to take the old flanged area off. A new flange was included in the package. I used that and reconnected the copper intake and the plastic tubbing. I replaced the power source and secured the valve to the refrigerator makeing sure the plastic tubbing wasn't twisted. When I plugged the refrigator back up, the ice maker started working within five minutes.
1 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Arthur from Easthampton, MA
Parts Used:
4318047
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Wrench (Adjustable)
Ice maker was making hollow ice, then no ice
Very simple repair. Ice maker was operating, but not receiving water. Once new valve was in place it works like new.
1 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Patricia from Buena Park, CA
Parts Used:
MHIK7989
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
The coating in the ice maker was peeling and ice not ejecting properly. The water would over flow over to the ice tray and freez.
Remove the 3 screws and disconect the plug. The wiring harnes on the new Ice Make did not match so I use the wiring harness from my old unit. I pluged the new one in and screwed in the three screws and it was ready. I did have to wait a full 24 hours before the first 8 pieces of ice eject out.
1 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!