Customer:
Gena from ROSICLARE, IL
Parts Used:
1B71961H
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Broken Tray ,Glass
Received my replacement Tray,Glass in only 2 days. Opened it and placed it in the Microwave. Yep, it was that easy!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Douglas from Missoula, MT
Parts Used:
6010W2P008A
Difficulty Level:
A Bit Difficult
Total Repair Time:
More than 2 hours
Tools:
Screw drivers
House wiring failure caused excessive voltage to microwave
Disassembled control panel and checked power transformer windings. Primary winding fried. Patched power to magnatron transformer to make sure it was ok. Removed power transformer and checked diodes and transistors on board which were ok. Installed new transformer and reassembled control panel to microwave. Checked functions.
Was this instruction helpful to you?