HMG19814 Admiral Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Irene from Whitehall, MT
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
No light in frig
We tried repairing with a new switch which was very easy to install but it didn't fix the problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dennis from Lawrenceville, GA
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Light switch which turns on the lights when the door opens went out
This is an easy fix, simply remove and replace. What I was impressed with is that a how to video was provided along with my part. I wish all manufactures would offer this, the video was easy to understand and you had a good view of the operation. Thanks, a job well done.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- stephanie from lakeland, FL
- Parts Used:
- WPW10189190
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
refrigerator was not cooling
my 17 year old son actually repair it ...it took him all about 5 minutes to install the part and put that refrigerator cover back on ...very easy fix and save me a bundle of cash ...thank you very much and I will be doing more business with you
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Sacramento, CA
- Parts Used:
- WP61004888
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Temp in the refrig side was too high. Freezer OK
I unpluged the refrig, removed the shelves and the back panel on the freezer side of the unit. This exposed the fan motor and fan blade. I removed two screws holding the fan unit in place, unpluged the wires connecting the fan unit to power, and then removed two other screws securing the fan motor to the bracket. I removed the fan motor blade from the old unit and installed it on the new fam motor. I replaced the fan unit into the bracket, pluged the wires back into the fan motor and secured the motor to the refrig. Replaced the back panel and shelves, pluged the refrig into the wall.....easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dora from Rock Island, IL
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
light would come on and off
Viewed the viedo - it showed what to do
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Henry from Newland, NC
- Parts Used:
- WP68601-6
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Refrigerator was running very cold
Unscrewed the right control knob. Removed the left temperature control knob (there is no screw holding it), removed one screw to rear of small panel then pried open from the rear of the small panel, there are two plastic tabs in front of the small panel holding it in place. Unscrewed the failed control unit and replaced it with the new one. Replaced the small panel and screw then the left side control knob, making sure of the alignment in the "off" position as the knob has to be pressured into a clamp arrangement on the cold control thermostat. Re-screwed the right knob into place, as well.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Don from Laramie, WY
- Parts Used:
- W11384469
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
Switch didn't work
followed the video as instructed. Saved two repairman calls, one to find the problem, one to install. Net savings was about $130.00
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- JOHN from TWINSBURG, OH
- Parts Used:
- 4318047
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers, Wrench (Adjustable)
Water Was Not Reaching The I Ce Maker
Disconnect ac power line, disconnect power line going to the water valve. Turn water off atthe cockvalve. Disconnect water line to valve. Disconnect plastic tubing going in the valve. If plastic is old you may have to replace it to keep from leaking at the quick connect coupling. Connect water line and plastic tubling to new valve, connect power clips to new valve. Plug in the refrigertor and turn on water at the cock valve and your good to go
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Denise from Manchester, NH
- Parts Used:
- 4318047
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers, Wrench (Adjustable)
Ice Maker was overflowing into ice bin when filling
Thought we'd try the Water Valve before replacing the ice maker. Ordered new valve online on Saturday, it arrived on Tuesday. I installed it twice in less than 30 mins. Had a little leak the 1st time, so I uninstalled it, trimmed up the water line with a box cutter and reinstalled without issue. No leak this time. Easy Peasy. My husband said "You're good, you." :)
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joseph T. from Morgantown, WV
- Parts Used:
- W11384469
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Light switch went bad
Simply stick a putty knife between the switch and refrig wall. Pop out old swith, remove both wires by pulling off switch by terminals. Throw switch out. Put wires on new switch and push into slot and all done. Nothing to it! Took me 5 minutes if th
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Grant from Alexandria, VA
- Parts Used:
- 8009
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Light bulb failure
Received the part the day after ordering. Appreciated the quick service and repair took less than a minute.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Paula from Rush, NY
- Parts Used:
- W11384469
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
light switch sticking
I watched the video and thought "I can do this". Made some notes and then proceeded to remove the old switch and replace with the new one. Thank you.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Louis from Beloit, WI
- Parts Used:
- W11384469
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- Less than 15 mins
Light did not come on (bad bulb!) on TC18KL
I have never before seen a bulb with the filament intact not light. If the bulb's filament seems intact, screw the bulb into a known working lamp and see if it lights. When screwing it back into the socket in the fridge, it takes a bit of extra effort to fully seat (until it does, it won't light!). For replacing the switch, I unplugged the unit, used a paint scraper and worked it under the switch bezel from the right side. A bit of moxie, and the switch came out. The replacement switch had a different spade contact spacing than the original. I used a pair of scissors to cut the rubber bridge between the two switch wire connectors so I could connect to the new switch. In the end, it turned out to be the bulb. NOTE: The Model TC18KL is _not_ listed! What I finally found that the number "P7803211WL" on the sticker is actually a manufacturing code. Found this out by searching, and Sears' part search came up with matches.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Edward from Sykesville, MD
- Parts Used:
- WP60106-35
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers, Socket set, Wrench set
Freezer and Refrigerator not cooling properly
Researched this problem on the web. Disassembled the main refrigeration unit (slide out freezer floor panel). The cooling coils were completely iced up. Thawed overnight. Tested the coil thermostat with a multimeter and discovered it worked. Note that the activation temp on this thermostat is 15 degrees Fahrenheit so the ice-water bath test on many web videos will NOT work. My test was in another refrigerator freezer compartment (everyone has two, right?). When the temperature went below 15 and stayed there for 15 minutes, the thermostat opened the circuit. Further investigation revealed that the defrost heater was burnt and shorted. Replaced the defrost heater only to discover that the defrost timer was also broken. After replacing the defrost timer and testing each component thoroughly, the refrigerator is back in service. Freezer maintains about 8 F and the main refrigerator stays at about 36. The unit cycles off properly and the defrost timer is correctly initiating a defrost cycle. Further, when the defrost heater is cycled on, the thermostat correctly shuts it off once the coils are defrosted. Watch the youtube videos. Find your parts and note their specifications so you can test them properly. And good luck.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Metuchen, NJ
- Parts Used:
- 4318047
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers
New Part Was Different From Previous Part
First attempt was difficult. Part was different and instructions applied to previous part that did not have quick connect. Not clear where quick connect was to be used. Result no ice!second attempt used quick connect in reverse connections and now have plenty of ice. Combination of change in part appearence from previous one ,and different from instructions included with new part, resulted in confusion in installation. In the long run, it worked out well.
Was this instruction helpful to you?
Thank you for voting!