Customer:
Michael from North Miami Beach, FL
Parts Used:
WB24T10058
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Dual Burner was not turning off or turning on by itself
Pulled the top back panel off, pulled off burner control knob, removed 2 screws which released switch, removed 5 wires from switch and connected them to new switch (pulled off faily easily). Reconnected the 2 screws to range and pushed knob back on. Replaced panel and reconnect the electric. Now works as it should.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Estero, FL
Parts Used:
WB24T10058
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Pliers, Screw drivers
Dual burner on range stopped working.
Changed out the burner with a new replacement and it still didn't work. The socket on the old burner had a burn mark on it. The infinite switch operated sloppy not crisp like the other burners.Ordered a replacement online. Moved the range away from wall and cabinet and shut off electric at panel box. Removed upper back panel. removed switch knob and 2 screws holding switch. Compared electrical connections of both switches and saw that they were different. Read instructions which were included with new switch and found diagram for connecting old lead to new lead correctly. After all leads were connected, remounted new switch powered up and tested OK.
Was this instruction helpful to you?
Thank you for voting!